OXYGEN 3000 · User Manual · ENG SUMMARY SUMMARY ................................... 2 SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA ..................... 5 PREFACE 5 SAFETY WARNINGS ................................6 CONSIGNES DE SÉCURITÉ IMPORTANTES ..........................8 ISTRUZIONI IMPORTANTI PER LA SICUREZZA ........................10 WICHTIGE SICHERHEITSHINWEISE ............................13 INSTRUCCIONES IMPORTANTES DE SEGURIDAD ........................
Page 3
OXYGEN 3000 · User Manual · ENG SMART KEY / JINGLE BUTTONS* ......................... 49 DISPLAY 7’’ TFT AND CONTROL BUTTONS ......................50 A. COLOR DISPLAY 7’’ - 800X480 RESOLUTION ........................50 B. BUTTONS FOR THE MENU NAVIGATION ..........................51 C. ENCODER FOR THE MENU NAVIGATION ..........................51 D.
Page 4
OXYGEN 3000 · User Manual · ENG COMMUNICATIONS ................................83 TCP-IP ......................................83 TIME&DATE....................................83 TIME ZONE ....................................84 ACCESS CODE ..................................84 LIGHT & DISPLAY ................................. 85 SMART KEYS ..................................86 ONAIR TRIGGERS................................. 86 4. SERVICE ................................87 CONFIGURATION ..............................87 SOFTWARE ................................
OXYGEN 3000 · User Manual · ENG SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA SAFETY WARNINGS CONSIGNES DE SÉCURITÉ IMPORTANTES ISTRUZIONI IMPORTANTI PER LA SICUREZZA WICHTIGE SICHERHEITSHINWEISE INSTRUCCIONES IMPORTANTES DE SEGURIDAD (Rel. 1.6) PREFACE For your safety and to prevent the warranty from being accidentally invalidated, please read carefully all the texts marked with the Warning Symbols The information contained in this manual is subject to change without notice and does not constitute a commitment by the seller.
OXYGEN 3000 · User Manual · ENG SAFETY WARNINGS The installation and servicing instructions in this manual are for use by qualified personnel only. Read All Instructions. All safety and operating instructions must be read before operating the product. They also must be retained for future reference, as it contains many useful hints for determining the best combination of equipment settings for Yr particular application.
Page 7
OXYGEN 3000 · User Manual · ENG This symbol alerts you to the presence of dangerous voltage inside the closure – voltage that may be sufficient to constitute a risk of shock. Do not perform any servicing other than that contained in the operating instructions. Refer all servicing to qualified personnel.
OXYGEN 3000 · User Manual · ENG CONSIGNES DE SÉCURITÉ IMPORTANTES Lire ces consignes. Conserver ces consignes. Observer tous les avertissements. Suivre toutes les consignes. Ne pas utiliser cet appareil à proximité de l’eau. Ne pas obstruer les ouvertures de ventilation. Installer en respectant les consignes du fabricant. Ne pas installer à...
Page 9
OXYGEN 3000 · User Manual · ENG Ce symbole indique la présence d'une tension dangereuse dans l'appareil constituant un risque de choc électrique. Ce symbole indique que la documentation fournie avec l'appareil contient des instructions d'utilisation et d'entretien importantes. Avant de modifier le commutateur de changement de tension ou replacer le fusible il faut débrancher l’appareil de la prise électrique.
OXYGEN 3000 · User Manual · ENG ISTRUZIONI IMPORTANTI PER LA SICUREZZA Leggere le presenti istruzioni. Conservare queste istruzioni. Osservare tutte le avvertenze. Seguire scrupolosamente tutte le istruzioni. Non usare questo apparecchio in prossimità di acqua. Non ostruire alcuna apertura per il raffreddamento. Installare l’apparecchio seguendo le istruzioni. Non installare l'apparecchio accanto a fonti di calore quali radiatori, aperture per l'afflusso di aria calda, forni o altri apparecchi (amplificatori inclusi) che generino calore.
Page 11
OXYGEN 3000 · User Manual · ENG Il prodotto deve essere utilizzato solo se integro e non danneggiato. Se il prodotto è stato sottoposto a forti urti o fosse venuto a contatto con liquidi è necessario contattare l'assistenza prima di accenderelo. Il prodotto non và...
