Redback Q 2004 Operating Manual

Impedance meter

Advertisement

Quick Links

1.0 FEATURES:
• Suitable for 50V, 70V and 100V line speaker systems up
to 5kW
• Also suitable for measuring low Impedance speaker loads
of 4 -16Ω
• OLED display shows Impedance and Wattage of the load
• 1Ω to 20KΩ test range
• Auto ranging
• Display accuracy +/-10%
2.0 INTRODUCTION:
The Redback Impedance Meter is an absolute necessity for all PA system installers. An impedance meter is critical for
accurately measuring low impedance loudspeaker systems, incorporating multiple speakers and crossovers, and for measuring
commercial 70V or 100V line speaker systems, which may include many speakers with line transformers and several hundred
meters of cable. Trying to measure this type of load is virtually impossible with a standard multimeter.
The Redback® Q 2004 measures and calculates loads for both 100V and 70V line systems up to 5k Watts in power. Most
impedance meters on the market display the impedance in ohms, leaving the installer to calculate the system wattage. This
impedance meter for 'dummies' designed and manufactured by Redback calculates and displays speaker loads in watts.
Measuring a transformer with a regular ohm meter or multimeter is very difficult and provides inaccurate results. This is
because an ohm meter or multimeter uses DC to measure the resistance. Consider a transformer, which is basically a coil of
wire, the DC resistance will be fairly low. If an AC signal is passed through the winding, the impedance will be much higher,
unless the winding is shorted. In this case the reading will be very low.
In the case of a short circuit the inductance of the transformer tries to impede the current flow through the winding. The
nature of transformers will result in the impedance being reflected into other windings on the transformer being tested. This
means a shorted turn on any winding will show up on the other windings.
For example a short circuit on several hundred metres of cable will not show up as a short circuit on a standard multimeter.
You will actually measure the DC resistance of the cable which will be around 22 ohms for 500 meters of 24/0.2 cable.
Using an impedance meter, measuring the AC resistance will read a short circuit. A short circuit located remotely in a speaker
line is the major cause for amplifiers overheating and blowing DC fuses.
Shorted turns on mains transformers primary windings can also be measured with this meter. If this meter displays a value
of less than 100 ohms, this will indicate that the transformer has a shorted turn.
www.redbackaudio.com.au
Redback® Q 2004 Impedance Meter
Operating Manual
• Push button operation
• System Check Mode (20, 60 or unlimited minutes)
• 5V Rechargeable Lithium Polymer internal battery
• Low battery indication
• Buzzer and Haptic feedback option via Menu access
• USB Charging lead supplied
• Silicon Test Leads supplied
• Soft Carry Case Included
• Rugged yet easy to hold compact hand held case
Q 2004
Impedance Meter
User manual revision number: 1.0 03/12/2020
Redback® Proudly Made In Australia
1

Advertisement

loading

Summary of Contents for Redback Q 2004

  • Page 1 Trying to measure this type of load is virtually impossible with a standard multimeter. The Redback® Q 2004 measures and calculates loads for both 100V and 70V line systems up to 5k Watts in power. Most impedance meters on the market display the impedance in ohms, leaving the installer to calculate the system wattage. This impedance meter for ‘dummies’...
  • Page 2 OFF and ON options and then press the “TEST” button to select. VOLTS: The Redback® Q 2004 impedance meter is suitable for 50V, 70V and 100V systems. Before measuring the impedance of a line, the voltage needs to be set via the Menu button to suit the system application.
  • Page 3 SWITCHING OFF To switch off the Q 2004 all you need to do is press the “TEST” button again. The LCD will display “POWER OFF” for a short time then the unit will power down. The Q 2004 is also equipped with an auto power off function. The unit will automatically power down after a period of 20 seconds in Single test mode and 30 minutes in System check mode, saving precious battery life.
  • Page 4 Redback® Q 2004 Impedance Meter 4.0 IMPORTANT GUIDELINES: Don’t connect the meter to a line that has an amplifier attached to it. The impedance of the output transformer of an amplifier is extremely low and you could be easily be looking for a non-existing short.