In the configuration on computer, the module address, frequency channel, network ID, and key are all in decimal
mode. The range of values of each parameter is:
Network address: 0-65535
Frequency channel: 0-83
Network ID: 0-255
Key: 0-65535
When the user configures the repeater mode using the host computer, special attention must be paid. Since the
parameters are in decimal mode in the host computer, the module address and network ID need to be converted into
hexadecimal. For example, if the network ID input by the transmitting end A is 02, and the network ID input by the
receiving end B is 10, when the repeater end R sets the module address, the hexadecimal value 0X020A is converted
into the decimal value 522 as the repeater end R. Module address. That is, the module address value of the repeater
terminal R is 522 at this time.