Cabling
The M-12 supplied with Neutrik Speakon
through, and 1+/1- LF, 2+/2- HF when in biamp mode. It is recommended that the resistance of your cable is less
than one tenth of the nominal system impedance. Given below are the recommended maximum cable lengths for
different cross-sections and impedances.
Conductor Cross Sectional Area
2
1.0mm
2
1.5mm
2
2.0mm
2
2.5mm
2
4.0mm
2
6.0mm
TM
NL4 connectors, wired pin 1+/1- in passive mode with 2+/2- as link-
Maximum Recommended Cable Length
4 ohms
11m
17m
22m
29m
44m
66m
6
M-12 User Manual
www.emacoustics.co.uk
8 ohms
16 ohms
22m
34m
44m
58m
88m
132m
44m
68m
88m
116m
176m
264m