Page 12
OXYGEN 3000 · User Manual · ENG Questo simbolo indica la presenza di alta tensione all'interno dell'apparecchio, che comporta rischi di scossa elettrica. Questo simbolo indica la presenza di istruzioni importanti per l'uso e la manutenzione nella documentazione in dotazione all'apparecchio. Non sostituire il fusibile o cambiare la tensione di alimentazione senza aver prima scollegato il cordone di alimentazione.
OXYGEN 3000 · User Manual · ENG WICHTIGE SICHERHEITSHINWEISE Diese Hinweise LESEN. Diese Hinweise AUFHEBEN. Alle Warnhinweise BEACHTEN. Alle Anweisungen BEFOLGEN. Dieses Gerät NICHT in der Nähe von Wasser verwenden. KEINE Lüftungsöffnungen verdecken. Gemäß den Anweisungen des Herstellers einbauen. Nicht in der Nähe von Wärmequellen, wie Heizkörpern, Raumheizungen, Herden oder anderen Geräten (einschließlich Verstärkern) installieren, die Wärme erzeugen.
Page 14
OXYGEN 3000 · User Manual · ENG Dieses Symbol zeigt an, dass gefährliche Spannungswerte, die ein Stromschlagrisiko darstellen, innerhalb dieses Geräts auftreten. Dieses Symbol zeigt an, dass das diesem Gerät beiliegende Handbuch wichtige Betriebs- und Wartungsanweisungen enthält. Vor Änderung der Netzspannung oder Sicherungswechsel Netzkabel trennen.
OXYGEN 3000 · User Manual · ENG INSTRUCCIONES IMPORTANTES DE SEGURIDAD LEA estas instrucciones. CONSERVE estas instrucciones. PRESTE ATENCION a todas las advertencias. SIGA todas las instrucciones. NO utilice este aparato cerca del agua. NO obstruya ninguna de las aberturas de ventilación. Instálese según lo indicado en las instrucciones del fabricante.
Page 16
OXYGEN 3000 · User Manual · ENG Este símbolo indica que la unidad contiene niveles de voltaje peligrosos que representan un riesgo de choques eléctricos. Este símbolo indica que la literatura que acompaña a esta unidad contiene instrucciones importantes de funcionamiento y mantenimiento. Antes de cambiar la alimentacion de voltaje o de cambiar el fusible, desconecte el cable de alimentacion.
OXYGEN 3000 · User Manual · ENG UNPACKING AND INSPECTION Your equipment was packed carefully at the factory in a container designed to protect the unit during shipment. Nevertheless, we recommend making a careful inspection of the shipping carton and the contents for any signs of physical damage. Damage &...
OXYGEN 3000 · User Manual · ENG FIRST INSTALLATION RECOMMENDATIONS POWER SUPPLY CABLE A power supply cable of approx. 2 mt. lengths is supplied with the device, which has a moulded IEC plug attached – this is a legal requirement. The type of plug for the power supply depends on the country in which it is delivered.
OXYGEN 3000 · User Manual · ENG OXYGEN 3000 INSTALLATION NOTE AND FIRST STEP Best setup location The Oxygen 3000 should be installed avoiding direct sunlight, close proximity to radiators and air conditioning, dust, water, and chemicals. Choose a console location that permits a clear view of the indicators on the device and ensures a sufficient heat dissipation of the device.
OXYGEN 3000 · User Manual · ENG INTRODUCTION Oxygen 3000 is the new concept digital console and defines a new standard in the broadcast market. Characterized by an elegant design and compact size, Oxygen 3000 has been designed for both On-Air and Production studios. ...
OXYGEN 3000 · User Manual · ENG 1.4 INPUT CONNECTIONS Aux-In 1. Bluetooth Stereo Input - Mini Jack 3.5mm - Bluetooth Stereo/Mono Input - Wireless – Unbalanced Audio Connection. Smartphone. (it will be out of service if the DANTE* mixer contains the DANTE 2 Stereo digital audio inputs over Ethernet.
OXYGEN 3000 · User Manual · ENG SURFACE 1. INPUT LED METER 2. OUTPUT LED METER 3. CONTROL INPUT CHANNEL 4. SPECIAL FUNCTION BUTTONS 5. MONITORS SECTION 6. SMART KEY / JINGLE BUTTONS 7. DISPLAY 7" TFT AND CONTROL BUTTONS SURFACE |TALKBOX CONNECTIONS...
