Instruction Manual On-board type 2.2 Overcurrent Protection 1 Pin Terminal Configuration ¡ Overcurrent Operation An overcurrent protection circuit is built-in and activated at 105% Table 1.1 Pin Terminal Configuration and Functions of the rated current or above. It prevents the unit from short circuit Pin Terminal and overcurrent for less than 20 seconds.
Instruction Manual On-board type Output Table 2.2 Specification of Remote ON/OFF +Vout External Resistor Voltage Level of the pin terminal RC (V SU/SUC3, SU/SUC6 Output Open or Short or 0V[V [0.3V Load External VR 2.0V[V [9.0V External Resistor ¡ Please keep the voltage level of the pin terminal RC (V ) at 9.0V -Vout or below.
Table 3.2 Recommended Capacitance of External Capacitor on the Output Side [ F] In such case, connecting Ci to the input pin terminal is recom- Model mended. SU/SUC1R5 SU/SUC3 SU/SUC6 SU/SUC10 Output Voltage(V) ¡ If you use an aluminum electrolytic capacitor, please pay attention 1 - 100...
Instruction Manual On-board type 4 Series/Parallel 5 Input Voltage/ Operation Current Range 4.1 Series Operation ¡ If you use a non-regulated power source for input, please check and make sure that its voltage fluctuation range and ripple voltage ¡ You can use the power supplies in series operation by wiring as do not exceed the input voltage range shown in specifications.
Instruction Manual On-board type 6.2 Automatic Mounting (TYPE: B) (2) Flow Soldering : 260C 15 seconds or less (3) Soldering Iron : maximum 360C 5 seconds or less ¡ To mount SU series automatically, use the transformer area near the center of the PCB as a pickup point. To mount SUC series au- 6.4 Stress to Pin Terminals tomatically, use the central area of the case as a pickup point.
Instruction Manual On-board type (3) Temperature Measuring Points in the case of Forced Air Cool- (2) In the case of Forced Air Cooling (1m/s) ing (1m/s) 1 SU1R5 ¡ In the case of forced air cooling, please have sufficient ventilation to keep the temperature of point A in Fig.8.3 at 105C or below.
Instruction Manual On-board type 8.3 SU/SUC6 Derating Curve (3) Temperature Measuring Points in the case of Forced Air Cool- ing (1m/s) ¡ If you derate the output current, you can use the unit in the tem- 1 SU6 perature range from -40C to the maximum temperature shown ¡...
Instruction Manual On-board type (2) In the case of Forced Air Cooling (1m/s) 9 Peak Current (Pulse Load) ¡ If a load connected to a converter is a pulse load, you can provide a pulse current by connecting an electrolytic capacitor externally to the output side.
Page 12
Instruction Manual On-board type ¡ When Using a Non-regulated Power Source ¡ To Use a Dual Output Type *Dual output type is typically used in the following manner. +15V +Vin +Vout +Vin +Vout +12V -Vin -Vout -15V -Vin -Vout -12V ¡...
Instruction Manual On-board type 11 Deliver Package Information ¡ These are packed in a tray. (Fig.11.1) Please order ”SU OOOOO BP” for pallet type packaging. Table 11.1 Capcity of the pallet (pcs/pallet) SU1R5 30max 30max 20max SUXXXXXX SU10 20max In case of fractions, the units are stored in numerical order. OOOO OOOO (C12)