GB Slug-Out 90T Instruction Sheet

Advertisement

Quick Links

Gardner
Bender
I MPORTANT RECEIVING INSTRUCTIONS: Visually inspect all components for shipping damage. If any shipping damage
is found, notify carrier at once. Shipping damage is NOT covered by warranty. The carrier is responsible for all repair or
replacement costs resulting from damage in shipment.
I MPORTANT — USER SAFETY AND PROTECTION: In setting up systems to fit your operations, care must be taken to
select the proper components and design to insure appropriate integration with your operations and existing equipment and
that all safety measures have been taken to avoid the risk of personal injury and property damage from your application
or system.
GB ELECTRICAL CANNOT BE RESPONSIBLE FOR DAMAGE OR INJURY CAUSED BY UNSAFE USE, MAINTENANCE
OR APPLICATION OF ITS PRODUCTS. Please contact GB Electrical for guidance when you are in doubt as to the proper
safety precautions to be taken in designing and setting up your particular application.
To prevent injury keep hands away from the punch and die while punching holes. Always wear
!
WARNING
approved eye protection.
Avoid dropping the cylinder. During punch operation, support the cylinder to prevent it from
falling after punching is completed.
To prevent thread damage, be sure punch is threaded onto the stud until the stud extends
beyond the punch. Make sure all rods, studs and punches are secured before operating
hydraulic driver.
Do not operate near live circuits. Contact with live circuits can cause injury or death.
Never exceed rated capacity of the tool. Use this tool for its intended use only.
Never operate the pump lever after the ram motion stops. Continued operation after ram motion
stops will damage driver and could result in injury.
Note: Inspect tool and components for wear & damage. Replace worn, damaged, or missing components with genuine
GB replacement parts. To ensure ease of assembly & operation, keep all threads clean & lightly oiled.
Slug-Out 90
Features
• Four-point punches for easy slug removal.
• Right-angle head swivels 360
in tight work spaces.
KOS5290 Kit Components:
Model
KLP6
KPR7520
KPS50
KSA50
Z88010
KP500B
KD500B
KP750B
To Protect Your Warranty, Use Only Enerpac Hydraulic Oil.
Instruction
1
TM
" - 2" Self-contained Right-angle Hydraulic Knockout Set
2
o
for flexible punching
Description
Hydraulic Driver
Pull Rod
Pull Stud
Pull Stud Adapter
Storage Case
1
" Punch
2
1
" Die
2
3
" Punch
4
Sheet
1
• Punches up to 2
" conduit sizes in up to 12-gauge
2
stainless or 10-gauge mild steel.
• Compact, lightweight size: 7
• Operating pressure rated at 10,000 psi.
Model
KPD750B
KP1000B
KD1000B
KP1250B
KD1250B
KP1500B
KD1500B
KP2000B
KD2000B
Slug-Out 90
TM
1
pounds and 13" long.
2
Description
3
" Die
4
1" Punch
1" Die
1
1
" Punch
4
1
1
" Die
4
1
1
" Punch
2
1
1
" Die
2
2" Punch
2" Die

Advertisement

loading

Summary of Contents for GB Slug-Out 90T

  • Page 1 GB ELECTRICAL CANNOT BE RESPONSIBLE FOR DAMAGE OR INJURY CAUSED BY UNSAFE USE, MAINTENANCE OR APPLICATION OF ITS PRODUCTS. Please contact GB Electrical for guidance when you are in doubt as to the proper safety precautions to be taken in designing and setting up your particular application.