OXYGEN 3000 · User Manual · ENG 2.1 INPUTS LED METER A. The LED level meters display the audio signal input on the channel (PRE-FAFER). The LED level meters have a 10dB accuracy, from -50 to +10dB. The level is PRE- FAFER, the FADER position has no effect on the displayed level. B.
Page 30
OXYGEN 3000 · User Manual · ENG C. It is possible to select the displayed BUS by pressing the METER button. It is possible to switch the 4 Buses and MONITOR SELECTION sequentially, by a repeated pressing. PFL -> SUB -> AUX-1 -> AUX-2 -> MONITOR SELECTION -> PFL -> SUB… The selected BUS is forcedly displayed when the related LED (PFL/SUB/AUX-1/AUX-2) is on.
OXYGEN 3000 · User Manual · ENG 2.3 CONTROL INPUT CHANNEL A. SET – BUTTON TO SET CHANNEL PARAMETERS. B. CHB – BUTTON FOR THE SOURCE SWITCHING BETWEEN THE PRIMARY SOURCE (A) AND THE SECONDARY (B). C. GAIN – KNOB TO ADJUST THE INPUT SOURCE LEVEL OF THE SIGNAL.
OXYGEN 3000 · User Manual · ENG SET BUTTON To enter in the settings menu and view the channel configuration, press SET. single-clicking: the button starts blinking and shows on the display the configuration menu for the channel. To exit from viewing/setting mode press one of the buttons: (SET, MENU, or ESC). ChB BUTTON For every channel, you can set two different input sources, ChA and ChB.
OXYGEN 3000 · User Manual · ENG GAIN The GAIN knob rotation increases or decreases the input source gain. The GAIN value is associated with the selected source ChA/ChB, not with the physical channel. By switching the source, the gain is always suitable to the connected one. The GAIN value is the latest setting is seated by the knob.
OXYGEN 3000 · User Manual · ENG EQ BUTTON The equalizer is associated with the selected source when a source is selected for a channel also the related and customized equalization is loaded. Press EQ Enable/Disable the equalizer. EQ button reports if the equalizer is ON or OFF by lighting. Press &...
OXYGEN 3000 · User Manual · ENG PGM/SUB/AUX-1/AUX-2 BUTTONS The PGM, SUB, AUX-1, AUX-2 buttons enable or disable the output signal routing on the related BUS, the RGB LEDs under the related button has three different states color: 1) disabled (LED OFF) 2) enabled + Channel ON 3) enabled + Channel MUTE The Different in BUS’s status, it's not associated with the source, like EQ and...
OXYGEN 3000 · User Manual · ENG FADER A command is generated every time the Fader passes through the threshold value: ON - crossing the threshold point from bottom to top. OFF - crossing the threshold point from top to bottom. Differently, from the EQ and the GAIN, the FADER status is not associated with the source, it is associated but with the physical channel.
OXYGEN 3000 · User Manual · ENG ON/START BUTTON ON/START button enable or disable the channel (ON/OFF), the OFF status mutes the channel automatically, and the RGB LEDs under the buttons has three different statuses: 1) LED OFF - OFF status - the channel is MUTE. 2) LED ON in (warm color) - ON status –...
OXYGEN 3000 · User Manual · ENG PFL BUTTON PFL button enables/disables the pre-listen of the channel. When the button’s LED is ON, the pre-listen is enabled on that channel. Differently, from the EQ and GAIN the PFL status is not associated with the source, it’s associated with the physical channel.
OXYGEN 3000 · User Manual · ENG 2.4 SPECIAL FUNCTION BUTTONS OUTPUT BUTTON The OUTPUT button recalls directly the OUTPUTS configuration menu. This button is a SHORTCUT to reach immediately the OUTPUT menu. SURFACE |SPECIAL FUNCTION BUTTONS...
OXYGEN 3000 · User Manual · ENG METER BUTTON The METER button manages the source displayed in the bottom section of the LED METER screen. By pressing METER, you can select the displayed BUS. The repeated pressing of the METER button switches the 4 BUS and the MONITOR SELECTION, sequentially displaying them.
