WARNING
Read all instructions and warnings before installing or operating
this product - Call 805-549-9724 for additional free copies of this
manual.
IMPORTANT - PLEASE READ
• This installation and operation guide is written to assist in the
installation, operation, and maintenance of the ComAir 20T
product.
• Please read this manual carefully and in its entirety before
proceeding with any installation, operation, or maintenance
procedure associated with this equipment. Failure to follow
these instructions could result in personal injury, damage to the
equipment, or reduced product performance.
• In an ongoing effort to improve reliability and operating
efficiency, ClearWater Tech, LLC may find it necessary to make
changes to its products. Therefore, the information contained
in this manual may not conform in every respect to earlier
versions of ClearWater Tech, LLC systems found in the field. If
you have any questions, please contact the ClearWater Tech,
LLC dealer or the ClearWater Tech, LLC service department.

TABLE OF CONTENTS

SAFETY ..........................................................................................2
THEORY OF OPERATION/PRODUCT DESCRIPTION .........................3
FIGURE 1 - TYPICAL COMAIR 20T INSTALLATION .....................3
INSTRUCTIONS ..............................................................................3
INSTALLATION PROCEDURES ........................................................4
UNPACKING .............................................................................4
ASSEMBLING THE COMAIR 20T ...............................................4
FIGURE 2 - EXTERNAL COMAIR 20T COMPONENTS .................4
CHOOSING AN INSTALLATION LOCATION ................................4
FIGURE 3 - COMAIR 20T INSTALLATION LOCATIONS ...............4
COMAIR 20T INSTALLATION ...........................................................5
FIGURE 4 - HOW TO FLIP THE COVER ORIENTATION ................5
FIGURE 5 - COVER ORIENTATION OPTIONS ..............................5
FIGURE 6 - AIRFLOW SENSITIVITY JUMPER ............................5
FIGURE 7 - SETTING THE COMAIR 20T .....................................6
TABLE 1 - CONTROL BOARD DIP SWITCH SETTINGS ................6
OZONE CONTROLLER ..............................................................7
TABLE 2 - MODE SELECTION GUIDANCE - WITH THE AMBIENT
OZONE CONTROLLER ..............................................................7
TABLE 3 - AMBIENT OZONE CONTROLLER CONNECTIONS ......7
TABLE 4 - DIP SWITCH SETTINGS TO USE AMBIENT OZONE
CONTROLLER..........................................................................7
TABLE 5 - MODE SELECTION GUIDANCE WITH AMBIENT ..........
OZONE CONTROLLER ..............................................................7
OZONE CONTROLLER ..............................................................8
FIGURE 8 - REMOTE DISPLAY ..................................................8
FIGURE 9 - AMBIENT OZONE CONTROLLER .............................8
MAINTENANCE ..............................................................................8
FIGURE 10 - MAIN COMPONENTS .............................................9
TROUBLESHOOTING .................................................................... 10
APPENDIX A - SPECIFICATIONS .................................................... 11
APPENDIX B - PARTS LIST............................................................. 11
APPENDIX C - WARRANTY INFORMATION ..................................... 12
2 • Pentair® ComAir 20T Installation and Operation Guide

SAFETY

This Pentair® ComAir 20T system must be installed by a licensed
professional in accordance with all applicable codes and standards
for the jurisdiction in which it is installed. In addition, all plumbing
attached to or used with the ComAir 20T must be installed by a
licensed, professional plumber.
This section of the manual contains safety warnings
WARNING:
and must be read, understood, and applied during
installation, operation, and maintenance of the
ComAir 20T system. Failure to obey the warnings and
instructions herein may present potential health and
safety hazards resulting in death or serious bodily injury
to personnel and damage to the equipment. The safety
information contained in this manual is intended to be
read thoroughly.
Inspect the ComAir 20T system regularly for cracks or
other damage. Cracks and damage can result in leakage
or rupture failure. If the damage is found, immediately
shut down the system until the damage has been
thoroughly inspected and repaired. Do not continue to
operate the system.
Ozone is a colorless gas with a strong odor. Ozone can
DANGER:
be hazardous and can cause severe respiratory toxicity.
Breathing ozone can damage the lungs and cause
headaches, chest pain, coughing, shortness of breath,
and throat irritation. Higher exposure can cause fluid
buildup in the lungs (pulmonary edema). Ozone can also
worsen chronic respiratory diseases such as asthma
and compromise a person' s ability to fight respiratory
infections. In the event of ozone leakage, move to fresh
air immediately.
Ensure any cleaning, repair, or ozone equipment is
done by qualified, correctly trained personnel.
GROUNDING INSTRUCTIONS: This system must be
WARNING:
grounded. In the event of a malfunction or breakdown,
grounding will reduce electric shock risk by providing
a path of least resistance for electric current. This
system is equipped with a cord having a system-
grounding conductor and a grounding plug. The plug
must be plugged into an appropriate outlet installed
and grounded in accordance with all local codes and
ordinances.
Improper connection of the system-grounding
conductor can result in a risk of electric shock. Check
with a qualified electrician or service representative if
you doubt whether the system is properly grounded. Do
not modify the systems plug; if it does not fit the outlet,
have a proper outlet installed by a qualified technician.
Children should be supervised to ensure that they do
WARNING:
not play with the system.