  • Page 1 Kongsberg K-Sync Synchronizing Unit Product description Kongsberg Maritime 342385/B March 2010...
  • Page 2 Kongsberg Maritime AS. Kongsberg Maritime AS endeavours to ensure that all information in this document is correct and fairly stated, but does not accept liability for any errors or omissions.
  • Page 3: Table Of Contents

    Product description Table of contents SYSTEM OVERVIEW ............5 TRIGGER GROUPS ............. 7 Trigger display......................8 ECHO SOUNDER STATUS ..........10 Enable/disable echo sounder ..................10 DIAGNOSTIC TOOL ............11 TECHNICAL SPECIFICATIONS ......... 12 DRAWINGS ..............13 342385/B...
  • Page 4 Kongsberg K-Sync 342385/B...
  • Page 5: System Overview

    System overview 1 SYSTEM OVERVIEW The Synchronizing Unit schedules the echo sounders to transmit according to trigger groups. There are a total of 16 trigger groups and any number of echo sounders can be assigned to a group (zero or more). Each group is triggered consecutively, while the echo sounders assigned to a group are triggered at the same time.
  • Page 6 Kongsberg K-Sync The Synchronizing Unit controls pinging and receives status from the echo sounders via the signal interface. A trigger output is provided for each echo sounder as well as inputs for receiving feedback signals from echo sounders. Feedback signals are not required, but will be used when available.
  • Page 7: Trigger Groups

    Trigger groups 2 TRIGGER GROUPS The trigger groups are the basis for the scheduling of the echo sounders. The Synchronizing Unit uses the runtime parameters to determine the individual timing of the echo sounders, while the trigger groups specify in what order and which echo sounders will transmit together.
  • Page 8: Trigger Display

    Kongsberg K-Sync Figure 3 Trigger groups Trigger group configuration dialogue allows user to assign echo sounders to trigger groups 2.1 Trigger display The trigger display is a real-time display that shows the current state of each echo sounder plotted across time. There are two...
  • Page 9 Trigger groups Figure 4 OS 38 – Echo sounder This plot shows an echo sounder, OS 38, which has the longest period in the group and consequently determines the overall ping rate for the groups it is assigned to. 342385/B...
  • Page 10: Echo Sounder Status

    Kongsberg K-Sync 3 ECHO SOUNDER STATUS The individual states of the echo sounders are shown in the Echo sounder status display. For each echo sounder there is also a check box for enabling and disabling the system. Figure 5 Echo Sounder Status...
  • Page 11: Diagnostic Tool

    Diagnostic tool 4 DIAGNOSTIC TOOL The diagnostic display shows the signal level on each input and output of the Synchronizing Unit. There are 48 inputs (feedback signals) and 16 outputs (trigger signals). In Fig. Diagnostic Display on page 11, the dialogue for the diagnostic display is shown.
  • Page 12: Technical Specifications

    Kongsberg K-Sync 5 TECHNICAL SPECIFICATIONS Some of the timing and signal specifications with respect to the K–Sync are listed in the table below. Display resolution (horizontal): 50 ms Display width: 10, 30 or 60 seconds Max. trigger groups: Timing resolution of synchronization: 1 ms...
  • Page 13: Drawings

    Drawings 6 DRAWINGS • SSU Rack Unit • Outline Dimensions Cabinet 342385/B...
  • Page 16 © 2009 Kongsberg Maritime Ko n g s b e r g M a r it im e A S t r a n d p r o m e n a d e n 5 0 Te le p h o n e : + 4 7 3 3 0 2 3 8 0 0 P.