The device is in pairing mode after a fast press (< 1 sec) of the Bluetooth button. It starts to blink in blue color. search for the Oxygen 3000D-XXXX in Bluetooth device and connect with it. Once the device is connected the blue light stops blinking.
OXYGEN 3000 · User Manual · ENG 2.5 MONITORS SECTION CONTROL ROOM SPEAKERS (SPK-CRM) This section is used for the management of the Control Room Speakers. allow you to amplify/attenuate the audio level. The rotary control knobs The loudspeakers audio level goes from 0 to 99 is the maximum allowed level.
Page 43
OXYGEN 3000 · User Manual · ENG EX.: if you need to listen to different output in SPK-CRM Control Room Speakers, select the 2SEL ② mode from the setting and press the SPK button in section (it will show up in warm color), then ④...
Page 44
OXYGEN 3000 · User Manual · ENG When you open the associated source with a CUT function you will see it will MUTE CR Loudspeakers output to prevent LOOP audio and the SPEAKER icon at LCD will start plinking. ATT. (attenuation) MODE: It helps reduce acoustic flux from flowing into the speakers. It possible to decrease the speakers output -40, -30, -20 or -10 dB.
OXYGEN 3000 · User Manual · ENG CONTROL ROOM HEADPHONE (HDP-CRM) This section is used for the management of the HDP. allow you to amplify/attenuate the audio level. The rotary control knobs The headphone audio level goes from 0 to 99 is the maximum allowed level.
OXYGEN 3000 · User Manual · ENG STUDIO – SPEAKERS This section is used for the management of the ST Studio Speakers. allow you to amplify/attenuate the audio level. The rotary control knobs The loudspeakers audio level goes from 0 to 99 is the maximum allowed level.
Page 47
OXYGEN 3000 · User Manual · ENG CUT-ATT-MODE MENU / AUDIO / OUTPUTS / MONITOR / SPEAKER / SPK-STUDIO / CUT-ATT-MODE CUT MODE: it’s allowed the microphone to CUT OFF the audio of control room loudspeakers once the microphone goes to ON. The opening of a microphone channel (if configured appropriately) can generate the closing command of the loudspeakers.
OXYGEN 3000 · User Manual · ENG STUDIO – HEADPHONES SOURCES & LEVEL This section is used for the management of the HDP-STUDIO headphones . allow you to amplify/attenuate the audio level. The rotary control knobs The headphone audio level goes from 0 to 99 is the maximum allowed level.
OXYGEN 3000 · User Manual · ENG TALKBACK – FROM CONTROL ROOM TO THE STUDIO This section is used for the management of the TB “TALKBACK” from the CONTROL ROOM to the Studio. By pressing TB1 it’s possible to speak with the anchorman in the STUDIO from the CONTROL ROOM. By pressing TB2 it’s possible to speak with the GUESTS in STUDIO.
OXYGEN 3000 · User Manual · ENG 2.7 DISPLAY 7’’ TFT CONTROL BUTTONS COLOR DISPLAY 7’’ - 800X480 RESOLUTION The display is used to control the mixer setting and monitor all the parameters and it has its own configuration menu. The display has some parameters that can be changed it like DIMMER and LOGO.
OXYGEN 3000 · User Manual · ENG BUTTONS FOR THE MENU NAVIGATION 1) The MENU button switches from HOME to MENU. With this button, you can recall the mixer configuration menu. >> and << (2) (3) Buttons allow you to move between pages of parameters/functions on the same menu level.
OXYGEN 3000 · User Manual · ENG MENU display parts 1. In this part of the display can see some useful elements and information depending on the location from the MENU. 2. From here you can browse all lists available in the menu. 3.
OXYGEN 3000 · User Manual · ENG 3.1.1 MIC (MIC-1 to MIC-5) Here we can find all Microphones source parameters (MIC-1 to MIC-5) That can manage the five microphones’ inputs like changing the NAME, GAIN, PAL/PAN, PREAMP, PHASE, PHANTOM 48V, and many other functions we going to explain it briefly in below. NAME: This parameter allows the assignment of a LABEL to the various input sources.
