Advertisement

Quick Links

I.D.E. e1.01 sunbed controller

Table of contents

Part I Installation
Part I is designed for the technician. It contains information about
electrical connections and I.D.E. e1.01 controller installation.
Part II Operating manual
Part II is designed for the user. It contains information about menu
configuration and operating cycle.
1. Operating mode ........................................................................... 4
2. Programming mode ...................................................................... 5
2.1. Default session time ............................................................ 5
2.2. Time delay........................................................................... 6
2.3. Advanced functions ............................................................. 6
2.3.1. Counters presentation ............................................... 7
2.3.2. Protected settings ..................................................... 7
2.3.2.1. Counters .......................................................... 8
Lamps counter 1 ..................................................... 9
Lamps counter 2 ..................................................... 9
Lamps counter 3 ................................................... 10
Fans counter ........................................................ 10
Time delays counter ..............................................11
Paid time counter .................................................. 11
Clients counter ..................................................... 12
2.3.2.2. Statistics ........................................................ 12
Electric energy counter ......................................... 12
Takings total counter ............................................ 13
2.3.2.3. Programming options ..................................... 14
Step ..................................................................... 14
Maximum time delay ............................................ 15
Maximum session time ......................................... 15
Ventilation ............................................................ 16
Price .................................................................... 16
Lamps end ........................................................... 17
Lamps power consumption .................................. 17
Fans power consumption ..................................... 18
Stop fans .............................................................. 18
Stop lamps ........................................................... 19
External stop ........................................................ 19
Buzzer ................................................................. 20
2.3.2.4. No code access .............................................. 20
2.3.2.5. Code change ................................................. 21
I.D.E. Systemy Elektroniczne
Symbols used in the manual
Version 1.1
07/2005
START
MENU
buttons inside sunbed
procceds automatically
T
with the time passage
ATTENTION!
EN
Page
1

Advertisement

Table of Contents
loading

Summary of Contents for IDE e1.01

  • Page 1: Table Of Contents

    Table of contents Part I Installation Part I is designed for the technician. It contains information about electrical connections and I.D.E. e1.01 controller installation. Part II Operating manual Part II is designed for the user. It contains information about menu configuration and operating cycle.
  • Page 2 I.D.E. e1.01 sunbed controller Part I Installation The installation of the I.D.E. e1.01 controller should be conducted by the authorized service. The producer does not take any responsibility for any damage or loss resulted from the installation conducted by the unauthorized service.
  • Page 3 START/STOP wire should not be connected (picture 4). Sunbed After the above connections have been made, fasten the I.D.E. e1.01 START/STOP button control panel and connect it to the power supply and operation device with the DB09 plug (picture 5).
  • Page 4: Operating Mode

    I.D.E. e1.01 sunbed controller Part II Operating manual 1. Operating mode To turn on sunbed: When the controller is on standby, press button. Default session START time (see page 5) will be displayed. Set the session time with buttons. START STOP 3.
  • Page 5: Programming Mode

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode Changes in the controller’s menu settings are executed in the programming mode. Controller’s main menu is protected by the code, which prevents from entering the unauthorized changes. There are two options in the main menu: Default session time (see page 5);...
  • Page 6: Time Delay

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode 4. To save new setting in the temporary memory, press START STOP buttons. To leave the programming mode and save new setting in the long term memory, press button or wait 60 seconds.
  • Page 7: Protected Settings

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode 2.3.1. Counters presentation The controller has 9 counters. In the Counters presentation submenu it is only possible to browse the contents of the following counters: Lamps counter 1 (see page 9);...
  • Page 8 I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode To access Protected setings submenu: 1. When the controller is in the programming mode (see page 5), in the Advanced functions submenu (see page 6), select Protected settings submenu with buttons.
  • Page 9 I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode Lamps counter 1 Lamps counter 1 (undeletable) shows real lamps operation time since the installation. Counter’s capacity: <0000h00m ; 9999h59m > Default setting: 0000h00m To browse lamps counter 1 contents: 1.
  • Page 10 I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode Lamps counter 3 Lamps counter 3 (deletable) shows real lamps operation time since the last deleting. Counter’s capacity: <0000h00m ; 9999h59m > Default setting: 0000h00m To browse and/or delete lamps counter 3 contents: 1.
  • Page 11: Paid Time Counter

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode Time delays counter Time delays counter (deletable) shows total time delays since the last deleting. Counter’s capacity: <0000h00m ; 9999h59m > Default setting: 0000h00m To browse and/or delete time delays counter contents: 1.
  • Page 12: Statistics

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode Clients counter Clients counter (deletable) shows the total operating cycles since the last deleting. Counter’s capacity: <0000 ; 9999 > Default setting: 0000 To browse and/or delete clients counter contents: 1.
  • Page 13: Takings Total Counter

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode To browse and/or delete electric energy counter contents: 1. When the controller is in the programming mode (see page 5), in the Statistics submenu (see page 12), select electric energy counter with buttons.
  • Page 14: Programming Options

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode 2.1.2. Programming options In the Programming options submenu (see page 14) it is possible to browse and change the following options: Step (see page 14); Maximum time delay (see page 15);...
  • Page 15 I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode Maximum time delay Maximum time delay is the maximum time delay value (Time delay, see page 6), that can be set in the operating mode (see page 4). Range of setting: 00 ;...
  • Page 16: Ventilation

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode Ventilation Option is used to set fans operating time after the session. Range of setting: < 00.00 ; 20.00 > (min) Default setting: 01.00 Step: 10 sec If the sunbed is equipped with the system of automatic ventilation, ventilation time, set in the controller’s menu,...
  • Page 17: Lamps End

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode Lamps end Option is used to set time, after which the lamps in the sunbed should be changed. Range of setting: off - option deactivated < 10 ; 2550 > (h)
  • Page 18: Fans Power Consumption

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode 3. Set new value with buttons. 4. To save new setting in the temporary memory, press START STOP buttons. To return to the Programming options submenu, press button. To...
  • Page 19: Stop Lamps

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode 2. To change the setting, press button. The stop fans symbol and START the stop fans new setting is displayed alternately. START To return to the Programming options submenu, press button.
  • Page 20: Buzzer

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode To return to the Programming options submenu, press button. To STOP leave the programming mode and save new setting in the long term memory, press button or wait 60 seconds.
  • Page 21: Code Change

    I.D.E. e1.01 sunbed controller Part II Operating manual 2. Programming mode To access No code access submenu: 1. When the controller is in the programming mode (see page 5), in the Protected settings submenu (see page 7), select No code access submenu with buttons.

Table of Contents