Monitoring control system
Hide thumbs Also See for SIMPLIFY:

Advertisement

Quick Links

USER MANUAL
SIMPLIFY MONITORING CONTROL SYSTEM
en
Rev. 1.0 • 2021-W21-4

Advertisement

Table of Contents
loading

Summary of Contents for Dantherm SIMPLIFY

  • Page 1 USER MANUAL SIMPLIFY MONITORING CONTROL SYSTEM Rev. 1.0 • 2021-W21-4...
  • Page 2 Dantherm can accept no responsibility for possible errors and changes (en) Der tages forbehold for trykfejl og ændringer (da) Irrtümer und Änderungen vorbehalten (de) Dantherm n’assume aucune responsabilité pour erreurs et modifications éventuelles (fr)
  • Page 3: Table Of Contents

    Simplify Dashboard users and assigned Simplify Control Units . . . . . . . . . . . . . . . .
  • Page 4: Overview

    The protection class for the devices is defined in the section on “IP class, description” on page 27 . The Manual or parts thereof may not be copied without Dantherm’s prior written consent . Copyright Dantherm reserves the right to make changes and improvements to the product and the manual Reservations at any time and without prior notice or obligations .
  • Page 5 Introduction: Overview System parts and This Manual uses the following terminologies and abbreviations in connection with the Simplify description Monitoring Control System . Abbrevia- tions Simplify Control Unit The Control Unit is placed centrally so that all Sensor Boxes, Integration Boxes and Relay Boxes have the best possible radio contact .
  • Page 6 Introduction: Overview Recycling The devices and the system are designed for a long service life . Once the product reaches its end of life, recycle all physical devices in accordance with the na- tional regulations and with due consideration for the environment . The electrical and electronic equipment and accompanying batteries contain materials, compo- nents and substances that can be hazardous to human health and the environment if the waste is not managed properly .
  • Page 7: Declaration Of Conformity

    Tel.: +45 96 14 37 00 Fax: +45 96 14 38 00 Declaration of following product: Product name: Simplify control unit, Simplify sensor box, Simplify on/off relay, Simplify integration sensor Product no.: 380000, 380003, 380005, 380006 The product is in conformity with the following directives:...
  • Page 8: Product Description

    Simplify works both as a stand-alone system and in combination with Dantherm CDT Dehu- midifiers from the MKII series and later . • A number of Sensor Boxes can be connected to Simplify . However, for best ease of use, we recommend the use of not more than 50 Sensor Boxes . •...
  • Page 9: Transportation, Handling And Storage

    If any form of transport damage is discovered after unpacking devices, or if the ship- ment is defective, contact your local dealer as quickly as possible . Contents Overview of units to the Simplify system: Illustration Simplify - case Simplify Control Unit...
  • Page 10 Simplify Relay Box, 3 outputs (Relay Boxes are available in different ver- sions, for voltages other than 184-265 VAC as well as for other types of sockets) . Sensor for incorporation into CDT MII/III (option) Illustration Simplify integration Sensor Box for CDT MKII/III .
  • Page 11: Use

    How to use: Introduction How to use Introduction The Simplify Installation App is available for both Android (version 5 .1 or later) and iOS (iOS10 or later) . Android App: Download the Installation App via Google Play: Dantherm via App Store: Dantherm The App looks different in App Store and in Google Play .
  • Page 12 How to use: Introduction APP Layout Name the Control Unit . Mark the “pencil” (iOS: mark the line NAME) and specify the address, case number, etc . (This will be indicated on the Dashboard as the case ID) . Maximum 30 characters (UTF-8, which are the common keys found on the keyboard) .
  • Page 13: Installation

    Installation: System setup Installation System setup System setup Setup Connect a Control Unit to 230 V mains voltage . The Control Unit will flash orange . Once the Control Unit has established GSM connection, the light will be solid ORANGE (this takes approx .120 seconds) . If there is no 230 V supply and backup power is activated, the Control Unit will be solid RED .
  • Page 14: Extending/Replacing A Sensor Box In An Active Installation

    Installation: Extending/replacing a Sensor Box in an active installation Extending/replacing a Sensor Box in an active installation An installation can be extended without powering down the Control Unit . When a new Sensor Box is connected, scan the Control Unit QR code, press “REGISTER” in the App, and then the Control Unit will upload every minute for the next hour .
  • Page 15: Use

