yellow jacket 69341 Operation Manual

yellow jacket 69341 Operation Manual

H2 tracer gas leak detector

Advertisement

Quick Links

H
Tracer Gas
2
Leak Detector
Model 69341
Detects 5% H
in 95% Nitrogen Tracer Gas
2
Operations Manual
To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com

Advertisement

Table of Contents
loading

Summary of Contents for yellow jacket 69341

  • Page 1 Tracer Gas Leak Detector Model 69341 Detects 5% H in 95% Nitrogen Tracer Gas Operations Manual To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com...
  • Page 2 INTRODUCTION The YELLOW JACKET H Hand-held Leak Detector features a long life, solid-state heated sensor technology that is designed to detect /Nitrogen Tracer Gas mixture The H Leak Detector does not require rechargeable batteries. When used with the H /Nitrogen Tracer Gas mixture, the H Leak Detector will detect leak rates less than 5 ppm.
  • Page 3: Low Battery Indicator

    Leak Detector Control Panel Low battery indicator Low Battery Sensitivity level indicator Indicator Sensitivity Level Sensitivity adjust Power On/Off Operating Instructions 1. TURN ON: Press the ON/OFF button once to turn on and again to turn off. NOTE: Hold button down for approximately 1 second to turn unit off.
  • Page 4: Troubleshooting

    Low Battery Indicator Replace the 4 AA Alkaline batteries when the red LED on the control panel is lit. Follow battery installation instructions under Maintenance section. Troubleshooting To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com...
  • Page 5: Adjusting Sensitivity Levels

    Adjusting Sensitivity Levels To choose another sensitivity level, press the Sensitivity button. The LED below each level will change indicating the new setting. The Leak Detector will default to the Norm sensitivity level automatically once the unit comes out of the warm up cycle and the green LED will turn on.
  • Page 6: Maintenance

    Maintenance Batteries: Install Batteries: Remove screw located at rear end of unit and flip up the hinged battery door to open as shown. Always insert all four batteries into the battery compartment in the correct direction. Note polarity mark on the inside of the battery door for proper battery orientation (see illustration on page 4).
  • Page 7: Product Specifications

    Product Specifications 69341 Model # Tracer Gas Sensitivity < 5 ppm Sensor Life > 300 hours Response Time Instantaneous Power Supply 4 AA Alkaline batteries Battery Life 6 hours continuous Warm up time < 20 seconds Probe length 17 inches Weight, lbs 1.5 lbs...
  • Page 8: Replacement Parts

    69386 Carrying Case 69343 18 MONTH LIMITED WARRANTY Ritchie Engineering guarantees YELLOW JACKET H Leak Detector to be free of defective material and workmanship that would affect the life of the product under normal use for the purpose for which it was designed. This warranty does not...