OXYGEN 3000 · User Manual · ENG PREAMP: The preamplifier is typically used to amplify signals from analog sensors such as microphones. It allows you to convert a weak signal for sending to a power amplifier or loudspeakers without any noise or distortion. This parameter changes the Input PREAMPLIFIER.
Page 55
OXYGEN 3000 · User Manual · ENG These are graphic equalizers that provide an adjustable band between 22.4 Hz and 20 kHz. A master volume slider compensates for changes in volume caused by the equalization. An equalizer allows the sound in specified frequency bands to be amplified or reduced, to adjust the quality and character of the sound.
Page 56
OXYGEN 3000 · User Manual · ENG EQ PRESET: This function is useful to save and recall the equalizer settings. These settings are saved at the internal memory and it is not exportable. SNAPSHOT: it’s able to save ten different EQ PRESET by select the position of the new save from 1 to 10 before save it.
Page 57
OXYGEN 3000 · User Manual · ENG BASS, BASS-MID, MIDDLE, MID-HIGH, HIGH: In OXYGEN 3000 the Parametric equalizers allow the adjustment of multi-band frequency equalizers which allow you to control the three primary parameters: AMPLITUDE, CENTER FREQUENCY, and BANDWIDTH. The amplitude of each band can be controlled by the GAIN knob. The center frequency can be shifted by the FREQUENCY knob.
OXYGEN 3000 · User Manual · ENG BAL/PAN: This parameter changes the Input BAL/PAN. The parameter has a 1.0 dB step. N.B.: When you adjust the BAL/PAN parameter, you have a real-time change of the parameter value and the real-time perception of the BAL/PAN change. The Graphics will become white to indicate the parameter change, and it will become yellow again after the confirmation.
OXYGEN 3000 · User Manual · ENG PHANTOM 48V: This option allows you to turn the phantom power 48V ON/OFF for use with microphones (if the microphone requires it, such as a condenser microphone). The Phantom is shown in the channel Set Panel.
Page 60
OXYGEN 3000 · User Manual · ENG The opening of a microphone source (if configured appropriately) can generate the closing command of the loudspeakers. That is possible to choose one or more source to cut the loudspeaker. When you open the associated source with an SPK-CUT function, you will see it’s will MUTE CR (Control Room) Loudspeakers output and the SPEAKER icon at LCD will start plinking.
Page 61
OXYGEN 3000 · User Manual · ENG 3.1.1.11 AUX1, AUX2: From this section, OXYGEN gave you the possibility to set AUX-1 and AUX-2 to be (POST FADER, PRE-Fader, or PRE FADER ALWAYS ON) this choice is of every single channel. When you set AUX-1 and AUX-2 to be FADER.
Page 62
OXYGEN 3000 · User Manual · ENG 3.1.1.13 DYN. COMP.: Dynamic range compression (DRC) or simply compression is an audio signal processing operation that reduces the volume of loud sounds or amplifies quiet sounds thus reducing or compressing audio signals in DYNAMIC RANGE. Compression is commonly used in sound recording and reproduction, broadcasting, live sound reinforcement, and some instrument amplifiers.
Page 63
OXYGEN 3000 · User Manual · ENG 3.1.1.14 F1 MODE: This feature gives the ability to change the action of the F1 button. NONE: no action. TB: By pressing F1 can talk privately with the studio in Talkback (TB). DUCKING: to activate or deactivate the DUCKING on this source. 3.1.1.15 BUTTON-LIGHT, FADER BAR LIGHT: Button light LED it’s to indicate the channel status.
OXYGEN 3000 · User Manual · ENG 3.1.2 MIC-5 INPUT / TELCO INPUT To use an external telephone hybrid, you must change the MIC-5 to set it as a TELCO input. The telco input channel controls the connection to a telephone balance unit (or external hybrid). It has one balanced line-level mono input on XLR.
Page 65
OXYGEN 3000 · User Manual · ENG In this case, just goes to the intended channel source and change it from MIC-5 to empty or any other choice. To use the internal hybrid in OXYGEN, connect the telephone line to the console RJ11 LINE port and the telephone set to the RJ11 SET port in the console.
OXYGEN 3000 · User Manual · ENG 3.1.3 MONO-1 to MONO-6 Line-1, Line-2, Line-3 3 Stereo Input (L/R) / 6 Mono - XLR Female - Balanced Audio Connection (50KΩ). » To browse the MONO source pages just click on the Next button ( ) in the MIC/MONO page as the next figure.
