Next generation frame, fiber termination block with mpo connectors (ftb w/mpo)

Advertisement

Quick Links

ADCP-90-372 Rev B April 2018
Next Generation Frame (NGF)
Fiber Termination Block With MPO Connectors (FTB w/MPO)
User Manual
ADCP-90-372 Rev B
www.commscope.com
26630-A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NGF-MPML0C112 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CommScope NGF-MPML0C112

  • Page 1 ADCP-90-372 Rev B April 2018 Next Generation Frame (NGF) Fiber Termination Block With MPO Connectors (FTB w/MPO) User Manual 26630-A ADCP-90-372 Rev B www.commscope.com...
  • Page 2 Contents herein are current as of the date of publication. CommScope reserves the right to change the contents without prior notice. In no event shall CommScope be liable for any damages resulting from loss of data, loss of use, or loss of profits and CommScope further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.
  • Page 3: Table Of Contents

    CUSTOMER INFORMATION AND ASSISTANCE ........... 16 Page iii © 2018, CommScope, Inc.
  • Page 4 ADCP-90-372 • Rev B • April 2018 • Preface TABLE OF CONTENTS Content Page Blank Page Page iv © 2018, CommScope, Inc.
  • Page 5: About This Month

    The procedures for installing the various NGF racks and accessories are provided in other CommScope publications (see “Related Publications,” below). RELATED PUBLICATIONS Listed below are related manuals and their publication numbers. Copies of these publications can be ordered by contacting the CommScope Technical Assistance Center using the URL: http://www.commscope.com/SupportCenter Title/Description ADCP Number...
  • Page 6: Admonishments

    LIST OF ACRONYMS AND ABBREVIATIONS The following acronyms are used in this manual: FMDF Fiber Main Distributing Frame Fiber Termination Block FTB w/MPO Fiber Termination Block With MPO Connectors Multifiber Push-on Connector Next Generation Frame Page vi © 2018, CommScope, Inc..
  • Page 7: Product Description

    ADCP-90-372 • Rev B • April 2018 1 PRODUCT DESCRIPTION This section describes the CommScope Fiber Termination Block with MPO Connectors (FTB w/MPO). The FTB w/MPO is available with 96, 144, or 192 terminations per block. General Description The FTB w/MPO is used on a NGF rack to provide a point for terminating MPO trunk cables.
  • Page 8: Product Function

    MPO trunk cables are located. The rear cable management area also has an upper radius limiter and other features designed for securing and routing a MPO trunk cable. Page 2 © 2018, CommScope, Inc.
  • Page 9: Options That Affect Installation

    50/125 um laser optimized to 300 m, 50/125 um. 62.5/125 um, and singlemode. • The FTB may be ordered any of several different types of connectors. For a complete list, refer to Table 1 on Page Page 3 © 2018, CommScope, Inc.
  • Page 10: Accessories

    A network element may be connected to a trunk cable, a network element may be connected to another network element, or a trunk cable may be connected to another trunk cable, using a cross-connect patch cord. Page 4 © 2018, CommScope, Inc.
  • Page 11: Specifications

    Use the following procedure to unpack and inspect the FTB w/MPO: 1. Inspect the exterior of the shipping container for evidence of rough handling that may have damaged the contents of the container. 2. Unpack the FTB and inspect for possible damage. Page 5 © 2018, CommScope, Inc.
  • Page 12: Mounting The Ftb On The Rack

    ADCP-90-372 • Rev B • April 2018 3. If damage is detected or if parts are missing, file a claim with the commercial carrier and then notify CommScope Customer Service (http://www.commscope.com/SupportCenter). Save damaged carton for inspection by carrier. 4. Even if no damage is evident, save the shipping container in case the equipment requires shipment at a future date.
  • Page 13: Mpo Trunk Cable Installation

    MPO trunk cables maybe routed into the FTB from either above or below the rack. Use the following procedure for routing and securing the MPO cable (see Figure 8 Figure Caution: Inspect each cable and clean the MPO connectors before connecting the cable. For instructions, refer to ADCP-90-379. Page 7 © 2018, CommScope, Inc.
  • Page 14 TIE ONE BLOCK ABOVE FURCATION 13.5-INCH 13.5-INCH SUB-UNIT SUB-UNIT FURCATION TIE OFF ON TIE NEXT TO BLOCK RACK TRUNK BOTTOM ENTRY TOP ENTRY 23870-A Figure 8. MPO Trunk Cable Routing Into FTB (Rear View) Page 8 © 2018, CommScope, Inc.
  • Page 15 MPO 1 FOR BOTTOM ENTRY, PLACE AND SECURE CABLES AS SHOWN. FRAME MAY BE POPULATED FROM THE BOTTOM OR TOP. 22643-A BOTTOM ENTRY Figure 9. Routing MPO Trunk Cables on NGF Rack (Side View) Page 9 © 2018, CommScope, Inc.
  • Page 16: 12-Strand Mpo Cable Installation

    11. This is the point at which the cable will be tied to the rack. 2. Route the MPO cable from above or below the rack as shown in Figure 13.5 IN. (34.3 CM) TIE-OFF POINT CONNECTOR 22721-A Figure 11. Marking Out Tie-Down Point Page 10 © 2018, CommScope, Inc.
  • Page 17 MPO 1 FOR BOTTOM ENTRY, PLACE AND SECURE CABLES AS SHOWN. FRAME MAY BE POPULATED FROM THE BOTTOM OR TOP. 22722-A BOTTOM ENTRY Figure 12. Routing MPO 12-Strand Cables on NGF Rack (Side View) Page 11 © 2018, CommScope, Inc.
  • Page 18 TIE OFF ON TIE ONE BLOCK ABOVE 13.5-INCH 13.5-INCH SUB-UNIT SUB-UNIT TIE OFF ON TIE NEXT TO BLOCK 12-STRAND RACK CABLE BOTTOM ENTRY TOP ENTRY 23871-A Figure 13. MPO Trunk Cable Routing Into FTB (Rear View) Page 12 © 2018, CommScope, Inc.
  • Page 19: Patch Cord Installation

    1. To ready the FTB for connecting a patch cord, open the door and slide out the desired adapter pack as shown in Figure 23873-A ADAPTER PACKS DOOR Figure 14. Sliding Out an Adapter Pack Page 13 © 2018, CommScope, Inc.
  • Page 20 Figure HORIZONTAL REAR TROUGH TO FTB IN DIFFERENT FRAME WITHIN SAME LINEUP 23875-A TO FTB IN DISTRIBUTION SAME FRAME TROUGH RADIUS LIMITERS Figure 16. Routing the Patch Cord in the Distribution Trough Page 14 © 2018, CommScope, Inc.
  • Page 21 Figure 17. Patch Cord Routing on Front of Rack 5. For specific routing instructions, refer to the laminated cards handing on the rack (ADCP- 90-240, Fiber Main Distribution Frame (FMDF) Interconnect and Cross-Connect Patch Cord Routing Guide). Page 15 © 2018, CommScope, Inc.
  • Page 22: Customer Information And Assistance

    7 CUSTOMER INFORMATION AND ASSISTANCE Visit our website or contact your local CommScope representative for more information. • To find out more about CommScope® products, visit us on the web at www.commscope.com • For technical assistance, customer service, or to report any missing/damaged parts, visit us http://www.commscope.com/SupportCenter...
  • Page 23 ADCP-90-372 • Rev B • April 2018 Page 17 © 2018, CommScope, Inc.