CHAPTER 3 FLASH UPDATE NOT POSSIBLE
signals which are necessary
If failuremessage from prommer
is "wrong manufactor/ device ID"
update prommerbox or change
D200
because of the missing possibility to rewrite phonedata after changing UEM D200 you should not change this part
-
D400
-
if it was necessary to change UPP D400 you have to make SW-update after reworking this part. Otherwise the phone will
not switch on!
D450
-
change Flash D450 in case that prommer box messages "wrong manufacor/ devive ID". Note that after changing D450 you
have to flash the phone, rewrite IMEI, Simlock data and Product code. Furthermore you have to run all RX/TX-tunings and
energy management calibration!
© NMP 2002
Flash update not possible
check that
for a working baseband
nOK
(voltages, sleepclock,
referenceclock, PURX)
are ok
OK
check that
FBUS_TXO-line rise
nOK
to 2.8VDC after start
flashing
OK
Flash D450
nOK
change UPP D400
CONFIDENTIAL
NHM-7
Date 28.02.2002
continue with section
"Phone does not switch on"
check pulse on
check components in
BSI-line (J101) after
nOK
start flashing
OK
check voltage at
check R102. Probably
nOK
J411 (1.8VDC)
OK
FBUS TX0
FBUS RX0
Checked by:
SCCE Training Group
Repairhints
Version 1.0 Approved
BSI-line
UEM D200 faulty
Approved by:
SCCE
8 (18)