Download Print this page

Sealey Power TOOLS PREMIER SA95.V3 Instructions page 2

Air adhesive stripe removing tool

Advertisement

2.2.
Specification
Free Speed . . . . . . . . . . . . . . . . . . . 2500rpm
Operating Pressure . . . . . . . . . . . . . . . .90psi
Air Consumption. . . . . . . . . . . . . . . . . . . 4cfm
Air Inlet . . . . . . . . . . . . . . . . . . . . . . . 1/4"BSP
3.
PREPARATION FOR USE
3.1.
Air Supply
WARNING! Ensure the air supply is clean and does not exceed 90psi while operating the tool. Too high
p
an air pressure and unclean air will shorten the product life due to excessive wear and may be
dangerous, causing damage and/or personal injury.
3.1.1. Ensure the air valve (or trigger) is in the "off" position before connecting to the air supply.
3.1.2. You will require an air pressure of 90psi, and an air flow according to specification.
3.1.3. Drain the air tank daily. Water in the air line will damage the tool and will invalidate your warranty.
3.1.4. Clean air inlet filter weekly. Recommended hook-up procedure is shown in fig.2.
3.1.5. Line pressure should be increased to compensate for unusually long air hoses (over 8metres).
The minimum hose diameter should be 1/4" internal diameter and fittings must have compatible
dimensions.
3.1.6. Keep hose away from heat, oil and sharp edges. Check hoses for wear, and make certain that all
connections are secure.
3.2.
Couplings
Vibration may cause failure if a quick change coupling is connected directly to the tool. To overcome
this, connect a leader hose to the tool (Sealey ref: AH2R or AH2R/38). A quick change coupling may
then be used to connect the leader hose to the air line recoil hose. See fig.1 & fig.2.
fig.1
4. OPERATING INSTRUCTIONS
WARNING! Ensure you read, understand and apply Section 1 safety instructions.
p
4.1.
Assembly
4.1.1. Screw composite pad fully onto shaft of removing tool. Use only pads with speed ratings equal to or
higher than the speed rating of the tool. A spanner is provided to hold the shaft during pad removal.
4.1.2. Connect air supply to tool and press control valve lever (push safety catch forward) to check for correct
operation.
4.1.3. The air flow may be regulated by the control valve lever.
fig.2
Original Language Version
Noise . . . . . . . . . . . . . . . . . . . . . . . . . .87dBA
Vibration . . . . . . . . . . . . . . . . . . . . . . . 1.9m/s
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . 1kg
Spare Pad Part No. . . . . . . . . . . . . .SA95/PX
2
SA95.V3 Issue: 1 - 22/09/11

Advertisement

loading

This manual is also suitable for:

Power tools premier sa95