1. General Information These instructions should be read carefully and retained for further reference and maintenance. 2. Safety • Before installation or maintenance, ensure the mains supply to the luminaire is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
• CE Compliant • EC Directives: Conforms to latest directives • Dimensions: 180mm Diameter x 55mm • Mounting Hole Centres: 134mm Note: The high-frequency output of this sensor is <0.2mW, that is just one 5000th of the transmission power of a mobile phone or the output of a microwave oven.
5. Installation • Ensure the mains supply is switched off and the circuit supply fuses are removed or the circuit breaker turned off. • An isolating switch should be installed to the switch the power ON and OFF to the luminaire. This allows the unit to be easily switched OFF for maintenance purposes.
6. Connection Diagram • Connect the 230V AC 50Hz mains supply to the terminals as marked below; 230V~50Hz MAINS SUPPLY ISOLATION SWITCH Live Supply (Brown or Red) to Neutral Supply (Blue or Black) to...
Page 6
7. Setting Up • Take note of the 3 adjusters located beneath the diffuser/lens; • By default the 3 adjusters will be set as follows in order for you to complete a full walk test (from powering the unit ON for the first time); TIME fully anticlockwise to its minimum (approx.
Page 7
Setting Up for Automatic Operation • With the walk tests complete, the luminaire can be set up for automatic operation. • Use a thin flat blade screwdriver to make the adjustments. TIME – Time ON Delay Setting • The TIME setting controls how long the unit remains illuminated following activation and after all motion ceases.
Page 8
LUX – Light Control Setting • The LUX control determines the level of darkness required for the unit to start operating. • Turn it fully anti-clockwise to select full dusk until timed OFF operation (approx. 10 Lux). • Turn it fully clockwise to select full daytime until timed OFF operation (approx.
Page 9
SENS – Detection Range Setting • The SENS control setting determines the range of detection produced with the luminaire mounted at an optimum height of 2.5 metres. • Turn it fully anti-clockwise to select the minimum detection range of approx. 1 metre radius. •...
8. Troubleshooting Problem Solution • The luminaire Check the LUX light control setting is not set in the wrong will not switch ON position according to the current light level. Adjusting the setting (fully clockwise for day and night operation) and test again.
Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a...
Page 12
Timeguard directly prior to installation. If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline; HELPLINE 020 8450 0515 or email helpline @ timeguard.com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.