Download Print this page
Domintell D Max Blindmax BLE User Manual

Domintell D Max Blindmax BLE User Manual

Advertisement

Available languages

Available languages

Quick Links

Blindmax – User manual
The Blindmax module is able to supply power to bidirectional
command devices such as electrovans, motors, motorized
shutters,... controlled with 3 wires.
In order to configure the Blindmax, it is required to have one or
two external pushbuttons connected. It can be mounted behind
an already existing switch.
The module must have its own power supply (Phase, Neutral).
It can be used with the pushbutton and/or the Dmax app.
It can usually be used with the following modes: follower or trip
switch.
Wiring and configuration of the Blindmax
These steps must be carefully
followed:
Plug the Blindmax according to the
1.
hereby enclosed diagram (cut off
the 230V with the circuit breaker
first). The wiring is done via the
terminals.
The
different
modes
2.
Blindmax can be selected with the
Dmax application available for free
on Google Play or the Apple App
Store. After reconnecting the 230V,
do
a
scan
follow
carefully
authentication procedure to add the
corresponding Blindmax. Go to
settings to edit the operating modes.
For further details about the app,
see the user instructions available
at
www.dmaxbydomintell.com
Connect the output and validate it
3.
commutes correctly (the ex-factory setting of the Blindmax
allows commuting the output via a short push and maintaining
the state via a long push).
The Blindmax does not commute correctly (irregularly or
not at all)? Carefully read the tutorial available on the website.
Now adjust the Blindmax performance from the Dmax by
4.
Domintell app.
In case you have a question, see the detailed version at
www.dmaxbydomintell.com
Technical data
Item number
Type
Blindmax
5425014390308
BLE
EN_20190709
Foreword
of
the
and
the
full
or contact your supplier.
Contact maximum intensity
2 x 5 A max. 250 Vac
or 30 Vdc max.
Nominal conditions: 230V AC +/- 15%, 50 Hz, Ambient
temperature: -10°C to 40°C.
Maximum wiring section per contact = 2,5 mm².
1 self-resettable protection: against overcurrent and
temporary overheating.
IP20 protection level.
Without halogen, RoHS.
Storage conditions: Temperature: -25°C / +70°C, Relative
humidity: < 75%.
For a safe installation, the device can only be mounted
by a qualified electrician.
The device must not be opened in any case (cancels
warranty).
The device can only be installed inside, in a dry place,
compatible with IP20 devices.
During the mounting and unmounting of the device, cut
off the 230V circuit-breaker.
After installation, the connector must be protected so that
could not be accessible for the final user.
For a LONG PUSH (> 0,4s) on one of the two buttons: the
motor turns on and the Blindmax maintains its output ON as
long as the button is hold. The motor turns off when the
button is released.
For a SHORT PUSH (<0,4s) on the button: The Blindmax
commutes its output state, if it was OFF, it turns ON and vice-
versa. The motor remains ON for a time defined by the user
through the app.
The user can also choose using only a single button which
he configures through the app. With a short push, the motor
goes one way. On the next push, the motor goes the other
way. For a long push, the motor goes one way as long as the
button is pressed. On the next long push, the motor goes the
other way.
The Blindmax complies with the following directives and
standards:
Directives
RED-directive : 2014/53/UE
EMC-directive : 2014/30/UE
LV-directive : 2014/35/UE
Norm
EN 60669-2-1 : 2004 + A1: 2009 +A12: 2010
Dimensions
46 x 45 x 18
Blindmax
(mm)
is manufactured in Belgium by:
Domintell S.A.
dmaxbydomintell.com
Safety and environment
Pushbutton control
Directives and norms

Advertisement

loading

Summary of Contents for Domintell D Max Blindmax BLE

  • Page 1 Carefully read the tutorial available on the website. The Blindmax complies with the following directives and Now adjust the Blindmax performance from the Dmax by standards: Domintell app. Directives In case you have a question, see the detailed version at RED-directive : 2014/53/UE www.dmaxbydomintell.com...
  • Page 2 EN 60669-2-1: 2004 + A1: 2009 +A12: 2010 Blindmax Technische gegevens wordt in België geproduceerd door: Maximale Spanning Domintell S.A. Artikelnummer Type Afmeting van contact dmaxbydomintell.com 2 x 5 A max. 250 Vac...
  • Page 3 ? Lisez dans le détail le tutoriel disponible sur le site internet. Directives Ajustez maintenant le comportement du Blindmax depuis RED-directive : 2014/53/UE l'application Dmax by Domintell. EC-directive : 2014/40/UE LV-directive : 2014/35/UE En cas de question, voyez la version détaillée sur www.dmaxbydomintell.com...
  • Page 4 In diesen Fällen lesen Sie sich bitte die wird in Belgien hergestellt von : auf der Website befindliche Anleitung sorgfältig durch. Domintell S.A. Passen Sie nun die Blindmax-Einstellungen mittels der Dmax- www.dmaxbydomintell.com App an. Falls Sie Fragen haben, lesen Sie die ausführliche Version der Gebrauchsanweisung unter: www.dmaxbydomintell.com...

This manual is also suitable for:

5425014390308Dmax blindmax