Important assembling advice .......... 14 Installation notes ............15 CAUTION! The S-line is a wall mounted drain. When using a membrane clamp to seal the bottom layer of the shower, you should make sure that the diameter of the clamp is not too large for a wall mounted installation of the drain.
LEAST ½ ” ABOVE THE WOODEN FLOOR PAN LINER WITH ADHESIVE BONDING SEAL THE ENTIRE FLOOR WITH PAN LINER REMOVE AIR POCKETS BENEATH THE LINER CONCRETE BOARD (AT LEAST ¼” ABOVE THE FLOOR) *NOTE: Clamp drain may vary depending on model being used S-line...
SEAL THE ENTIRE FLOOR WITH PAN LINER REMOVE AIR POCKETS BENEATH THE LINER CONCRETE BOARD (AT LEAST ¼” ABOVE THE FLOOR) NO-HUB SLEEVE* NOT INCLUDED OPTION: CURBLESS SHOWER INSTALLATION >> CONTINUE ON PAGE 8 *NOTE: No-hub sleeve may vary depending on model being used S-line...
INSTALLATION DIAGRAM - WALL | STANDARD CLAMP DRAIN PLYWOOD CONCRETE S-line drain body Sloped mortar bed - first layer TAF (Tile Adjustable Frame) Sloped mortar bed - second layer TAF Grating Pan liner / Moisture resistant material Strainer Pea Gravel Elastic sealant - Silicone 2”...
Suitable for renovation work and new construction The Easy Drain S-line should only be installed by trained professionals in compliance with state and local building codes. To achieve the best possible result, please carefully read the installation guide. If you have any questions, please consult your supplier.
Need help?
Do you have a question about the S-line and is the answer not in the manual?
Questions and answers