Important Notes to the Installer
1. Read all instructions contained in these
installation instructions before installing the
cooktop.
2. Remove all packing material before connecting
the electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the
consumer.
5. All materials used in construction of cabinets,
enclosures, and supports surrounding the
product must have a temperature rating above
194°F (90°C).
Important Note to the Consumer
Keep these instructions with your User manual for
future reference.
IMPORTANT SAFETY
INSTRUCTIONS
Be sure your cooktop is installed and grounded
properly by a qualified installer or service
technician.
These cooktops must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA No.
70—latest edition in the United States, or with
CSA Standard C22.1, Canadian Electrical Code,
Part 1, in Canada.
WARNING!
The electrical power to the cooktop must
be shut off while line connections are
being made. Failure to do so could result in
serious injury or death.

Provide Electrical Connection

Install the junction box under the cabinet and run
120/240 or 120/208 Volt, AC wire from the main
circuit panel. DO NOT connect the wire to the circuit
panel at this time.

Electrical Requirements

This appliance must be supplied with the proper
voltage and frequency, and connected to an
individual, properly grounded branch circuit,
protected by a circuit breaker or fuse. A circuit
breaker or fuse is required by your appliance.
The circuit breaker or fuse amperage
recommended for your appliance is 40A or
50A.
6
Observe all governing codes and local
ordinances
1. A 3-wire or 4-wire single phase 120/240 or
120/208 Volt, 60 Hz AC only electrical supply
is required on a separate circuit fused on both
sides of the line (red and black wires). A time-
delay fuse or circuit breaker is recommended.
DO NOT fuse neutral (white wire). Only certain
cooktop models may be installed over certain
built-in electric oven models. Approved cooktops
and built-in ovens are listed by the MFG ID
number (see the insert sheet included in the
literature package).
2. The flexible armored cable extending from the
appliance should be connected directly to the
junction box. The junction box should be located
as shown in Figure 1 or Figure 2 and with as
much slack as possible remaining in the cable
between the box and the appliance, so it can be
moved if servicing is ever necessary.
3. A suitable strain relief must be provided to
attach the flexible armored cable to the junction
box.
NOTE: Wire sizes and connections must conform
with the fuse size and rating of the appliance in
accordance with the American National Electrical
Code ANSI/NFPA No. 70-latest edition, or with
Canadian CSA Standard C22.1, Canadian Electrical
Code, Part 1, and local codes and ordinances.
WARNING!
An extension cord must not be used with
this appliance. Such use may result in a fire,
electrical shock, or other personal injury.
Unpacking Instructions
1. Leave corner supports on cooktop until
completion of Electrical Connection.
2. It is important that the ceramic-glass
smoothtop be pretreated before use.
Rating plate
(under cooktop)
Figure 3