    Use: Use of CDT Dehumidifiers with Integration Box Use of CDT Dehumidifiers with Integration Box When repairing water damage, it can be advisable to use one or more CDT Dehumidifiers and NOTE! receive data from them . This is done via the relevant CDT Dehumidifiers being scanned on a Control Unit . Data from all CDT Dehumidifiers will then be displayed on the Dashboard .
  • Page 16: Simplify Dashboard

    Simplify Dashboard: Introduction Simplify Dashboard Introduction Fig . 1 Receiving data Data will be visible in the Dashboard when the Control Unit has uploaded data that is received from Sensor Boxes . • The first data is received after a couple of minutes . All Sensor Boxes transmit 10 data points in the first 10 minutes, subsequent transmissions are performed at the interval selected in the Dashboard .
  • Page 17 Simplify Dashboard: Introduction Dashboard • All Control Units associated with the user are displayed . installation view • If a Control Unit appears as “ACTIVE”, the user can see when it was last online in the field “Last seen online” .
  • Page 18 Simplify Dashboard: Introduction CHART view • To switch to “Chart View”, click on a Control Unit and press “NEXT” or double-click the Control Unit . “HUM” (relative humidity) is then displayed by default for all Sensor Boxes linked to the Control Unit .
  • Page 19 Simplify Dashboard: Introduction • If an integration sensor or Relay Box is installed, each of these will be displayed by default under the graph with total kWh consumption per Integration Sensor and Relay Box . Total combined power consumption in kWh is displayed .
  • Page 20 Simplify Dashboard: Introduction ALARM from When an alarm is received from the Integration Box, it looks as on “Fig . 2” on page 20 . Integration Box Fig . 2 DASHBOARD ON/ Equipment connected to a Relay Box or Integration Box can be turned on and off directly from the Dashboard .
  • Page 21 Simplify Dashboard: Introduction from previous case as well as the new case will be visible in the Dashboard . The Control Unit will not start an upload every minute, which is the default for Control Units that come from archived state .
  • Page 22: Simplify Dashboard Users And Assigned Simplify Control Units

    Simplify Dashboard users and assigned Simplify Control Units Administrator Dantherm Intelligent Monitoring A/S can offer to devise and maintain a user hierarchy . access The Company User and Supervisor User roles can create, edit and delete a user hierarchy with 3 levels: via the top menu “Admin”:...
  • Page 23: Troubleshooting

    Troubleshooting: Simple self-help Troubleshooting Simple self-help Use this table to localise and rectify a problem or an error: The Control Unit Poor or no GSM cover- Move the Control Unit to obtain better GSM cover- does not become age . orange (does not If the connection still does not work, replace the connect to the...
  • Page 24 Troubleshooting: Simple self-help The App does not The App needs to be Never use old versions of the App . work . updated . Check where updates are available in Google Play or App Store . The mobile/tablet runs Update to an Android version earlier than 5 .1 and an Android version iOS 10 or earlier .
  • Page 25: For Additional Information

    Find and download the latest version of the Service Manual and Quick Guide here: https://support .dantherm .com/ or contact Dantherm Intelligent Monitoring A/S Kirkebjerg Parkvej 12 Brøndby DK 2605 Denmark Tel .: +45 70 22 11 20 E-mail: info@dantherm .com Dantherm Intelligent Monitoring A/S . If you need spare parts, contact...
  • Page 26: Appendix

    Warning Protect the Relay Boxes with maximum 16-ampere fuse . CAUTION National versions of the Relay Box are available . Caution NOTE! Contact Dantherm Intelligent Monitoring A/S for additional information . Data, Sensor Probe Data Unit Specification Voltage 3 .3 Current 1 .5...
  • Page 27 Appendix: Technical data Data, Integration Data Unit Specification Mains voltage 9-18 Current in Tx/Rx state 12/5 Tx power max . Tx/Rx frequency Temperature range, storage °C -40 to +60 Temperature range, operation °C -20 to +60 Protection class IP class, IP 54: description Protected against dust .
  • Page 28: Dimensions

    Appendix: Dimensions Dimensions Control Unit 173,9 184,5 Sensor Box Rotary aerial Relay Box...
  • Page 29 Appendix: Dimensions Sensor Probe Integration Box...
  • Page 32 Manufacturers details: Dantherm Intelligent Monitoring A/S Kirkebjerg Parkvej 12 Brøndby DK 2605 Denmark t. +45 70 22 11 20 e. info@dantherm.com KEEP UPDATED FOLLOW US ON: danthermgroup.com...