Greenlee Quick Draw 7804SB Manual

Greenlee Quick Draw 7804SB Manual

Hydraulic punch drivers
Hide thumbs Also See for Quick Draw 7804SB:

Advertisement

Hydraulic Punch Drivers
999 4730.7
INSTRUCTION MANUAL
7804SB / 7806SB
Quick Draw
®
7704SB / 7706SB
Quick Draw Flex™
Quick Draw
Serial Codes AHJ, YZ, and ZA
Read and understand all of the instructions and
safety information in this manual before operating
or servicing this tool.
© 2002 Greenlee Textron
7904SB / 7906SB
Quick Draw 90
®
®
8/02

Advertisement

Table of Contents
loading

Summary of Contents for Greenlee Quick Draw 7804SB

  • Page 1 Quick Draw Flex™ Quick Draw ® Hydraulic Punch Drivers Serial Codes AHJ, YZ, and ZA Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. 999 4730.7 © 2002 Greenlee Textron 8/02...
  • Page 2: Table Of Contents

    7904SB / 7906SB: Publication 999 4731.5 All specifications are nominal and may change as design improve- ments occur. Greenlee Textron shall not be liable for damages resulting from misapplication or misuse of its products. Quick Draw Flex is a trademark and Quick Draw, Quick Draw 90, Slug-Buster, and Slug-Splitter are registered trademarks of Greenlee Textron.
  • Page 3: Important Safety Information

    Failure to observe this warning can result in severe injury or death. Greenlee Textron / Subsidiary of Textron Inc. 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815/397-7070...
  • Page 4 All of the punch threads must be engaged by the draw stud threads. Incomplete assembly could cause a component failure. • Use only Greenlee punches, dies, and draw Use this tool for the manufacturer’s intended pur- studs. Other manufacturers’ components might pose only.
  • Page 5: Specifications

    Recommended Fluid ..............Greenlee hydraulic oil Miscellaneous Operating Temperature ..........–12 °C to 43 °C (10 °F to 110 °F) Operating Position .................. No restrictions Greenlee Textron / Subsidiary of Textron Inc. 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815/397-7070...
  • Page 6: Capacity And Draw Stud Selection Guide

    3/8" Draw Stud Spacer Adapter 29451 1924AA 7/16" Draw Stud Spacer 1924AA 31872 Spacer 3/4" Draw Stud 31872 3/4" Draw Stud 1924AA 33967 Spacer Adapter Greenlee Textron / Subsidiary of Textron Inc. 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815/397-7070...
  • Page 7: Operation

    “step-up punching.” After enlarging the pilot hole, the 3/4" draw stud is used to punch the final hole. Greenlee Textron / Subsidiary of Textron Inc. 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815/397-7070...
  • Page 8: Maintenance

    Wipe the bladder clean of excess oil and reassemble the reservoir handle. Reservoir Handle Lever Handle Bladder Plug Rubber Bladder Release Valve Knob Greenlee Textron / Subsidiary of Textron Inc. 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815/397-7070...
  • Page 9: Troubleshooting

    Guide.” Pump does not build Air in system. Refer to step 3 of “Adding Hydraulic Oil” in the pressure. “Maintenance” section. Greenlee Textron / Subsidiary of Textron Inc. 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815/397-7070...
  • Page 10: Draw Studs And Accessories

    Screw, 3/8" short adapter 33967 503 3967.2 Adapter, stud, 3/8–24 x 3/4–16 Greenlee Textron / Subsidiary of Textron Inc. 4455 Boeing Drive, Rockford, IL 61109-2988 USA Customer Service (International): 815/397-7070 • Fax: 815/397-9247 Customer Service (North America): 800/435-0786 • USA Fax: 800/451-2632, 815/397-1865 Canada Fax: 800/524-2853 www.greenlee.textron.com...

Table of Contents