Outback FLEXnet DC Overview Manual

Outback FLEXnet DC Overview Manual

Battery monitor

Advertisement

Quick Links

Contact Information
About OutBack Power
OutBack Power is a leader in advanced energy conversion technology. OutBack Power products include true
sinewave inverter/chargers, maximum power point tracking charge controllers, and system communication
components, as well as circuit breakers, batteries, accessories, and assembled systems.
Contact Information
Mailing Address:
1628 – West Williams Drive
Phoenix, AZ 5027 USA
Web Site:
www.outbackpower.com
Disclaimer
UNLESS SPECIFICALLY AGREED TO IN WRITING, OUTBACK POWER:
(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL
OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION.
(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT,
NDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH
INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER'S RISK.
OutBack Power cannot be responsible for system failure, damages, or injury resulting from improper
installation of their products.
Notice of Copyright
FLEXnet DC Battery Monitor Overview Guide © 2020 by OutBack Power Technologies, Inc.
All Rights Reserved.
Trademarks
Trademarks and logos are the property of OutBack Power Technologies, Inc. and its affiliates unless
otherwise noted. Subject to revisions without notice. E. & O.E. UL is a registered trademark of UL LLC.
IEEE is the registered trademark of The Institute of Electrical and Electronics Engineers, Inc.
Date and Revision
August 2020, Revision C
Part Number
900-0093-01-00 Rev C
Overview Guide
FLEXnet DC Battery Monitor
Introduction
OutBack Power's FLEXnet DC (FN-DC) is a battery monitoring
device that serves as a window to the battery bank. By
tracking battery voltage and the amount of incoming and
outgoing current, the FN-DC indicates the battery bank's state of
charge (SOC) and enables users to precisely confi gure charging
parameters to maximize battery performance and lifespan.
The FN-DC also provides an auxiliary relay that can activate a
ventilation fan, low-battery warning alarm, or other low-voltage
DC device. The MATE3s can use the FN-DC's information to
stop all charging devices when the batteries are full.
Contents
Specifi cations
2
Installation
3
Wiring
4
Programming
6
Monitoring
8
Operation
12
Example Use Cases
16
Troubleshooting Guide
18
Calibration
19
C
A
D
E
B
Included
A: FLEXnet DC
B: 10-pin Wiring Block
C: 6' CAT5 cable for HUB connection
D: 10' Twisted-Pair (TP) cable for battery connection
E: Three 6' TP cables for shunt connections
F: Two #6 × ⅜" pan head machine screws (not pictured)
G: Colored labels (not pictured)
IMPORTANT:
This document provides instructions for installation, setup, and
operation of the product. These instructions are for use by
qualifi ed personnel who meet all local and governmental code
requirements for licensing and training for the installation of
electrical power systems with AC and DC voltage up to 600 volts.
Failure to install or use this equipment as instructed in the
literature can result in damage to the equipment that may not
be covered under the limited warranty. This product is only
serviceable by qualifi ed personnel.
NOTES:
For programming and full functionality, this product requires
the use of an OutBack Power system display such as the
MATE3s. It is intended to monitor systems with OutBack
Power inverters, charge controllers, and related products.
This document assumes knowledge of features, functions,
and operation of other OutBack Power products. Consult
appropriate literature as necessary.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLEXnet DC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Outback FLEXnet DC

  • Page 1 About OutBack Power Introduction OutBack Power is a leader in advanced energy conversion technology. OutBack Power products include true sinewave inverter/chargers, maximum power point tracking charge controllers, and system communication components, as well as circuit breakers, batteries, accessories, and assembled systems.
  • Page 2: Specifications

    3.7" (9.4 cm) FN-DC Field Calibration 0.7" (1.9 cm) A: State of Charge Indicator Lights This section outlines the procedure for calibrating a FLEXnet DC Battery Monitor that has already B: Mounting Screws been installed in a system. C: Hub Cable Port...
  • Page 3: Troubleshooting

    Troubleshooting Installation Installing the FLEXnet DC Common Problems The FLEXnet DC mounts in a ¾" DC circuit breaker slot installed inside an OutBack Power load center. To mount the FLEXnet DC inside an OutBack Power enclosure: Symptom Possible Cause Possible Remedy 1.
  • Page 4: Example Use Cases

    ○ The wires connected to the wiring block should match the color-coded maximum, 100 Vdc minimum) may FLEXmax FLEXmax label where the wiring block inserts into the FLEXnet DC. help protect the devices. Charge Charge ○ The wiring block can accommodate wire sizes from #12 AWG to #26 AWG...
  • Page 5: Shunt Operation

    Current into signal and out of to fan batteries Shunt C NOTES  The FLEXnet DC shunts must be connected to the negative (low) side of whatever device they monitor to avoid damaging Shunt B Inverter Vent Fan the FN-DC.
  • Page 6: Operation

    14.1 and 14.6 Vdc in a 12-volt system (58 to 59 Vdc in a 48-volt The FLEXnet DC must be programmed using an OutBack system , as shown to the right). This setting Power system display such as the MATE3s.
  • Page 7 If the auxiliary relay is not used, skip to Step 8. One of the primary benefi ts of the FLEXnet DC is its ability to accurately monitor a battery bank’s state of charge (SOC). While voltage gives an approximation of SOC, this is only accurate if the battery has stabilized in a resting state for a period of several hours at room temperature.
  • Page 8 When the MATE3s Advanced Generator Start (AGS) function is active and set to control the FN-DC A relay, it will override the set points shown here. For generator control, OutBack most FN-DC data using a web browser. Power strongly recommends using the AGS function rather than the FN-DC set points, as MATE3s Battery Status described in the MATE3s literature.
  • Page 9: Programming The Auxiliary Relay

    FN-DC LED Indicators The FN-DC indicates the battery bank’s SOC with a set The FLEXnet DC provides an auxiliary (A ) relay to activate a DC accessory like a ventilation fan or light. of 5 LED indicators. These are displayed in the breaker The A relay is a "dry contact"...
  • Page 10: Viewing Data

    FN-DC Current into and out of batteries Shunt B Battery Bank Current into and out of Click Battery Charging inverter Devices Status Relay Inverter Click FN-DC Page 10 900-0093-01-00 Rev C Page 11 ©2020 OutBack Power. All Rights Reserved.

Table of Contents