+44 (0)1204 699 959 enquiries@hyquip.co.uk www.hyquip.co.uk/web/index Analog Command Value Card VT-SWKA-1 Product Description and Commissioning Instructions RE 30 255-B/05.00 Hyquip Limited New Brunswick Street Horwich Bolton Lancashire BL6 7JB UK Company Registered in England No: 4167649 VAT Registration No: 732 5692 25 BS EN ISO 9001:2008 No: LRQ 0964389...
+44 (0)1204 699 959 enquiries@hyquip.co.uk www.hyquip.co.uk/web/index Product description and commissioning instructions VT-SWKA-1 Table of contents Table of contents 1. General 1.1 Features 1.2 Technical data 2. Block circuit diagram 3. Functional description / commissioning notes 3.1 General 3.2 Command value preselection 3.3 Current input 3.4 Command value call-ups 3.5 External command value potentiometer...
+44 (0)1204 699 959 enquiries@hyquip.co.uk www.hyquip.co.uk/web/index Product description and commissioning instructions VT-SWKA-1 1. General 1. General 1.1 Features – Analog command value card (without power part) for controlling valves with integral electronics → For controlling valves without integral electronics, a suitable additional amplifier is required.
+44 (0)1204 699 959 enquiries@hyquip.co.uk www.hyquip.co.uk/web/index Product description and commissioning instructions VT-SWKA-1 3. Functional description / commissioning notes 3. Functional description / 3.1 General The command value card is designed as printed circuit board in Euro-format 100 x 160 mm commissioning notes and is suitable for installation in a rack.
+44 (0)1204 699 959 enquiries@hyquip.co.uk www.hyquip.co.uk/web/index Product description and commissioning instructions VT-SWKA-1 3. Functional description / commissioning notes 3.8 Ramp generator [9] The ramp generator limits the increase of the control variable. Downstream step-functions and amplitude attenuators do not shorten or extend the ramp time. Jumper J2 can be used to set the ramp time to minimum (<...
+44 (0)1204 699 959 enquiries@hyquip.co.uk www.hyquip.co.uk/web/index Product description and commissioning instructions VT-SWKA-1 3. Functional description / commissioning notes 3.11 Ramp time selection logic [10] a) Operating mode "4-quadrant operation" When 4-quadrant operation is activated (24V signal “4Q”), the electronics automatically recognizes the command value polarity and the direction of change of the command value and assigns a ramp time to the current signal status.
+44 (0)1204 699 959 enquiries@hyquip.co.uk www.hyquip.co.uk/web/index Product description and commissioning instructions VT-SWKA-1 3. Functional description / commissioning notes 3.14 Fault recognition [14] This features monitors internal operating voltages, voltage outputs and, if jumper J7 (1-2) is plugged, the current output for cable break. When no fault is present, the green “ready for operation”...
+44 (0)1204 699 959 enquiries@hyquip.co.uk www.hyquip.co.uk/web/index Product description and commissioning instructions VT-SWKA-1 5. Adjustment recommendation 5. Adjustment recommendation The system-specific circuit must be provided. Signal Adjustment Command value call-up – Select the potentiometer to be adjusted using the measuring point selector switch –...