Download Print this page

Sealey POWER TOOLS SA52 Instructions page 2

Air flux chipper/needle scale

Advertisement

3.
PreParinG tooL for use
3.1.
air supply
3 .1 .1 . Ensure tool valve (or trigger) is in the "off" position before connecting to the air supply .
3 .1 .2 . You will require an air pressure of 90psi, and an air flow according to specification .
3 .1 .3 .  WarninG! Ensure the air supply is clean and does not exceed 90psi while operating the
tool . Too high an air pressure and unclean air will shorten the product life due to excessive
wear, and may be dangerous causing damage and/or personal injury .
3 .1 .4 . Drain the air tank daily . Water in the air line will damage the tool .
3 .1 .5 . Clean air inlet filter weekly . Recommended hook-up procedure is shown in fig .1 .
3 .1 .6 . Line pressure should be increased to compensate for unusually long air hoses (over 8
metres) . The minimum hose diameter should be 1/4" I .D . and fittings must have the same
inside dimensions .
3 .1 .7 . Keep hose away from heat, oil and sharp edges . Check hose for wear, and make certain
that all connections are secure .
3.2.
couplings.
Vibration may cause failure if a quick change coupling is connected directly to the tool . To
overcome this, connect a leader hose to the tool . A quick change coupling may then be used
to connect the leader hose to the air line recoil hose . See fig .1 & 2 .
fig.1
4. oPeratinG instructions
WarninG! ensure you read, understand and apply safety instructions before use.
note: Numbers in brackets refer to item numbers in the parts diagram .
4.1.
flux chipper
4 .1 .1 . Fit the spring (4) onto the rounded end of the chisel (15) before fitting the chisel into the
barrel sleeve (12) .
4 .1 .2 . Fit the nut (20) over the sharpened end of the chisel (15), screw it onto the barrel sleeve
(12) and tighten .
4 .1 .3 . Connect the tool to the air hose as in chapter 3 .
4 .1 .4 . To start the tool, depress the throttle lever .
4.2.
needle scaler
4 .2 .1 . To use as a needle scaler, unscrew the nut (20) and remove the chisel (15) and spring (4) .
4 .2 .2 . Fit the needle driver (14) and ensure the spring (18) is located in the needle tube (19) .
4 .2 .3 . Ensure the needle holder (17) is fitted with needles (16) such that the heads of the needles
do not protrude above the surface of the needle holder .
4 .2 .4 . Fit the needle holder (17) into the needle tube (19), screw the needle tube (19) onto the
barrel sleeve (12) and tighten .
4 .2 .5 . To start the tool, depress the throttle lever .
do not allow the tool to free run for an extended period of time as this will shorten its life .
5. Maintenance
Note: Numbers in brackets refer to item numbers in the parts diagram .
5.1.
5.2.
5.3.
5.4.
5.5.
5.6.
The SA52, when operated in accordance with these instructions and tested in accordance with EN 28662-1:
1993 results in the following vibration emission declared in accordance with BS EN12096: 1996 .
Measured vibration emission value: . . . . . . . . .6 .7m/s2 Uncertainty: . . . . . . . . . . . . . . 2 .68m/s2
these values are suitable for comparison with emission levels of other tools that have been subject to
the same test.
this tool may cause hand-arm vibration syndrome if its use is inadequately managed.
fig.2
recommended Measures to reduce risk of hand-arm vibration syndrome:
This tool should not be used by an individual regularly for more than
This duration of use should be reduced if the individual is exposed to hand-arm vibration from other sources .
declaration of conformity
air fLuX cHiPPer/needLe scaLer
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component
parts without prior notice. iMPortant: No liability is accepted for incorrect use of this equipment . Warranty: Guarantee is 12
months from purchase date . proof of which will be required for any claim . inforMation: For a copy of our latest catalogue and
promotions, call us on 01284 757525 and leave your full name and address including your postcode .
SA52
Issue No: 3 - 170909
WarninG! Disconnect tool from air supply before changing accessories, servicing or
performing maintenance . Replace or repair damaged parts . Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
To replace the needles (16), unscrew the needle tube (19) from the barrel sleeve (12) .
Remove the needle holder (17) and replace the needles (16) . (Use genuine Sealey needles
only .) Refit the needle holder (17) into the needle tube (19), screw it onto the barrel sleeve
(12) and tighten .
Lubricate the tool daily with a few drops of Sealey air tool oil dripped into the air inlet .
Clean the tool after use .
Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line . Moisture or restriction in the air pipe . Incorrect size
or type of hose connectors . To remedy check the air supply and follow instructions in
chapter 3 .
b) Grit or gum deposits in the tool may also reduce performance . Flush the tool out
with gum solvent oil or an equal mixture of SAE No 10 oil and paraffin .
Allow to dry before use .
For a full service contact your local Sealey service agent .
When not in use, disconnect from air supply, clean tool and store in a safe, dry,
childproof location .
risk of Hand arm Vibration injury.
We, the sole importer into the UK, declare that the product listed here is in conformity with the
following standards and directives . The construction file for this product is held by the Manufacturer
and may be inspected, by a national authority, upon request to Jack Sealey Ltd .
Model: sa52
2006/42/EC Machinery Directive
93/68/EEC Marking Directive
sole uK distributor
sealey Group,
Bury St . Edmunds, Suffolk .
136
minutes in any 8 hour period .
Signed by Mark Sweetman
11th September 2009
For Jack Sealey Ltd. Sole importer into the
UK of Sealey Power Tools.
01284 757500
www.sealey.co.uk
W e b
01284 703534
sales@sealey.co.uk
email
SA52
Issue No: 3 - 170909

Advertisement

loading