Page 3
FGDF7105*1H, FGDF7105*2H Note: When installing replacement bubbler, tighten nut (Item 12) only to hold parts snug in position. Do not over tighten. FIG. 3 Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, remove Items 1 & 2 and adjust screw on Item 4. Clockwise adjustment will raise stream and counter-clockwise adjustment will lower stream.
Page 4
FGDF7105*1H, FGDF7105*2H PARTS LIST 115V PARTS LIST 230V-50/60Hz ITEM NO. PART NO. DESCRIPTION ITEM NO. PART NO. DESCRIPTION 40089C Cover 36232C Relay 40048C Button 31505C Power Cord Regulator Retaining Nut 15005C 31395C Fan Motor 61313C Regulator 66763C Heat Exchanger 40169C Hex Nut 36243C Compressor Serv Pak...