Additional Safety Information - Craftsman CMECSP610 Instruction Manual

Chainsaw / pole saw
Hide thumbs Also See for CMECSP610:
Table of Contents

Advertisement

Available languages

Available languages

English
Storage
1 . Store indoors. The best storage place is one that is cool
and dry away from direct sunlight, excess heat or cold and
out of the reach of children.
2 . Always reduce the tension off the chain again after
finishing work. The chain contracts as it cools down.
If tension is not reduced, it can damage the saw.

Additional Safety Information


WARNING: Never modify the power tool or any part
of it. Damage or personal injury could result.

WARNING: ALWAYS use safety glasses. Everyday
eyeglasses are NOT safety glasses. Also use face or
dust mask if operation is dusty. ALL USERS AND
BYSTANDERS MUST ALWAYS WEAR CERTIFIED
SAFETY EQUIPMENT:
ANSI Z87.1 eye protection (CAN/CSA Z94.3),
ANSI S12.6 (S3.19) hearing protection,
NIOSH/OSHA/MSHA respiratory protection.

WARNING: Some dust created by power sanding,
sawing, grinding, drilling, and other construction
activities contains chemicals known to the State
of California to cause cancer, birth defects or
other reproductive harm. Some examples of these
chemicals are:
lead from lead-based paints,
crystalline silica from bricks and cement and
other masonry products, and
arsenic and chromium from chemically-
treated lumber.
Your risk from these exposures varies, depending on
how often you do this type of work. To reduce your
exposure to these chemicals: work in a well ventilated
area, and work with approved safety equipment, such
as those dust masks that are specially designed to
filter out microscopic particles.
Avoid prolonged contact with dust from power
sanding, sawing, grinding, drilling, and other
construction activities. Wear protective clothing and
wash exposed areas with soap and water. Allowing
dust to get into your mouth, eyes, or lay on the skin may
promote absorption of harmful chemicals.

WARNING: Use of this tool can generate and/
or disperse dust, which may cause serious and
permanent respiratory or other injury. Always use
NIOSH/OSHA approved respiratory protection
appropriate for the dust exposure. Direct particles
away from face and body.

WARNING: Always wear proper personal
hearing protection that conforms to ANSI
S12.6 (S3.19) during use. Under some conditions
and duration of use, noise from this product may
contribute to hearing loss.

CAUTION: When not in use, place tool on its
side on a stable surface where it will not cause
8
a tripping or falling hazard. Some tools will stand
upright but may be easily knocked over.
Air vents often cover moving parts and should
be avoided. Loose clothes, jewelry or long hair can be
caught in moving parts.
An extension cord must have adequate wire size
(AWG or American Wire Gauge) for safety. The
smaller the gauge number of the wire, the greater the
capacity of the cable, that is, 16 gauge has more capacity
than 18 gauge. An undersized cord will cause a drop in
line voltage resulting in loss of power and overheating.
When using more than one extension to make up the
total length, be sure each individual extension contains
at least the minimum wire size. The following table shows
the correct size to use depending on cord length and
nameplate ampere rating. If in doubt, use the next heavier
gauge. The lower the gauge number, the heavier the cord.
Minimum gauge for Cord sets
Total length of Cord in Feet
Volts
120V
25 (7.6)
240V
50 (15.2) 100 (30.5) 200 (61.0) 300 (91.4)
Ampere Rating
More
not
Than
More
Than
0
6
18
6
10
18
10
12
16
12
16
14
The label on your tool may include the following symbols. The
symbols and their definitions are as follows:
V ......................... volts
Hz ....................... hertz
min ..................... minutes
or DC ...... direct current
...................... Class I Construction
(grounded)
.../min .............. per minute
BPM .................... beats per minute
IPM ..................... impacts per minute
RPM .................... revolutions per
minute
sfpm ................... surface feet per
minute
SPM .................... strokes per minute
OPM .................... oscillations per
minute
A ......................... amperes
W ........................ watts
or AC ........... alternating current
(meters)
50 (15.2) 100 (30.5) 150 (45.7)
American Wire gauge
16
16
16
14
16
14
12
Not Recommended
or AC/DC .... alternating or
direct current
...................... Class II
Construction
(double insulated)
n o ....................... no load speed
n ......................... rated speed
...................... earthing terminal
..................... safety alert symbol
..................... visible radiation
..................... avoid staring at
light
..................... wear respiratory
protection
..................... wear eye
protection
..................... wear hearing
protection
..................... read all
documentation
IPXX .................... IP symbol
14
12
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents