Kv Kv; And; Renewal Parts; Breaker - Westinghouse DH-P Series Instructions Manual

Table of Contents

Advertisement

5 4
RENEWAL PARTS
Parts Most Subject
to
Wear in
Normal
Operation
.
Pole
Unit
Parts
-
4.16
Kv and
13.8
Kv
1200
and
2000 amp
.
All parts not marked for
a
particular rating
are common to
all ratings
.
Required Number
for
one
Pole Unit
.
1 #
1
.
Stationary arcing
contact
assembly
,
Fig
.
15
,
item 15
.
2
.
Movable arcing
contact
,
Fig
.
15
,
item 21
.
3
.
Stationary main
contacts
,
1200
amp
.
,
Fig
.
15
,
item 3
.
4
.
Stationary main
contacts ,
2000 amp
.
,
Fig
.
15
,
item 41
.
5
.
Movable
main
contact , 4.16
KV
, 1200 amp
.
,
R
.
H
.
,
Fig
.
15
,
item 26
.
6
.
Movable main
contact
,
4.16 KV
,
1200 amp
. ,
L
.
H
.
,
Fig
.
15
,
item 25
.
7
.
Movable
main
contact
,
4.16
KV
,
2000 amp
.
,
R
.
H
.
,
Fig
.
15
, item
40
.
8
.
Movable
main
contact ,
4.16 KV
,
2000 amp
.
,
L
.
H
.
,
Fig
.
15
,
item 39
.
9
.
Movable main
contact ,
13.8 KV
,
1200 amp
.
,
R
.
H
.
,
Fig
.
16
,
item 8
,
10
.
Movable main
contact ,
13.8 KV
,
1200 amp
.
,
L
.
H
.
,
Fig
.
16
,
item 7
.
11
.
Movable main
contact ,
13.8
KV
,
2000 amp
.
, R
.
H
.
,
Fig
.
16
,
item 10
.
12
.
Movable main
contact ,
13.8 KV
,
2000
amp
.
,
L
.
H
.
,
Fig
.
16
,
item 9
.
13
.
Movable
contact
pad
,
Fig
.
15
,
item 20
.
14
.
Movable
contact
hinge pin , 1200 amp
.
,
Fig
.
15
,
item 31
.
15
.
Movable
contact
hinge pin
,
2000
amp
.
,
Fig
.
15
,
item
42
.
16
.
Movable
contact
hinge spring washers
,
Fig
.
15
,
item 37
.
17
.
Movable
contact
lift rod ,
Fig
.
15
,
item 6
.
18
.
Puffer tube
assembly
4.16 KV
,
Fig
.
15
,
item 9
.
19
.
Puffer
tube assembly
13.8
KV
,
Fig
.
16
,
item
3
.
20
.
Kick
out
spring
,
Fig
.
15
,
item 29
.
21
.
Disconnecting
contact
finger cluster
,
1200 amp
.
,
Fig
.
14
,
indicated
.
22
.
Disconnecting
contact
finger cluster
,
2000 amp
.
,
Fig
.
15
,
item 43
.
23
.
Complete
pole
unit less lift rod
and disconnecting finger
contact
clusters
,
1200 amp
.
, 4.16
KV
,
Fig
.
15
.
24
.
Complete pole
unit
as
specified in
item 23
except
,
2000 amp
.
, 4.16
KV
.
,
Fig
.
15
.
25
.
Complete pole unit
as
specified in item 23
except ,
1200 amp
.
,
13.8 KV
,
Fig
.
16
.
26
.
Complete pole
unit
as
specified in item 23
except ,
2000
amp
.
,
13.8
KV
,
Fig
.
16
.
1 #
1
set
#
1
set
#
1
1
1
1
1
1
1
1
1 #
1
1
1
1
1
1
1
2
2
1
1
1
1
Note :
For one to five circuit breakers
,
order
parts identified
#
.
For
six
to ten
circuit
breakers
,
order
double quantity
identified #
,
plus
required number of all other
parts recommended
.

Advertisement

Table of Contents
loading

Table of Contents