OXYGEN 3000 · User Manual · ENG To change the source type from MONO to STEREO or on contrary you need to follow these steps: - MENU: MAIN / AUDIO / SETTING / INPUT MODE 3.1.4 STEREO You can set Input Stereo source parameters from the MENU: AUDIO / INPUTS / STEREO PUSH/RUTATE the knobs as in the following steps.
OXYGEN 3000 · User Manual · ENG STEREO-1 to STEREO-7 Here we can find all STEREO source parameters (STEREO-1 to STEREO-7) That can manage our 7 inputs like changing the NAME, GAIN, PAL/PAN, EQ, AUX-1, AUX-2, BUTTON LIGHT, and FADER BAR LIGHT. OXYGEN gave you the possibility to set AUX-1 and AUX-2 to be POST-Fader or PRE-Fader, this choice is of every single channel.
OXYGEN 3000 · User Manual · ENG 3.1.6 TEL/BT These three different kinds of implementations were been grouped all together. In fact, they have similarities on the source side. 3 kind of telephone connection is available on OXYGEN Digital console: TELCO (external telephone ...
OXYGEN 3000 · User Manual · ENG Telephone Hybrid The built-in telephone hybrid allows direct connection of a telephone line POTS/PSTN on RJ-11C. The audio is processed via DSP that delivers state-of-the-art audio processing. TLC commands are available on a SubD connector with Hook and Ring interface for an external telephone hybrid.
OXYGEN 3000 · User Manual · ENG When you want to speak privately with a caller just press the PFL in the TELEPHONE line channel. PRIVATE MIC is the input dedicated to the communication with the caller. Like the Talkback, it is not ruled by the ON/START button or by the fader level.
OXYGEN 3000 · User Manual · ENG 3.1.7 DIGITAL OXYGEN Digital Mixing Console has included digital audio I/O sources. By the digital audio, it can connect any digital audio source via AES/EBU, USB, Dante. AES/EBU Stereo Input - XLR Female - Balanced Digital Connection (110Ω) USB-1, USB-2 Two USB audio interface The USB audio interface allows to directly connect the PC to the Oxygen console, with no need for...
Page 73
OXYGEN 3000 · User Manual · ENG To set the parameters correctly, we have to leave the output/playback as default (48000 Hz). For the input/recording, we have to change the frequency to (44100 Hz). DANTE 1, DANTE 2 DANTE AUDIO-OVER-IP CONNECTIVITY (Optional) Dante option (compliant with AES67) provides an Ethernet connection for 2 Stereo Input and 2 Stereo Output, with independent and dedicated Level Control and Sample Rate Conversion.
OXYGEN 3000 · User Manual · ENG 3.2 AUDIO/OUTPUTS OXYGEN Digital console is coming with variant audio outputs connectors like XLR, JACK, USB, and RCA to give you maximum flexibility with your instruments and your project cabling. With all those functions you can save your time and your money.
OXYGEN 3000 · User Manual · ENG 3.2.2 MONITORS SPK-CRM & SPK-STUDIO • This section is used for the management of the loudspeakers. • The rotary control knobs allow you to amplify/attenuate the audio level. • The loudspeakers audio level goes from 0 to 99 is the maximum allowed level. Can set the maximum level by going to this page: MENU: MAIN / AUDIO / OUTPUTS / MONITOR / SPEAKER...
Page 76
OXYGEN 3000 · User Manual · ENG EX.: if you need to listen to different output in SPK-CRM Control Room Speakers, select the 2SEL mode ② from the setting and press the SPK button in section (it will show up in warm color), that press any ④...
Page 77
OXYGEN 3000 · User Manual · ENG ATT. (attenuation) MODE: It helps reduce acoustic flux from flowing into the speakers. It possible to decrease the speakers output -40, -30, -20 or -10 dB. EX.: If we want to reduce the sound coming out of the speakers by 40 dB less than the current value, then we have to choose -40.
OXYGEN 3000 · User Manual · ENG HDP (headphone) CRM, STUDIO & GUEST This section is used for the management of the headphone. • The rotary control knobs allow you to amplify/attenuate the audio level. • The headphone's audio level goes from 0 to 99 is the maximum allowed level. Can set the maximum level by going to this page: MENU: MAIN / AUDIO / OUTPUTS / MONITOR / HEADPHONES...
