Advertisement

Quick Setup Guide
EdgeIPS
SECURED BY
1
3
PORT
2
4
BP
1-2
3-4
1
3
PORT
2
4
PWR1
PWR2
STATE
MGMT
HA
USB
HA
MGMT
BP
1-2
3-4
FAIL
OIOI
MR
RESET
EdgeIPS Pro-2096 is a Transparent Security
Appliance. Support up to 24 pair IPS segments,
Users can efficiently adapt the rack mount-sized
EdgeIPS Pro-2096 into a flexible solution for the
challenges of Ethernet communications.
1
1
Opening and Inspecting the Package
SECURED BY
EdgeIPS Pro -1048
SECURED BY
EdgeIPS Pro-2096 Appliance
M5
M4
x10
x5
Rail Mount Kit
(EdgeIPS Pro-2096)
2
1
Examining the EdgeIPS Pro-2096
SECURED BY
1
3
PORT
2
4
BP
1-2
3-4
1
3
PORT
2
4
PWR1
PWR2
STATE
MGMT
HA
USB
HA
MGMT
BP
1-2
3-4
FAIL
OIOI
MR
RESET
Pro-2096
TM
SLOT1
SLOT3
5
7
9
11
13
15
17
19
6
8
10
12
14
16
18
20
5-6
7-8
9-10
11-12
13-14
15-16
17-18
19-20
5
7
9
11
13
15
17
19
6
8
10
12
14
16
18
20
5-6
7-8
9-10
11-12
13-14
15-16
17-18
19-20
x2
Power Cord x 2
SLOT1
SLOT3
5
7
9
11
13
15
6
8
10
12
14
16
5-6
7-8
9-10
11-12
13-14
15-16
17-18
5
7
9
11
13
15
6
8
10
12
14
16
5-6
7-8
9-10
11-12
13-14
15-16
17-18
EdgeIPS Pro-2096 Front Panel
23
1
3
5
7
9
21
PORT
22
24
2
4
6
8
10
21-22
23-24
BP
1-2
3-4
5-6
7-8
9-10
23
1
3
5
7
9
21
PORT
22
24
2
4
6
8
10
21-22
23-24
BP
1-2
3-4
5-6
7-8
9-10
Console Cable
(USB-Type-C)
17
19
23
1
3
21
PORT
18
20
22
24
2
4
19-20
21-22
23-24
BP
1-2
3-4
17
19
21
23
1
3
PORT
18
20
22
24
2
4
19-20
21-22
23-24
BP
1-2
3-4
1
-
-
SLOT2
SLOT4
11
13
15
17
19
23
21
12
14
16
18
20
22
24
11-12
13-14
15-16
17-18
19-20
21-22
23-24
11
13
15
17
19
23
21
12
14
16
18
20
22
24
11-12
13-14
15-16
17-18
19-20
21-22
23-24
Power Cord Strain Relief Kit
Documents
SLOT2
SLOT4
5
7
9
11
13
15
6
8
10
12
14
16
5-6
7-8
9-10
11-12
13-14
15-16
17-18
5
7
9
11
13
15
6
8
10
12
14
16
5-6
7-8
9-10
11-12
13-14
15-16
17-18
17
19
23
21
18
20
22
24
19-20
21-22
23-24
17
19
21
23
18
20
22
24
19-20
21-22
23-24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EdgelIPS Pro-2096 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Trend Micro EdgelIPS Pro-2096

  • Page 1 Quick Setup Guide EdgeIPS Pro-2096 SLOT1 SLOT3 SLOT2 SLOT4 SECURED BY PORT PORT 9-10 11-12 13-14 15-16 17-18 19-20 21-22 23-24 9-10 11-12 13-14 15-16 17-18 19-20 21-22 23-24 PORT PORT PWR1 PWR2 STATE MGMT MGMT 9-10 11-12 13-14 15-16 17-18 19-20 21-22...
  • Page 2: Deployment Checklist

    Deployment Checklist Requirement Details Ethernet Cables Connect to the Management Port for accessing web console management. Default IP Address of Default web console access information: Web Console https://192.168.127.254 User Name: admin Password: txone Laptop with Ethernet The computer must have one of the following browsers installed: Port (RJ-45 Type) - Microsoft Edge (version 15 or above) - Firefox (version 53 or above)
  • Page 3: Led Indicators

    LED Indicators The function of each LED is described in the table below Green Power 1 is on, and device is functioning normally PWR1 Power 1 is off Green Power 2 is on, and device is functioning normally PWR2 Power 2 is off Green System is running normal STATE...
  • Page 4 Installing the EdgeIPS Pro The aluminum Rail attachment plate should already be fixed to the back panel of the EdgeIPS Pro-2096 when you take it out of the box. If you need to reattach the Rail attachment plate to the EdgeIPS Pro-2096, make sure the stiff metal spring is oriented towards the top, as shown in the following pictures.
  • Page 5 Step Release safety lock before mounting Push the safety lock forward to secure Step Retainer is in fully open position Step Press trigger down to release the slides from locking...
  • Page 6: Wiring The Redundant Power Inputs

    Wiring the Redundant Power Inputs Wiring the Redundant Power Inputs The Trend Micro EdgeIPS Pro has two sets of power inputs – power input1 and power input2. The top and side views of the terminal block connector are shown below.
  • Page 7 Wiring the Redundant Power Inputs Software Configuration Before connecting the PC/Laptop to EdgeIPS Pro-2096, the PC's IP address should be set to 192.168.127.100. After that, connect the PC and EdgeIPS Pro-2096 using an Ethernet cable. Open a web browser on your PC and type “https://192.168.127.254” into the address bar. A pop-up window will open to ask for user name and password.
  • Page 8 Setting the Management IP Address 1. Go to [Network] > [Device Settings] 2. In the [Network Setting] plane, configure management IP address for EdgeIPS Pro Task Action Device IP Address Configure Management IP Address of the EdgeIPS Pro Netmask Configure Netmask of the EdgeIPS Pro Gateway Confiture GatewayAddress of the EdgeIPS Pro Configure DNS setting of the EdgeIPS Pro...
  • Page 9 Checking the LED to Confirm Status The LED on each Ethernet port shows the deployment status. No Light The EdgeIPS Pro appliance cannot communicate with a network. Left LED GE LINK/ACT (off = no link, on = activity) Right LED 10 Gbps LINK/ACT (on = 10 Gbps link) MGMT/MR Right LED...
  • Page 10: Contact Information

    EdgeIPS Pro Datasheet/Application Note Landing Page © 2021 Trend Micro Incorporated. All Rights Reserved. Trend Micro and the t-ball logo are trademarks or registered trademarks of Trend Micro Incorporated. All other company and/or product names may be trademarks or registered trademarks of their...

This manual is also suitable for:

Txone edgeips pro-1048

Table of Contents