Davco SHOP PRO ST Technical Manual page 11

Table of Contents

Advertisement

E CAUTION!: To prevent damage to fuel
system components, make sure pressure
regulator handle is in 50 PSI position
when servicing MaxxForce
engines.
50
PSI
1 .
Connect the Shop Pro to a power source .
2 .
Attach the green Voss adapter to the suction hose
(green) .
3 .
Connect the red Voss adapter to the pressure hose (red) .
4 .
Disconnect the fuel supply line from the FUEL OUT port .
DAVCO Technology, LLC
PRIMING WITH REGULATOR SETTINGS OF 50 PSI
11, 13 and 15
®
1600 Woodland Drive, Saline, MI 48176-1629
WITH 50/80 PSI PRESSURE REGULATOR
5 .
Connect the green Voss adapter to the Fuel Pro inlet
fitting . (Item 3) .
6 .
Connect the engine fuel supply line (Item 1) to the red
Voss adapter (Item 2) .
E CAUTION: USE CARE WHEN CONNECTING VOSS
FITTINGS TO AVOID ACCIDENTAL BREAKAGE.
7 .
Open the ball valves (Items 1 and 2) .
800-328-2611
9
SHOP PRO
TECHNICAL MANUAL
www.davco.com
F1321 REV E
ST
®