OXYGEN 3000 · User Manual · ENG 3.2.3 TONE GEN. ( TONE GENERATOR ) OXYGEN Digital Console comes with a built-in audio tone generator. The tone range is 30 Hz - 20 kHz and you can select it by following these steps: - MENU: MAIN / AUDIO / OUTPUTS / TONE GEN.
OXYGEN 3000 · User Manual · ENG 3.3 SETTINGS INPUT MODE Here we can choose the mode of input sources and we can each one of them like STEREO or 2 MONO. Also, we can change the MIC-5 input to the TELCO input by following these steps: - MENU: MAIN / AUDIO / SETTINGS / INPUT MODE.
OXYGEN 3000 · User Manual · ENG SNAPSHOT This function is useful to save and recall the settings. These settings are saved at the internal memory and it is not exportable. SNAPSHOT: it’s able to save ten different PRESETS by select the position of the new save from 1 to 10 before save it.
OXYGEN 3000 · User Manual · ENG 3.4 GENERAL SET. GPIO Here we will talk about only the physical GPIO connections. You can find the GPIO over IP in the TELCO part. OXYGEN is coms with two SUB-D 9pin (DE-09) as a connector of general-purpose input/output (GPIO).
OXYGEN 3000 · User Manual · ENG COMMUNICATIONS From the GENERAL SET part of the menu, you can set the communication parameters like IP, DNS, Date & Time, Time zone, NTP server. The high flexibility in OXYGEN Digital console design gives you the full ability to set this terrific console as you like and as your audio projects are needed.
OXYGEN 3000 · User Manual · ENG TIME ZONE From this parameter, you can set for the TIME ZONE. You can set for the right Offset to the UTC time. Network Time Protocol. This section contains all the settings related to NTP features. it is, in fact, possible to connect the device to an NTP server, and in this way, the device will synchronize its own date and time with the server.
OXYGEN 3000 · User Manual · ENG LIGHT & DISPLAY From the following menu, you can set the display light and the led brightness. BUTTON LIGHT in this section can set the light intensity of buttons. Also, it can set a different color for MUTE, PFL, and MENU.
OXYGEN 3000 · User Manual · ENG The Oxygen console allows you to set and manage 2 different kinds of outcoming IP commands: The first SMART KEY kind could be managed by Oxygen Smart Keys. the second TRIGGER kind could be managed by OXYGEN channel sliders and related ON/OFF buttons.
OXYGEN 3000 · User Manual · ENG 4. SERVICE 4.1 CONFIGURATION One of the characteristics of OXYGEN is that all settings can be saved on an external memory stick and can be called again when needed, and the settings can also be exported from one mixer to another.
OXYGEN 3000 · User Manual · ENG 4.2 SOFTWARE UPGRADE MIXER FIRMWARE UPGRADE must connect the OXYGEN to the internet. To do this using the DHCP or static IP address, go to: MENU / SERVICE / COMMUNICATIONS / TCP-IP / ADDRESS-1 or 2 / DHCP Active it by selecting (ON) or set the static IP that is given by your IT-MAN.
OXYGEN 3000 · User Manual · ENG B. VERSION FIRMWARE From the following section, you can read the parameters related to the firmware version. 4.3 LOGS the log file is a file that records either events that occur in an operating system or other software runs.
OXYGEN 3000 · User Manual · ENG TALKBOX CONNECTIONS AND FUNCTIONING TALKBOX CONNECTIONS AND FUNCTIONING |WEB LOGIN...
Page 91
OXYGEN 3000 · User Manual · ENG On the OXYGEN 3000 DIGITAL Console, it is possible to connect a maximum of 4 Talk boxes. Every Talk Box is physically connected with a Mixer MIC-source. MIC2-> TB2 MIC3-> TB3 MIC4-> TB4 MIC5->...
Page 92
OXYGEN 3000 · User Manual · ENG TALKBOX CONNECTIONS AND FUNCTIONING |WEB LOGIN...
OXYGEN 3000 · User Manual · ENG PINOUT OF CONNECTIONS PINOUT OF CONNECTIONS |WEB LOGIN...
