  • Page 1 Clean Water Booster Sets POWERBOOST Flow Range O&M Manual...
  • Page 2: Table Of Contents

    POWER BOOST by EPS Group Table of Contents General Installation Checklist Location Consideration Installation Information & Diagrams Commissioning Pressure Vessel Pump Specifi cation Controller Specifi c Instructions & Troubleshooting Declaration of Conformity...
  • Page 3: General

    POWER BOOST by EPS Group General Delivery and Handling The weight and size of the POWERBOOST unit may require the aid of lifting equipment and must be handled in a safe manner. The unit must be lifted only by the base and not the pipe work, pumps or vessel.
  • Page 4: Installation Checklist

    POWER BOOST by EPS Group Installation Checklist Check the unit for any visual defects. Contact your supplier immediately if any are found. Choose a suitable location for installation. Please ensure the unit is fitted in accordance with these instructions. Connect the inlet and outlet pipe work as per the installation diagram.
  • Page 5: Location Consideration

    Installation Information & Diagrams NOTES IF IN DOUBT ASK DO NOT SCALE OFF THIS DRAWING ALL ITEMS TO BE TAGGED WITH EPS TAG STATING; EPS, DRAWING No, PURCHASE ORDER No. FOR HANDRAIL DETAILS SEE EPS DRAWING; EPS/A-L/HANDRAILING/RAILFAB. 1st ANGLE...
  • Page 6: Commissioning

    POWER BOOST by EPS Group Electrical Installation The POWERBOOST unit is designed for professional installation and should be connected by a suitably qualifi ed electrician in accordance with the latest IEE regulations. Ensure that the electrical supply is fully isolated before removing any electrical covers. The POWERBOOST unit must be earthed and it is recommended that an RCD is fi tted on the incoming electrical supply.
  • Page 7: Pressure Vessel

    POWER BOOST by EPS Group Turn on the power supply to the controllers and press the start button on the controllers. Slowly open the discharge valve on the booster unit to gradually fi ll the delivery main. Once water is fl owing from the nearest outlet, check the pipe work around the set for leaks.
  • Page 8: Pump Specification

    POWER BOOST by EPS Group Pump Specification Flow V Variable Speed Power Amps Per Pump Factory Maximum Pump System 230V 400V Cut In Flow Pressure Pressure 4CR80 0.55 0.75 5CR80 0.75 4CR100 0.75 5CR100 4CR200 5CR200 6CR200 10.2...
  • Page 9: Controller Specifi C Instructions & Troubleshooting

    POWER BOOST by EPS Group Controller Specifi c Instructions & Troubleshooting Starting up: Steadypres By pressing START STOP you Switch on power to controller put the inverter IN SERVICE and wait the STARTING time or OUT OF SERVICE. (approx. 10 sec.) Set pressure quick adjustment: Steadypres P 3.3...
  • Page 10 POWER BOOST by EPS Group Controller Specific Instructions & Troubleshooting Alarms: Steadypres OVER The current exceeded the allowable tolerance on the current set. The inverter CURRENT % stops the pump, the rearm is only manual. CURRENT Occurs if, in the absence of flow, the pump cannot reach the SET pressure, but can...
  • Page 11: Declaration Of Conformity

    POWER BOOST by EPS Group DECLARATION OF CONFORMITY PLEASE KEEP THIS DOCUMENT IN A SAFE PLACE EPS Group Mallow Business and Technology Park Quartertown Mallow Co Cork P51 AC94 Telephone: +353 (22) 31200 Email: info@epswater.ie Hereby declare that: Equipment: POWERBOOST PRO E, PRO S, & FLOW V Ranges...
  • Page 12 IRL & NI powerboost.ie info@powerboost.ie 094 963 3500 (IRL) 028 9181 8347 (NI) power-boost.co.uk info@power-boost.co.uk 01543 415200 POWERBOOST by EPS Group...