Thank you for purchasing an
AirScape® HEPA TOWER.
Your HEPA TOWER has been designed to quietly filter
the air in a room for many years to come.
The AirScape HEPA TOWER:
Pre-filter: High quality MERV 11 pre-filter
This HEPA Filter is rated at 99.95% efficiency
[European H13-Certified, test certificate included]
which offers 99.95% arrestance at 0.3 micron
particle size. HEPA standard uses 0.3 microns
as the "lowest point". This means that the
filtration efficiency increases for particle
diameters both less than and greater than
0.3 microns.
ECM Motor (High Efficiency) to quietly produce
high volume airflow in ten speed steps
(with optional remote control) capable of many
room air changes per hour.
Adjustable Louvered Air Exit, which allows you to
direct the filtered air in 4 directions to create the
optimum airflow pattern through the room. The
importance of a high to low airflow pattern can
not be overstated. Correct Air Flow will minimize
Low Flow Areas in the room.
Appearance; Outer Panels may be made in any
of the currently available materials
 Maple Veneer Panels (shown)
White Painted Aluminum (ACP)
Black Painted Aluminum (ACP)
HEPA TOWER Installation and Operation Manual, 0221
©AirScape, Inc., 2021. All Rights Reserved.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for AirScape HEPA TOWER

  • Page 1 Installation and Operation Manual Thank you for purchasing an AirScape® HEPA TOWER. Your HEPA TOWER has been designed to quietly filter the air in a room for many years to come. The AirScape HEPA TOWER: Pre-filter: High quality MERV 11 pre-filter ...
  • Page 2: Theory Of Operation

    If purchased , the wireless remote receiver is connected to the fan electrical box at the blue RMT RJ45 port. If purchased at the time of the purchase of the HEPA Tower, AirScape will install the remote receiver in the unit. If purchased after; Installation means removal of the rear panel, installation of the remote receiver and blue Cat5E cable, an operational test and reinstalling the rear panel.
  • Page 3 2-3 month lifespan Magnetic Inlet Grille Micro-Droplets Viruses Airborne Organisms Fungal Spores Pollen, Dust Filter Frame Screws in Filter Frame to hold HEPA Filter, Press-Fit Pre-Filter HEPA TOWER Installation and Operation Manual, 0221 ©AirScape, Inc., 2021. All Rights Reserved. Page 3...
  • Page 4: Start-Up And Operation

    4. The Air Exit Louvers have been adjusted for proper Air Direction (see operational tips) When running the HEPA Tower for the first time, make sure to observe it turning on, running at all of its speed settings, and turning off, also verify Timer works at 1 Hour Setting.
  • Page 5: Operating Tips

    Make sure the Pre-Filter and inlet Grille are installed correctly. Change the Pre-Filter every 2-3 months, change the HEPA Filter every 1-2 years.  Use your HEPA Tower’s fan higher speed settings to clean your room quickly, then switch to its lower settings to run it quietly and efficiently through the day. ...
  • Page 6 The HEPA Tower’s fan speed allows for audible and airflow adjustments. The higher the speed, the higher the airflow through the Tower. The image below shows the changes in airflow pattern with a higher velocity. Light blue arrow = 500 CFM. Dark blue arrow = 700 CFM.
  • Page 7 - walking back and forth will temporarily disturb the airflow pattern through the room and stir-up the layers close to the floor. HEPA TOWER AIRLAB TEST RESULTS These are the HEPA Tower results recorded with AirScape’s AirLab. The HEPA Tower was tested with new filters. Fan Setting Power (Watts)
  • Page 8: Maintenance

     Clean exterior paneling / wheels using mild soap and a clean cloth.  Visually inspect the unit, wheels, paneling, air-inlet grille and air-exit louver for proper functioning and fit. HEPA TOWER Installation and Operation Manual, 0221 ©AirScape, Inc., 2021. All Rights Reserved. Page 8...
  • Page 9 Mounts by screwing it into the Tower with a Philips head screwdriver. Tighten screws in a cross pattern. Inlet Grille magnetically mounts on the Tower HEPA TOWER Installation and Operation Manual, 0221 ©AirScape, Inc., 2021. All Rights Reserved. Page 9...
  • Page 10: Access Panel

    ACCESS PANEL HEPA Tower Rear Top (Access) Panel Removed Controller Fan’s Electrical Box Cord Wrap Box (removable) HEPA TOWER Installation and Operation Manual, 0221 ©AirScape, Inc., 2021. All Rights Reserved. Page 10...
  • Page 11: Troubleshooting

    Suggestion 4: Check for red LED responses on DTC when pressing the remote buttons. If problems are encountered, please take a few moments to run through the troubleshooting procedures described on the blue Warranty Card. If these suggestions do not work, contact AirScape technical support at 1.866.448.4187 or by email at experts@airscapefans.com...
  • Page 12 Motor Control Harness (24V PWM) FAN BOX 24VDC Resetable Circuit Breaker FAN BOX BOARD EL-9013 20 foot Power Cord 120VAC, 60Hz, 1 Phase, 15A Connect to dedicated circuit HEPA TOWER Installation and Operation Manual, 0221 ©AirScape, Inc., 2021. All Rights Reserved. Page 12...

Table of Contents