PRODUCT INFORMATION

Description

The Franklin Electric Inline 400 Pressure Boosting System provides consistent water pressure boosting in
residential and small commercial applications that suffer from low water pressure or demand-based fluctu-
ating water pressure. When added to the existing water supply, the Inline 400 senses fluctuating water
pressure, and automatically increases pressure throughout the system.
The Inline 400 is equipped with a flow sensor and dual pressure switches. It will turn on when the:
Discharge pressure drops below 40 psi (2.8 bar), or
Flow through the Inline 400 is ½ gpm (1.9 lpm) or greater
The Inline 400 system stops boosting pressure when the demand for water drops below the ½ gal-
lon-per-minute (1.9 lpm) flow rate (pump will turn off around 15 seconds after the flow stops). The
unit can also be manually shut down during normal operation by pressing the pushbutton on the cap.
The Inline 400 is easy to install (mounting either vertically or horizontally) while working with vir-
tually any existing plumbing configuration.
NOTE: Horizontal installations are approved for INDOOR use only. Vertical installations are
approved for OUTDOOR use when the clear protective cover is installed.

Features

Configuration
Plug-in electrical cord connected unit (60 Hz models only)
Installs vertically or horizontally
1 ¼" NPT (BSPT for 50 Hz model) Inlet and Outlet
Includes pressure tank if ordered as accessory
Maximum Inlet Water Temperature: 120 °F / 49 °C
Operation
Two LED indicators for system status and troubleshooting
Simple flow-based controls boost pressure on demand
Single phase operation
Maximum suction lift of 5 feet (1.5 m)
Protection
Overvoltage (+10% of rated)
Undervoltage (-10% of rated)
Dry Run (i.e. motor is running but no pressure or flow is being developed)
Overheat (greater than 120 °F internal water temperature)

Models

Input
Model
Voltage
Inline 400
115 VAC
Inline 400
230 VAC 60
220-230
Inline 400 50 Hz
VAC
Hz HP Current Power Phase
60
6.6 A
710 W
3.3 A
710 W
½
50
2.7 A
630 W
Maximum
Maximum
Boost
System
55 psi
95 psi
1
3.79 bar
6.55 bar
55 psi
95 psi
1
3.79 bar
6.55 bar
50 psi
90 psi
1
3.45 bar
6.21 bar
PRODUCT INFORMATION
Description
Maximum
Enclosure
Weight
Flow
Type
20 gpm
CSA
75 lpm
Type 3
20 gpm
CSA
35 lbs.
75 lpm
Type 3
16 kg
16 gpm
IP24
60 lpm
5