Müller-Elektronik UNI-Control S Installation And User Manual

Advertisement

Installation and User´s Guide
UNI-Control S
January 1995
-----------------
Datei : 302531-02_E(ME011513).DOC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UNI-Control S and is the answer not in the manual?

Questions and answers

Summary of Contents for Müller-Elektronik UNI-Control S

  • Page 1 Installation and User´s Guide UNI-Control S January 1995 ----------------- Datei : 302531-02_E(ME011513).DOC...
  • Page 2: Table Of Contents

    4 Maintenance ....................34 4.1 Computer........................34 4.2 Switch box / machine plug..................34 4.3 Note..........................34 5 Error recovery ....................35 6 Maschine data ....................35 Seite - 2 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 3 Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 3 -...
  • Page 4: Summary

    Machine plug on the UNI-Control S Connects switch box to machine adapter. Machine plug on the switch box or on the machine adapter. Connection to UNI-Control S. Switch box (art. no.: see price list) Operating panel of the attached machines (e.g. field sprayer) with connection to UNI-Control S.
  • Page 5: Description Of The System

    Description of the system The UNI-Control S can be used universally on many agricultural machines as a measuring, controlling and monitoring instrument. It consists of the computer (1), the console (10 - 14) and the tractor signal distributor (16) with the cardan shaft/wheel sensor (20) to establish the distance.
  • Page 6: Machine Programs

    • Universal / Telescope spreader (sewage sludge) • Seed machine The UNI-Control S recognizes from the code on the machine plug (4), which machine is attached at any specific time.The corresponding program and the individual machine data are called up automatically by the UNI-Control S.
  • Page 7: Single Seed Planter

    There are two methods of linking up the UNI-Control S with single seed planters. • Optical sensor (grain checking) With the machine adapter "Einzelkorn“ (art. no.: 302 601) the UNI-Control S can be connected to the optical control devices of the following firms: ACCORD, BECKER; GASPARDO, KLEINE, KONGSKILDE, NODET and SICAM.
  • Page 8: Combine Harvester

    1.3.8 Seed machine The UNI-Control S can be connected to the ACCORD seed machine monitor ESC by means of a machine adapter. A large choice of rhythms is availble for switching the tram lines.
  • Page 9: Fitting Instructions

    1 m. The bracket (13) is attached to the console´s tube. The profil slide (10) is mounted on to the bracket. The UNI-Control S computer (1) is pushed on to the profile from above and secured with the wing-bolt.
  • Page 10: Battery Connection Cable For The Switch Box Or Machine Adapter

    The distance should be 5 - 10 mm. Diagram.: 312 084.83.1 Seite - 10 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 11: Sensor Y (Working Position)

    40 mm away from the magnet switch. Example: Tractor - three-point hydraulics Diagram: 312090.82.1 Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 11 -...
  • Page 12: Tractor Signal Distributor For Tractors With A Signal Socket

    2.4.2 Connnecting machines with machine adapters Securing the machine adapter to the console (10 - 14) is carried out as described in paragraph 2.4.1 (switch box). Seite - 12 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 13: Safety

    Safety 2.5.1 Specified implementation The UNI-Control S is specified only for agricultural use. Use outwith this area is regarded as unspecified. The manufacturer does not accept liability for damages to persons or property resulting from unspecified use. In such cases all risks are the responsibility of the user.
  • Page 14: Operating Instructions

    (A) alphanumerical display = a display showing letters and numbers (B) Softkeys = keys with various functions controlled by the software (program) (C) Cursor = writing mark Seite - 14 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 15: Operating Scheme

    Operating scheme Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 15 -...
  • Page 16: Menu Selection

    (l/ha) are displayed. By pressing the T4 key (next) additional information is displayed, e.g. spray pressure. The order is concluded with the T2 key. Seite - 16 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 17: Operating Procedure

    Connect the maschine to the tractor, connect the switch box or machine plug with the UNI-Control, making sure that it is set in "off" position. Switch on the UNI-Control S, the machine adapter identifies the machine automatically and the corresponding program together with the machine´s specific data are automatically called up.
  • Page 18: Operating Examples

    The orders which have already been \-----------------\-----+ processed are stored here (max. 20). Press the T3 key for the machine data. Press the T4 key for the operation data. Seite - 18 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 19 The T3 key (delete) deletes the machine data of the machine selected. Press the T4 key for menu selection. Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 19 -...
  • Page 20 R a d a r | N e x t |-------------->| calibration test. +-------------------------\-----------------\ | Press the T4 key to proceed to the next \-----------------\-----+ | display Seite - 20 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 21 | I m p u l s e s / l |-------------------------|-----------------|------| | 2 5 9 3 2 5 I m p . |-------------------------|-----------------|------| 5 1 2 . 5 0 +-------------------------\-----------------\ \-----------------\-----+ Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 21 -...
  • Page 22 . the boom section 1 is on the outside |-------------------------|-----------------|------| left. | P a r t w i d t h |-------------------------|-----------------|------| Right: Seite - 22 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 23 Press the T1 key for menu selection. Press the T4 key to proceed to the next display +-------------------------------------+ Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 23 -...
  • Page 24 (e.g.. Tecnoma control chest) \-----------------\-----+ Press the T2 key with a connection to the ball valve control chest from the firm Jacoby. Seite - 24 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 25 Press the T1 key for menu selection. Press the T3 key for the filling of bin / tank. Press the T4 key for operation data. Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 25 -...
  • Page 26 |---> Or Press the T2 key to select the current |-------------------------|-----------------|------| operation data. Press the T3 key to save the recorded +-------------------------\-----------------\ data. \-----------------\-----+ Seite - 26 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 27 N e x t | |---> Ms press either the T1 key or the T3 key. +-------------------------\-----------------\ Press the T4 key for memory 4. \-----------------\-----+ Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 27 -...
  • Page 28 |-------------------------|-----------------|------| Right: 0 . 0 0 B a c k | |---> Press the T4 key to go back to the +-------------------------\-----------------\ program \-----------------\-----+ Seite - 28 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 29 1 / m i n | N e x t | |---> Op Press the T4 key to go back to the +-------------------------\-----------------\ operation data. \-----------------\-----+ Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 29 -...
  • Page 30: Example 2: Program Pneumatic Fertilizer Speader

    I m p .| the left. The impulses determined by |------------------------|------------------|------| actuation of the dosage shaft are 0 , 0 0 counted. +------------------------\------------------\ Seite - 30 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 31 Press the T1 key for the order data |-------------------------|-----------------|------| Press the T4 key to proceed to the next N e x t | |---> Ms display. +-------------------------\-----------------\ \-----------------\-----+ Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 31 -...
  • Page 32: Example 3: Program Tractor

    N o | working position via the tractor plug. |------------------------|------------------|------| | t r a c t N e x t | |---+ +-------------------------\-----------------\ \-----------------\-----+ Seite - 32 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 33 | o w n! |-------------------------|-----------------|------| | C H O P P E R |-------------------------|-----------------|------| 2 9 0 1 / m i n | +-------------------------\-----------------\ \-----------------\-----+ Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 33 -...
  • Page 34: Maintenance

    The boxes should be protected against moisture. If the 48-pin plug is pulled out, it should be covered by the cap provided. Note When welding is being carried out the computer and switch box must be removed from the machine. Seite - 34 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
  • Page 35: Error Recovery

    ____________________ - Impulses/100m (medium soil) ____________________ - Impulses/100 m (firm soil) ____________________ - Working width. ____________________ - Factor impulses/litre ____________________ - Control constants ____________________ Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 35 -...

This manual is also suitable for:

302531

Table of Contents