Do you have a question about the Freepour and is the answer not in the manual?
Questions and answers
Summary of Contents for SSM Freepour
Page 1
D00142 A05 User Manual and Installation Guide This guide applies to Freepour 1.0 dispenser range Item codes: JUG2.0-CM-13, JUG2.0-CM-23, JUG2.0-CM-14, JUG2.0-CM-14 www.sixsimplemachines.com.au...
It is simple to use, clean and maintain. In order to ensure the system remains hygienic and in top working order it is important that you read and understand this manual before connecting your Freepour station to a power outlet.
Page 3
Step E - Connect fluid product lines inside Chiller Airflow Step F - Connect Data cables Lifting Step G - Fix Dispenser in place environment Step H - Commissioning Freepour ALLergen AdViCe Step I - Assess Chiller drain plug Before first service 1. ProduCt oVerView optional procedures...
Page 4
Chiller. Do not cover the Chiller grilles or Stand-by mode block entry or exhaust airflows by placing objects Milk lines in Freepour must be sanitised with Daily up against the Chiller. Temperature setpoint Milk Line Cleaner. Juice lines must be sanitised with Daily Juice Line Cleaner.
FunCtions Freepour self-serve beverage dispenser is a chilled We have designed Freepour to be easy and beverage dispensing system designed to satisfy a intuitive to use. Below is a basic overview of the variety of food service applications.
Page 6
PLAnning the disPense stAtion FreePour disPenser And ControL unit The modular design of Freepour allows for a variety of installation configurations to suit your dispense station Positioning the disPenser layout. When deciding where each of the three units will be located, consider how the machine will be used in service, reloaded by staff and cleaned at the end of the day.
If you install the Freepour Automatic Start-Up Chiller on a plinth we Connect the cabinet to the mains power supply The cabinet must be positioned on a level surface...
Route the drain hose to a drain and cut hose not sagging sagging to length. To account for all Freepour variants, fluid product lines are supplied long and need to be cut before IMPORTANT: For good drainage ensure adequate connecting to the manifold inside the Chiller.
Page 9
(as a % between 0 and 100) for Tap B; somewhere in the system. You may need to top up Use key to navigate back to the FREEPOUR Use key to navigate back to the FREEPOUR the cleaning bottle a few times during this test.
Page 10
ProCedure top position; Use the ON-MANUAL BACKUP switch to select To work well in Freepour, bladders must: Remove red caps from the black connectors NOTE: Push the tray in quickly so milk does not between the following 2 operating modes: inside the Chiller;...
Page 11
CLeAning routine Unit: ACTIVATE >; ON-MANUAL BACKUP switch must be in the ON Freepour can be run on as few as one bag of each The milk and juice systems are independently NOTE: The cleaning routine runs unassisted for position (pressed in).
Freepour Chiller 4. Freepour Chiller Carel Easy - Icons and Functions FreePour ChiLLer stAnd-by Mode Changing settings that relate to the operation of Press and hold the stand-by button for three Item Icon Function the Chiller is performed through the electronic seconds to turn stand-by mode on or off.
Call a service technician. Listen for the sound of the pumps running and/see • The Freepour power supply may have failed. that the tap(s) are dispensing. Dispensing cannot be activated on one or both taps Check Control Unit screen to see if there is the NO If the NO CURRENT error is displayed on screen: Reconnect pump cable and press ...
Page 15
Troubleshooting Troubleshooting Problem troubleshooting tips Possible Cause solution Audible 'gurgling' sound and no product is Check to see that red caps are being used correctly The red caps may be upside down or not properly Follow instructions on pages 18 and 19. dispensed or product being dispensed is unusually (see: BLANKING page 18 and ACTIVATING THE pushed onto the black connector(s) inside the...
Need help?
Do you have a question about the Freepour and is the answer not in the manual?