STOP – DO THESE STEPS FIRST
12:06 PM, Alarm 2 at 12:07 PM, Alarm 3 at 12:08 PM, and Alarm 4 at 12:09 PM. This allows a preset test
so you may become familiar with the alarm functions. When the clock reads 12:06 PM, the tray will rotate
and the first alarm will ring. To turn the alarm off, slide the white bar toward the center of the unit. To
close the unit, first check that the white bar beneath the display is in the position closest to the display,
marked by an "X". Place the top on the unit, first making sure the sliding door is closed. Rotate the top
counter-clockwise to secure it. The key should rotate counter clockwise and can then be removed. The unit
is now locked. Open the sliding door and the alarm will stop ringing. You should feel a small click when
the door slides all the way open. This click is the switch to turn off the buzzer. The open door will expose
the tray slot for the medication. Note the tray revolves clockwise. The unit will repeat this exercise for the
next three alarms. [If the alarm is not disabled by sliding the door up, take the lid off and slide the white bar
up with your finger. Shut the door before replacing the lid. The white bar was not in the proper position or
the door on the lid was not closed.]
4 – Remove the lid to set the time and the alarms. Set the time of day by first holding the TIME SET
button down and then depressing the HOUR, then the MIN, and then the AM-PM buttons as necessary. A
red light will indicate the PM. The alarms will be set in the same manner. Press the desired alarm button
for 2 seconds. The light will flash off and on as these settings are made. Set the hour, minute and AM-PM
buttons as desired for the first alarm. The light must be on for the alarm to be activated. Set Alarms 2, 3,
and 4 the same way, if needed. Turn off unused alarms by holding the alarm button down until the light
above the alarm button goes off. Now press the ALARM TEST button. This will show the direction of
rotation and show where the empty cup should be when the lid is replaced. Slide the white bar up to turn
the alarm off.
The MedReady unit has the ability to ring from 3 minutes up to 250 minutes
5 –
set time is 30 minutes. To set the length of time the alarm is to ring, press alarm test and hold. To lengthen
the ring time press the MIN button. The time will increase from 30, 45, 60, 250 and 3 minutes. The time
reaches 3 minutes and then returns to 30 minutes.
6 - Place one of the enclosed cardboard medication discs over the clock face and load the medication as
shown. To load one dose per day fills twenty-eight slots. To load twice daily place one then the other dose
leaving no empty cups. Load the medication in a counterclockwise direction. Verify the alarm light(s) are
1600, 1650 SETUP
dosage
features, see paragraph 7
1-The battery compartment lid is located on the
underside of the unit. Open the lid by sliding the tab
back and lifting after the tab clears the stop. Plug the
battery in. Notice the design of the plug allows it to
enter in only one direction.
2 - Plug the AC adapter into the unit and connect to
an electrical outlet. Unplug the AC adapter. Only the
colon will be visible in the display and it will be
flashing. This verifies the battery is operational in
case of a power outage. Plug the AC adapter back in
and replace the battery compartment lid.
3 - The factory setting of the clock is 12:00 P.M.
The factory settings of the alarms are: Alarm 1 at
away
early
with
and
. The factory