RAYPAK SERVICE INSTRUCTIONS
PROTÉGÉ SERIES PUMP AND FILTER RPAGP, RPSFP, RPCFP
KIT 018225F, LOCK RING, CLEAR LID AND O-RING
IMPORTANT NOTICE: These instructions are for the use of qualified individuals
specially trained and experienced in the installation and maintenance of this type of
equipment and related system components. Installation and service personnel are re-
quired by some states to be licensed. Persons not qualified shall not attempt to install,
service, or maintain this equipment.
DANGER – SHOCK HAZARD: Make sure electrical power to attached pump and
heaters is disconnected to avoid damage to components, potential serious personal
injury or death.
WARNING: Make sure water & power have been turned OFF before making any re-
pairs or service to the unit.
Scope
These kits provide the parts required to replace the lock
ring assembly and basket for the Protégé Line of pumps
and filters.
Kit 018225F
Components
Lock Ring, Clear Lid, O-ring
KIT 018226F, BASKET
Kit 018226F
Components
Basket
Required Tools
None
Recommended Materials
Any quality generic brand of appropriate lubricant
for application onto O-rings and threads of plastic
parts such as "Water Lube".
018225F
018226F
P/N 241841 Rev 2
Effective: 08-14-2020
Replaces: 1-6-2020

Advertisement

loading

Summary of Contents for Raypak PROTÉGÉ RPAGP

  • Page 1 P/N 241841 Rev 2 Effective: 08-14-2020 Replaces: 1-6-2020 RAYPAK SERVICE INSTRUCTIONS PROTÉGÉ SERIES PUMP AND FILTER RPAGP, RPSFP, RPCFP KIT 018225F, LOCK RING, CLEAR LID AND O-RING KIT 018226F, BASKET IMPORTANT NOTICE: These instructions are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components.
  • Page 2 Replacing Lock Ring, Clear Lid, and Basket 1. Turn off the electrical power at the Pump’s power switch and/or unplug it at the receptacle. 2. Allow the pump motor to cool down before servicing the unit. 3. Close the water valves, if installed, to isolate the pump from the system.
  • Page 3 Figure 6. Figure 6. Silicone Rubber O-Ring 8. Reverse steps 6 to 1 in order to assemble and operate the pump using the new kit parts. Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 1-800-260-2758 Fax (805) 278-5468...

This manual is also suitable for:

Protégé rpsfpProtégé rpcfp