WARNING DO NOT USE START/STOP, INHIBIT OR ENABLE FUNCTIONS AS A
SAFETY DISCONNECT. USE ONLY AN AC LINE DISCONNECT FOR THAT PURPOSE.
4.7.4
Inhibit – The control can be electronically
stopped and started with the Inhibit circuit. To
"Stop"
must be connected as shown. The control can
be
restarted
See Figure 10A.
Note: The Inhibit Circuit is not isolated. Do not
4.7.5
Enable – The control can also be started and
stopped with an Enable circuit (the Enable circuit functions opposite to that of the
inhibit circuit; inhibit: open to start, close to stop, Enable: open to stop, close to start).
The Enable function is established
potentiometer lead connected to terminal P3. The Enable circuit is not isolated. Do not
common or ground wiring. See Figure 10B.
VLT
MAIN POTENTIOMETER
Note: The MIN speed trimpot must not be set higher than 70% CW rotation
(Approx. 2:00 o'clock position) or Enable will not function.
4.8 Signal Isolator Connection
In the event that an isolated signal voltage is not available, an optional signal isolator may be
installed. Reference Instruction Manual, MN1373. Signal Isolator Board.
21
the
control,
Terminals
by
opening
common or ground inhibit leads.
FIGURE 10B – ENABLE CIRCUIT WIRING
SWITCH,RELAY OR FET
OPEN TO "STOP"
CLOSED TO "START"
I1
&
I2
the
contact.
by wiring a contact in series with the violet
VLT
P3
MAIN POTENTIOMETER
FIGURE 10A – INHIBIT CIRCUIT
WIRING
SWITCH OR RELAY
OPEN TO"START"
CLOSE TO "STOP"
I1
I2
P3
A SOLID STATE RELAY CAN
ALSO BE USED WITH AN
OPEN COLLECTOR