Operation & Maintenance Manual D MISTER VERTICAL OIL MIST COLLECTOR READ AND SAVE THESE INSTRUCTIONS Visit our Website for more information on this product www.diversitech-air.com www.diversitech.ca 1200 55 Avenue, Montreal, Quebec H8T 3J8 Tel: 1-800-361-3733 | Fax: 1-514-631-9480 | info@diversitech.ca...
TABLE OF CONTENTS Safety …………………...……………………......................................................……………. 3 Inspection ................................................................... 3 Specifications ……………….……………..................................................……….……………………... 4 Installation …………………………………........………............................................…………………… 5 Replacement Parts ………………………................................................………….……………………. 6 Optional Direct Drive Replacement Parts ....................................................7 3 Phase Electrical Diagram ......…............................................…………..……………………. 8 Motor Mounting ..............................................................9 Connecting Power to Motor ........................................................10 Motor Troubleshooting Chart ….…....…............................................…………….…………..….
INSPECTION Upon receiving your Diversitech air cleaner, please inspect for any damage incurred during shipment. Inspect carefully, some damage may not be noticeable until the unit is installed. Notify your shipper of any damage immediately. Claims must be filed with the shipper within 15 days. Freight damage claims are the responsibility of...
Units are typically mounted on the optional floor stand or rod hanging brackets illustrated in Figure 2. Duct work may be required to complete installation which is not supplied by Diversitech. Consult your dealer or the factory for the correct materials to use for your application. A qualified mechanical contractor should be used to ensure unit installation meets all applicable building codes.
3 PHASE ELECTRICAL WIRING DIAGRAM Standard 115v unit comes wired to a toggle switch with 15 ft cord, see figure 5 above. 230 V single phase units are factory wired to a junction box on the side of the cabinet, switch not included. Additional wiring will be required to get power to unit, which is not supplied with this product.
Motor Mounting Motor must be securely fastened to a rigid, flat surface to prevent vibration and minimize noise. For secure mounting use high-quality bolts of the largest possible diameter. Belt-drive sheaves must be in-line. Use a straight edge to check. Do not over-tighten belts. Direct coupled installations require a careful check of shaft and coupling alignment, shaft offset and/or angular misalignment should be less than .002”.
Connecting Power to Motor To connect motor for proper voltage and rotation, refer to the connection diagram on the nameplate or inside the terminal/conduit box. Table B - Minimum Wire Sizes for Single Phase Motors Motor 25 Feet 50 Feet 100 Feet 150 Feet 200 Feet...
Table C - Suggested Regreasing Intervals Motor HP at 1800 RPM Max. Type of Service Under 50 50 to 100 Over 100 Infrequent operation or light duty in clean atmosphere 2 Years 2 Years 1 Years 8 to 16 hours per day in clean, relatively dry atmosphere 2 Years 1 ½...
Motor Troubleshooting (cont.) Symptom Possible Cause(s) Corrective action Motor vibrates or is 1. Motor shaft misaligned 1. Realign excessively noisy 2. 3-phase motor running on single phase 2. Check for open circuit, blown fuses or unbalanced voltages 3. High or unbalanced voltages 3.
BLOWER TROUBLESHOOTING CHART Symptom Possible Cause(s) Corrective Action Excessive noise and/or 1. Foreign object 1. Remove vibration 2. Wheel rubbing on housing 2. Center the wheel 3. Loose wheel or sheave on shaft 3. Tighten all set screws 4. Motor or blower not secure 4.
Prior to the return of material, for whatever reason, a return merchandise authorization number (“RMA#”) is required from our customer service department. This procedure is necessary for proper control and handling of returned materials. Call 1-800-361-3733 or email support@diversitech.ca to obtain a RMA #. All material must be returned prepaid. Credit will be given for returns for warranty repair or replacement. Freight collect shipments will not be accepted.
Page 19
FEES AND CANCELLATION CHARGES 5.1. You will be responsible for any additional charges and fees not expressly included in the Sales Order, including, without limitation, any fees or charges relating to installation, service calls, consulting, installation, customization, “right-sizing”, engineering, maintenance and/or repair. For greater certainty, unless expressly provided in the Sales Order, we do not provide you with any form of service with respect to Units, including, without limitation, installation, repair and maintenance services.
For full product support, visit our website; https://bit.ly/2q7UC4v Scan above on mobile An Absolent Group Company 1200 55 Avenue Montreal, Quebec H8T 3J8 Email: info@diversitech.ca...
Need help?
Do you have a question about the D MISTER and is the answer not in the manual?
Questions and answers