Download Print this page

Akw Level Best Installation And User Care Instructions

Deflector screen

Advertisement

Quick Links

Level Best
Guaranteed
for
Life
*
15
EN14428
Suitable for
shower trays
and wet floors
Level Best
Deflector Screen
installation and user care instructions
Installer- please read all instructions carefully before installation and leave
these instructions with the end user for future reference as this document
contains important warranty information.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Level Best and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Akw Level Best

  • Page 1 Level Best Guaranteed Life EN14428 Suitable for shower trays and wet floors Level Best Deflector Screen installation and user care instructions Installer- please read all instructions carefully before installation and leave these instructions with the end user for future reference as this document...
  • Page 2 When you unpack the product: Take care when you unpack the product and make sure that you do not inadvertently discard any small parts. If any parts are missing or damaged contact the AKW customer services. Before you start work: Check the shower tray or wet-floor is level and is completely sealed to finished or tiled walls.
  • Page 3: Table Of Contents

    Post block footplate installation Installation Pages Steps 3 Installing the fixed panel Step 4 Installing the deflector screen 10-11 Step 5 Installing the wall tie bar 12-13 Final Installation Pages Securing & fixing Sealing the enclosure & aftercare © 2016 AKW 15-010-048-01...
  • Page 4: Preparation

    Install the enclosure on the inside edge of the flat portion of the tray. Avoid installing over the edge radius as this will cause leakage. © 2016 AKW 15-010-048-01...
  • Page 5: Wall Profile Installation

    Ensure the fixing holes are to the inside of the enclosure. 4x35mm Do not silicone between the wall profile and the wall as further adjustment may be required. Only seal the entire enclosure after installation. See page 15 © 2016 AKW 15-010-048-01...
  • Page 6 IMPORTANT: The post block must be installed before the deflector screen is assembled. Install the post block footplate onto the tray or floor before installing the fixed panel or deflector screen. Continue to mark out the footplate. Wall Profile Panel © 2016 AKW 15-010-048-01...
  • Page 7: Post Block Footplate Installation

    35 m m Post block footplate Fitting of the post 35 m m block footplate will be approx 35mm from the front edge of the bottom hinge. Mark the centre of the footplate © 2016 AKW 15-010-048-01...
  • Page 8 01905 560219 www.akw-ltd.co.uk Install bottom post block foot-plate Remove the screen to install the footplate. Drill both footplate and bottom hinge holes and secure the footplate into position. Realign and secure the deflector screen into position. Footplate © 2016 AKW 15-010-048-01...
  • Page 9: Installation

    Do not drill the secondary Align the panel and screw and drill through adjusting holes just yet, these are for through adjusting slot slot hole at its longest final securing. holes to temporarily hold position. door in place. © 2016 AKW 15-010-048-01...
  • Page 10: Installing The Deflector Screen

    Technical Help line 01905 560219 www.akw-ltd.co.uk Step 4 Installing the deflector screen Installation Attach the bottom seal strip to the inside edge of the enclosure. inside Mount the seal strip on the bottom of the glass panel © 2016 AKW 15-010-048-01...
  • Page 11 Technical Help line 01905 560219 www.akw-ltd.co.uk Installing the deflector screen Ensure the bottom hinge is secured to the floor or tray. Attach the deflector screen onto the fixed panel hinges. Secure the top hinge bracket cover. © 2016 AKW 15-010-048-01...
  • Page 12: Step 5

    Mark out the position of tie bar bracket on the wall, make sure it is level and at 90 degrees to the screen face. Attach the tie bar mounting assembly to the top of the deflector screen. © 2016 AKW 15-010-048-01...
  • Page 13 Insert the tie bar into the tie bar socket. Drill a hole through the tie bar socket into the tie bar for the locking screw. Secure the tie bar into the socket with the self tapping 4x13mm screw. © 2016 AKW 15-010-048-01...
  • Page 14: Final Installation

    Secure the panel into its final position using the 4x10 screws. Do not over tighten screws. Clip on profile and panel cover caps Screw cap covers Finally check the levels and operation. © 2016 AKW 15-010-048-01...
  • Page 15 Note: The durability of the Stayclear protection may be affected by the frequency of use of ® the shower, hardness of the water and the type of cleaning compounds and methods used. Such matters are outside the control of the manufacturer. © 2016 AKW 15-010-048-01...
  • Page 16 These instructions are provided to advise the minimum standards of installation and recommends what is the best practice for the installation. Due to the very wide variability of possible installation conditions AKW cannot provide all circumstances for the installation. AKW cannot accept any liability in connection with this information or its use.