Download Print this page
First Alert SC01NM08 User Manual
First Alert SC01NM08 User Manual

First Alert SC01NM08 User Manual

Smoke and carbon monoxide alarm

Advertisement

USER'S MANUAL
SMOKE AND CARBON MONOXIDE ALARM
Features:
Separate sensors to detect smoke
and CO. The two alarm systems
work independently.
Powered by a single 9V alkaline or
lithium battery
Flip-open battery door for easy
battery replacement
Large, easy-to-use Test button
Colored lights indicate "battery
status" and "service needed."
IMPORTANT!
PLEASE READ CAREFULLY AND SAVE.
This user's manual contains important information about your Smoke/CO
Alarm's operation. If you are installing this Smoke/CO Alarm for use by
others, you must leave this manual-or a copy of it-with the end user.
M08-0015-000 Q 09/02
THIS USER'S MANUAL HAS BEEN RESIZED TO
PRINT OUT ON 8-1/2 x 11" PAGES.
BLACK page numbers reference the original printed document.
RED page numbers reference this web version.

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Where to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where This Alarm Should NOT Be Installed . . . . . . . . . . . . . . . . . . . . .2
How to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
If Your Smoke/CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
What To Do First-Identify The Type Of Alarm . . . . . . . . . . . . . . . . . . . .3
If the CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If the Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . . . .4
How Can I Protect My Family From CO Poisoning? . . . . . . . . . . . . . . .
Regulatory Information For Smoke/CO Alarms . . . . . . . . . . . . . . . . . . . . .5
Regulatory Information for CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . .5
Regulatory Information for Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . .5
Recommended Locations for Smoke Alarms . . . . . . . . . . . . . . . . . . . .5
About Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . . .
General Limitations Of Smoke/CO Alarms . . . . . . . . . . . . . . . . . . . .
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
All Rights Reserved. © 2002 BRK Brands, Inc.
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005 • www.firstalert.com
All First Alert
®
Smoke Alarms conform to regulatory requirements,
including UL217 and are designed to detect particles of combustion.
Smoke particles of varying number and size are produced in all fires.
Ionization technology is generally more sensitive than photoelectric
technology at detecting small particles, which tend to be produced
in greater amounts by flaming fires, which consume combustible
materials rapidly and spread quickly. Sources of these fires may include
paper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric technology is generally more sensitive than ionization
technology at detecting large particles, which tend to be produced in
greater amounts by smoldering fires, which may smolder for hours
before bursting into flame. Sources of these fires may include cigarettes
burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each
level of your home.

INTRODUCTION

FIRE SAFETY TIPS

Follow safety rules and prevent hazardous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters away
from children; 3) Store flammable materials in proper containers; 4) Keep
electrical appliances in good condition and don't overload electrical circuits;
5) Keep stoves, barbecue grills, fireplaces and chimneys grease- and debris-
free; 6) Never leave anything cooking on the stove unattended; 7) Keep
portable heaters and open flames, like candles, away from flammable
materials; 8) Don't let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if they
are not working properly. Smoke Alarms that do not work cannot alert you
to a fire. Keep at least one working fire extinguisher on every floor, and an
additional one in the kitchen. Have fire escape ladders or other reliable means
of escape from an upper floor in case stairs are blocked.

BASIC SAFETY INFORMATION

Model SC01N
.4/3
.5/4
.6/5
.7/6
.6-7/6
.6-7/7
.6-7/7
1
• Dangers, Warnings, and Cautions alert you to important
operating instructions or to potentially hazardous situations.
Pay special attention to these items.
• This Smoke/CO Alarm is approved for use in single-family
residences. It is NOT designed for marine or RV use.
• This combination Smoke/Carbon Monoxide Alarm has two separate
alarms. The CO Alarm is not designed to detect fire or any other gas.
It will only indicate the presence of carbon monoxide gas at the
sensor. Carbon monoxide gas may be present in other areas. The
Smoke Alarm will only indicate the presence of smoke that reaches
the sensor. The Smoke Alarm is not designed to sense gas, heat or
flames.
• This Smoke/CO Alarm cannot operate without a working battery.
Removing the battery for any reason, or failing to replace the battery
at the end of its service life, removes your protection.
• NEVER ignore any alarm. See "If Your Smoke/CO Alarm Sounds" for
more information on how to respond to an alarm. Failure to respond
can result in injury or death.
• The Silence Feature is for your convenience only and will not
correct a Smoke/CO problem. Always check your home for a
potential problem after any alarm. Failure to do so can result in
injury or death.
• Test this Smoke/CO Alarm once a week. If the Alarm ever fails to test
correctly, have it replaced immediately! If the Alarm is not working
properly, it cannot alert you to a problem.
• This product is intended for use in ordinary indoor locations of
family living units. It is not designed to measure CO levels in
compliance with Occupational Safety and Health Administration
(OSHA) commercial or industrial standards. Individuals with
medical conditions that may make them more sensitive to carbon
monoxide may consider using warning devices which provide
audible and visual signals for carbon monoxide concentrations
under 30 ppm. For additional information on carbon monoxide
and your medical condition contact your physician.

Advertisement

loading

Summary of Contents for First Alert SC01NM08

  • Page 1: Table Of Contents

    If the CO Alarm Sounds ........3 If the Smoke Alarm Sounds ....... . .3 Using the Silence Feature .
  • Page 2: Installation

    WHERE TO INSTALL THIS ALARM Minimum coverage for Smoke Alarms, as recommended by the National Fire Protection Association (NFPA), is one Smoke Alarm on every floor, in every sleeping area, and in every bedroom (See “Regulatory Information For Smoke Alarms” for details on the NFPA recommendations).
  • Page 3: How To Install This Alarm

    “chirp.” The “chirp” marks the start of the self-test sequence. • First, the BATTERY (green) and SERVICE (yellow) lights will flash • Next, the Smoke Alarm will sound. The smoke symbol will flash, and • Finally, the CO Alarm will sound. The CO symbol will flash, and you will If the unit does not alarm, make sure the battery is correctly installed, and test again.
  • Page 4: Regular Maintenance

    REGULAR MAINTENANCE Use only the replacement batteries listed below. The unit may not operate properly with other batteries. Never use rechargeable batteries since they may not provide a constant charge. This unit has been designed to be as maintenance-free as possible, but there are a few simple things you must do to keep it working properly: •...
  • Page 5: Regulatory Information For Smoke/Co Alarms

    Smoke Alarms must be AC powered and interconnected. See “Agency Placement Recommendations” for details. For additional cover- age, it is recommended that you install a Smoke Alarm in all rooms, halls, storage areas, finished attics, and basements, where temperatures normally remain between 40˚F (4˚C) and 100˚F (38˚C).
  • Page 6: Special Compliance Considerations

    CO or smoke reaches the sensors. If bedroom doors are usually closed at night, we recommend you install an alarm device (Combination CO and Smoke Alarm, or separate CO Alarms and Smoke Alarms) in each bedroom and in the hallway between them.
  • Page 7: Troubleshooting Guide

    CO are revealed in an investigation. Smoke Alarm ONLY: Smoke Alarm sounds when no smoke is visible. *For a list of acceptable replacement batteries, see “Regular Maintenance.” If you have questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005, M-F 7:30 a.m. to 5:00 p.m. (CST) BRK Brands, Inc., ("BRK") the maker of First Alert...

This manual is also suitable for:

Sc01n