Page 94
OXYGEN 3000 · User Manual · ENG Analog Balanced Stereo Inputs Connector XLR Balanced – EMI Suppressed Input Impedance 10Kohm Nominal Input Level (sensitivity) 0dBu Max Input Level (clipping point) +18,5dBu A/D conversion 24 bit / 48 Khz Frequency response +/-0,5dB from 20Hz to 20kHz Signal to Noise Ratio (referred to peak level) >100dB...
Page 95
OXYGEN 3000 · User Manual · ENG A/D conversion 24 bit / 48 Khz Signal to Noise Ratio (referred to peak level) >90dB THD+N <0,01% Analog Gain Adjustable +0 ÷ +60dB (3dB step) Phantom Power +48V Analog Balanced Telco Input (shared with MIC5, mutually exclusive) Connector XLR Balanced –...
Page 96
OXYGEN 3000 · User Manual · ENG Max Output Level (clipping point) +19dBu D/A conversion 24 bit / 48 Khz Signal to Noise Ratio (referred to peak level) >90dB Stereo Separation (referred to peak level) >80dB THD+N <0,05% Analog Balanced Talkbox Outputs Connector RJ45 balanced –...
Page 97
OXYGEN 3000 · User Manual · ENG Audio Sample Rate 32/44.1/48KHz with aSRC Resolution 24 bit Dynamic Range (Converter Values) 124dB Digital Output Connector Balanced on 1 XLR – EMI Suppressed Input Impedance 110Ω Standard AES3 Audio Sample Rate 48KHz Resolution 24 bit Dynamic Range (Converter Values)
Page 98
OXYGEN 3000 · User Manual · ENG Nominal Delay (analog input to analog 0,7ms output) GPIO Inputs/Outputs 12 GPI / 10 GPO Communication Port 2xUSB type-A, 2xUSB type-B , 1xLAN, 1xHDMI Operating Temperature 0°C ÷ 40°C PSU (optionally redundant) Power Supply 90-260 Vac / 47-63 Hz 45W Dimensions Dimensions (W;...
OXYGEN 3000 · User Manual · ENG WEEE DIRECTIVE – INFORMATIVA RAEE In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this electrical product must not be disposed of as unsorted municipal waste. Please dispose of this product by returning it to the point of sale or to your local municipal collection point for recycling.
OXYGEN 3000 · User Manual · ENG kommunalt avfall. Bortskaffa den i stället genom att lämna in den på försäljningsstället eller din lokala återvinningsstation. EU:n sähkö- elektroniikkalaiteromudirektiivin (2002/96/EY) mukaisesti tätä elektroniikkalaitetta ei saa laittaa lajittelemattoman yhdyskuntajätteen sekaan. Hävitä laite palauttamalla se ostopaikkaan tai viemällä se elektroniikkaromun keräyspisteeseen. De acordo com a Directiva Europeia 2002/96/EC sobre resíduos sólidos de equipamento eléctrico e electrónico (WEEE), este produto eléctrico não pode ser deitado fora juntamente com o lixo municipal indiferenciado.
Manufacturer: AXEL TECHNOLOGY S.r.l. Company title: VIA C. DI SABBIUNO 6/F - 40011 ANZOLA EMILIA - BOLOGNA ITALY DECLARES UNDER ITS OWN RESPONSIBILITY THAT THE FOLLOWING EQUIPMENT MODEL: OXYGEN 3000D DESCRIPTION: Broadcast digital Console. IS COMPLIANT To the requirements and all characteristics enacted from Community Directive: 2014/30/UE “EMC”...
Nome Fabbricante: AXEL TECHNOLOGY S.r.l. Ragione Sociale: VIA C. DI SABBIUNO 6/F - 40011 ANZOLA EMILIA - BOLOGNA ITALY DICHIARA SOTTO LA PROPRIA RESPONSABILITÀ CHE IL PRODOTTO MODELLO: OXYGEN 3000D DESCRIZIONE: Console Broadcast digitale. RISPETTA i requisiti essenziali e tutte le caratteristiche richiamate dalla Direttiva comunitaria: 2014/30/UE “EMC”...
Need help?
Do you have a question about the Oxygen 3000D and is the answer not in the manual?
Questions and answers