L&R 4002 Series Operator's Manual

Ultrasonic generator

Advertisement

4002 SERIES
ULTRASONIC GENERATOR
OPERATOR'S MANUAL
L&R Manufacturing Company
577 Elm Street
Kearny, NJ 07032-3604 USA
CN 80406 Rev. E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4002 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for L&R 4002 Series

  • Page 1 4002 SERIES ULTRASONIC GENERATOR OPERATOR'S MANUAL L&R Manufacturing Company 577 Elm Street Kearny, NJ 07032-3604 USA CN 80406 Rev. E...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SYSTEM DESCRIPTION OPERATION, WARNINGS AND CAUTIONS SPECIFICATIONS INSTALLATION PROCEDURE DIGITAL TIMER OPERATING INSTRUCTIONS SYSTEM CONTROL REPLACEMENT PARTS LIST WARNING: If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired.
  • Page 3: System Description

    SYSTEM DESCRIPTION The 4002 Ultrasonic Generator is a modular design, consisting of a main controller housing and able to accept from one to three generator boards. Each board is capable of driving a separate immersible transducer module, or a group of transducers bonded to a tank. Generator modules can be individually or simultaneously operated with timer.
  • Page 4: Specifications

    SPECIFICATIONS PRODUC MODEL Voltag BOARD TOTAL CURRENT Main FUSE Data NUMBER SECTIONS POWER REQUIREMENTS CODE T10.0A/250V 17677 600 W 5.1A 110V 4002-1/6 T5.0A/250V 17678 600 W 2.7A 230V T20.0A/250V 17685 1200 W 10.2A 110V 4002-2/6 T10.0A/250V 17686 1200 W 5.4A 230V T30.0A/250V 17693 1800 W...
  • Page 5: Installation Procedure

    ENVIRONMENTAL: Allow 3” behind generator for cable, connectors and air flow.  Generator to be located in a dry location, 0-35°C, RH 96% Non-Condensing  non-corrosive atmosphere below 2000 M altitude. Units can be stacked or stand side by side (min. 2” between sides). DO NOT ...
  • Page 6 After applying an appropriate AC to the power input terminals, the display will be blank and the beeper will beep for ¼ second giving the user notification that the timer is now activated. The units’ default is in Minute [Mode]. Setting Time of Day - Push and hold the button [SET/DISPLAY] for 1 second, the unit will default the time to 12:00am and enter the ‘Clock Set’...
  • Page 7: System Control

    SYSTEM CONTROL iindividual section ON/OFF power switch (not applicable on Single Generator). This switch is capable of turning the power TIMER on or off for a single generator section independent of the remaining sections. WATTMETER Ultrasonics On - Indicator light This pilot light is an indicator of the SWEEP RATE CONTROL...
  • Page 8: Replacement Parts List

    REPLACEMENT PARTS LIST DESCRIPTION FUSE HOLDER 30129 FUSE 5 AMP 31591 FUSE 10 AMP 30126 FUSE 15 AMP 32291 FUSE 20 AMP 30128 FUSE 30 AMP 31913...
  • Page 9 Please Record: Serial # ___________ Order Date ________ One Year Limited Warranty L&R Manufacturing Company warrants this product for a period of one year from the date of purchase to be free of defects in material and workmanship. Machine will be repaired free of charge to the customer during the warranty period.
  • Page 10 REVISION HISTORY C/N 80406 REVISION ECN# DESCRIPTION APPROVED DATE 8294 SEE ECN J.P.M. 01/22/2007 8316 REVISED SHEET 4, J.P.M. 01/24/2007 SEE ECN 8316. 8725 REVISED SHEET 5 J.P.M. 11/17/2010 2000 M was 2000 Ft...