Download Print this page
PROception PROAMP24 Instruction Manual

PROception PROAMP24 Instruction Manual

Advertisement

Quick Links

Related Products:
Setback Amplifiers: 1 & 2-Way FM/DAB/UHF Amplifiers without IR
PROAMP12R: 2-Way Setback Amplifier with IR
PROSAT1EYE: IR Control Eye 'Magic Eye
PROLINK22: Flexible 'I/O Link' RF Modulator for Sky
PROCON01: F Male Twist-On +O-Ring - RG6/100
PROCON02: F Male Twist-On +O-Ring Black - RG6/100
PROCON12: F Male Crimp-On Black - RG6/100
PROCON22: F Male Snap Seal / Compression - RG6/100
Other Ranges of Products & Services from Blake UK, PROception & CappSure...
• TV, Wi-Fi & 4G Aerials
• Brackets & Installation Equipment
• AV TV Wall Mounts
• CappSure Wi-Fi IP Cameras
• Coaxial Connectors & Adaptors
• RF Signal Distribution
• HDMI Signal Distribution
• LTE Filtering Products
• Satellite Mounts
• Bespoke Manufacturing
• UK R&D
EU Declaration of Conformity
Blake UK hereby declares that the radio equipment type PROAMP24, PROAMP24R, PROAMP26,
PROAMP26R, PROAMP28 and PROAMP28R are in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet
address:
www.blake-uk.com/DoC
2 Year Guarantee
This guarantee covers failure of your PROception product resulting from manufacturing defect within a
period of 2 years from the date of supply to the end-user. This guarantee does not cover damage to the
product caused by abuse, tampering, defective installation or natural causes such as lightning discharge.
Repair or attempted repair, other than by the manufacturer, will render this guarantee void. This
guarantee does not affect a consumer's statutory rights.
Performance data given are typical unless otherwise stated. We reserve the right to change
product designs and specifications without prior notice.
Website: www.proception.co.uk
Email: support@proception.co.uk
©Blake-UK 2018 All rights reserved E&OE Product Specification may be Changed without Prior Notice
Link to Website:
www.blake-uk.com/amp
www.blake-uk.com/ampr
www.blake-uk.com/eye
www.blake-uk.com/prolink22
www.blake-uk.com/procon01
www.blake-uk.com/procon02
www.blake-uk.com/procon12
www.blake-uk.com/procon22
www.blake-uk.com/aerials
www.blake-uk.com/bracketspoles
www.blake-uk.com/tvbrackets
www.blake-uk.com/cappsure
www.blake-uk.com/procon
www.blake-uk.com/rfsignal
www.blake-uk.com/hdmi
www.blake-uk.com/lte
www.blake-uk.com/satmount
www.blake-uk.com/bespoke
www.blake-uk.com/researchdevelop
VHF/UHF Distribution Amplifiers Instruction Manual
PROAMP24-26-28
www.blake-uk.com/distamp
PROAMP24R-26R-28R
These amplifiers are ideal for use in small digital and analogue reception and distribution systems. All
MK3 products feature a filtered dual-band VHF input which accepts signals in both Bands II and III,
allowing use for Band III DAB or TV, as well as for FM radio.
All these amplifiers are compliant with the Radio Equipment Directive 2014/53/EU and meet the
harmonised standard EN 303 354 for Class 0. As such they work on ALL current UK DTT channels
including channel 60, are resilient to interference and overloading, and cope with multiple carriers. In
cases of strong LTE interference a separate 4G filter should be fitted. These are supplied free by at800,
or higher performance models can be purchased from www.blake-uk.com. (To pass channels up to and
including channel 59 use proLTE1/59, or if channels 58 and 59 are not required, use proLTE1/57).
Features: (Whole Range)
Separate VHF and UHF inputs.
New dual-band VHF input for Band II FM radio and Band III DAB or TV.
4-, 6- and 8-way versions available.
Low noise figure and high output capability.
New equipotential bonding terminal added on Mk 3 versions.
Channels 61-68 can be used for locally modulated signals.
Features: (PROAMP24, 26 & 28)
Traditional multi-way aerial signal amplifiers.
Line power available at UHF input 12V at up to 100 mA.
Higher-gain FULL output on 6- and 8-way versions allows expansion beyond eight points.
IEC connectors.
Features: (PROAMP24R, 26R & 28R)
7 MHz return path for Sky* infrared remote control systems.
Built-in power for IR eyes on all outputs.
F connectors.
Note: R versions do not have input line-power capability or FULL outputs.
Fixing:
Fix the amplifier to a sound vertical surface such as a wall, skirting board or equipment mounting board.
Ventilation gaps of at least 50 mm should be left around the front and sides of the unit. More clearance
will be required below the unit to allow access for the signal cables.
Being fully screened, the amplifier will not be affected by proximity to an antenna. However clearance
of not less than 300 mm from the nearest part of the antenna should be observed to avoid degrading
the antenna's performance. Manufacturer's instructions regarding routing of the cable from the
antenna terminal box must be followed if provided.
Do not leave the amplifier resting on a carpet or install it where it may become smothered with curtains
or other soft furnishing fabrics. When installing the amplifier unit in a roof space ensure that it will not
come into contact with thermal insulation material.
Signal Connections:
To preserve RF screening integrity the signal connections to the amplifier should be made using good
quality coaxial cable and connectors. This is particularly important with digital terrestrial TV (DTT) to
minimise the ingress of impulsive electrical interference from home appliances.
The use of cable benchmarked under the CAI scheme is recommended.
Amplifiers PROAMP24, '26 and '28 require IEC connectors (IEC 60169-2).
Amplifiers PROAMP24R, '26R and '28R requires Type-F connectors (IEC 60169-24).
4
www.blake-uk.com/ampr
1

Advertisement

loading

Summary of Contents for PROception PROAMP24

  • Page 1 300 mm from the nearest part of the antenna should be observed to avoid degrading This guarantee covers failure of your PROception product resulting from manufacturing defect within a the antenna's performance. Manufacturer's instructions regarding routing of the cable from the period of 2 years from the date of supply to the end-user.
  • Page 2 Changing the plug: to be connected a separate diplexer such as the PROception proCOM31T should be used (see example in If the fitted mains plug is not suitable for the socket-outlets in use, it should be cut off and a new plug fitted.

This manual is also suitable for:

Proamp26Proamp28Proamp24rProamp26rProamp28r