UH209
H I G H P R E S S U R E F I LT E R S
1

Specifications

Housing materials:
Head:
Ductile cast iron
Bowl:
Carbon steel
Cage:
Steel, with corrosive resistant plating
Maximum operating pressure:
350 bar (5,075 psi)
Proof pressure:
525 bar (7,615 psi)
Typical burst pressure:
1050 bar (15,225 psi)
Element burst pressure:
UE209 element 10 bard (150 psid) differential minimum
Operating temperature range:
-29°C to 120°C (-20°F to 250°F) with fluorocarbon
seals for petroleum based and specified synthetic fluids
60°C (140°F) maximum in HWCF, water-oil emulsion
or water glycol
Bypass valve setting options:
4.5 ± 0.3 bard (65 ± 5 psid) cracking pressure
CAUTION:
Maximum surge flow should not exceed 1.3 times
normal flow.
Seals:
Fluorocarbon
The actual operating conditions should be checked by the user
to ensure that the element, housing and all seals are
compatible with the fluid and application, and are within local
safety codes. Please contact Pall or an approved distributor if
further information is required.
2

Receipt of equipment

The filter housing, and any optional equipment, are packed
individually for assembly by the customer. Unpack carefully
and ensure optional items are not mislaid in packaging to
be discarded.
3
General sources of information
3.1
For dimensions, operating parameters,
assembly/element part number, ordering information,
notes, performance data and specifications refer to
datasheet IMUH209EN.
3.2
This equipment has been assessed in accordance with
the guidelines laid down in the European Pressure
Directive 97/23/EC and has been classified within sound
engineering practice S.E.P. We hereby declare the
equipment meets the requirements of article 3, section
3, thus meeting the directive requirements. Under the
provisions of this directive the filter assembly is suitable
for use with group 2 fluids only.
3.3
Where under reasonably foreseeable conditions,
including external fires, the allowable limits could be
exceeded, suitable protective devices must be installed
by the customer within the connecting fluid system.
UH209 Series
s e r v i c e i n s t r u c t i o n s
4
Installation of housing
4.1
The filter can be installed in any attitude, but for ease of
servicing, it is recommended that it be installed vertically
with the filter bowl pointing downwards.
4.2
The minimum clearance for element removal is
60mm (2.4") for all lengths.
4.2.1 The UH209 series housing is supplied without
a filter element. For element installation and
servicing procedures, refer to Section 7.
4.3
Threaded differential pressure devices, when fitted, must
be torque tightened to 38 ft/lb or 54 Nm.
All visual indicators must be clearly visible
NOTE: The UH209 head is supplied with one machined
differential pressure warning port fitted with a plastic shipping
plug. If no differential pressure warning device is to be
installed, the shipping plug must be removed and replaced
with a 'B' type blanking plug (HA9000A104Z) and torque
tightened to 38 ft/lb or 54 Nm.
NOTE: Never install the port plug in the port without first
installing uniform size -014 O-ring in lower O-ring groove,
otherwise a small bypass flow will result, allowing contaminant
downstream of the filter element.
CAUTION:
Never operate the filter unless both warning device
ports are sealed.
4.4
Mount the filter assembly in position using three 5/16"-
UNC 2B ('A' ports) or M8 x 1.5 ('C' ports) bolts in the
holes on the head mounting pads. Torque bolts to
9-19 ft/lb or 12-26 Nm.
4.5
Use a check valve downstream of the filter if there is a
possibility of reverse flow.
4.6
Install the filter housing using additional piping/valving to
allow complete filter assembly bypass if filter maintenance
is required without system shutdown. This series is not
available in a duplex or service bypass configuration.
CAUTION:
Reverse flow through filter element will cause damage.
NOTE: Piping supports should be provided as close as is
practicable to the port connections in order to minimize
external loads. This filter assembly must not be electronically
isolated from the users earthing system. This filter assembly
must be earthed by connecting the users earthing system to
one of the inlet/outlet connections.
4.7
Connect lines or hoses to housing inlet and outlet ports.
WARNING:
USE FITTINGS OR ADAPTORS COMPATIBLE WITH
PORTS SUPPLIED AS SHOWN BY PART NUMBER ON
NAMEPLATE AND NOTED IN DATA SHEETS: USE OF
INCORRECT FITTINGS OR ADAPTORS CAN CAUSE
FILTER HOUSING OR MANIFOLD FAILURE
RESULTING IN LOSS OF PRESSURE AND POSSIBLE
SYSTEM FAILURE OR PERSONAL INJURY.
Note: Painting of the filter housing is optional. The coating on
the filter housing is a suitable painting base. Cover the
differential pressure warning device and nameplate if painting
of the housing takes place.
CAUTION:
Failure to bleed the filter housing adequately will
increase the dissolved air content of the system fluid
which will shorten fluid life and may cause other
problems in the system.
2