Sulzer ABS PC 242 User Manual

Sulzer ABS PC 242 User Manual

Up to 1 o 2 pumps control panel

Advertisement

Sulzer Pumps Wastewater Spain, S.A.
Avda. de la Técnica, 5
28522 Rivas Vaciamadrid (Madrid)
www.sulzer.com
ABS APC
1
2
C
UP TO
Ó
PUMPS
ONTROL PANEL
S
P
W
S
, S. A.
BY
ULZER
UMPS
ASTEWATER
PAIN
U
SER GUIDE
CIF: ES A-28388023 Sociedad Unipersonal inscrita en el Registro Mercantil de Madrid

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ABS PC 242 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sulzer ABS PC 242

  • Page 1 Sulzer Pumps Wastewater Spain, S.A. Avda. de la Técnica, 5 28522 Rivas Vaciamadrid (Madrid) www.sulzer.com ABS APC UP TO Ó PUMPS ONTROL PANEL , S. A. ULZER UMPS ASTEWATER PAIN SER GUIDE CIF: ES A-28388023 Sociedad Unipersonal inscrita en el Registro Mercantil de Madrid...
  • Page 2: Table Of Contents

    4.3 USER GUIDES fOR DEVICES RELATED TO APC CONTROL PANELS LEVEL SENSORS MD124 / MD126 / MD127: USER AND INSTALLATION GUIDE PC242 PUMPS CONTROLLER INSTALLATION GUIDE PC242 PUMPS CONTROLLER USER GUIDE PC242 PUMPS CONTROLLER COMLI/MODBUS REGISTER GUIDE DECLARATION CONFORMITY CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 3: General Description

    To avoid loosing the guaranty, only Sulzer Pumps Wastewater specialist technicians can manage and modify the control panel or, at least have to support any of this kind of works. Contact to Sulzer Pumps Wastewater Spain if you need support (+34 916 702 851).
  • Page 4: Scope. Devices And Features (Enclosure And Power Equipments)

    2.4. SCOPE. DEVICES AND FEATURES (CONTROL CIRCUITS AND EQUIPMENTS Advanced control system with graphic display ABS PC 242, door mounted to allow an easy setting up and use of the system. Ready to work with analogue sensors (0-20 or 4-20mA) or floats. Normally you will receive an offer of an APC version that includes devices for level measurement or level floats (as required).
  • Page 5: Installation Recommendations

    APC control panel with MD 124 pneumatic sensor, replace this T racor and connect directly the racor included in the supply (only when less than 10 m pipe). CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 6 Settings in PC 242 when it is mounted in an ABS APC control panel include a time filter for this input signal, if were needed you could increase the default pre-set time filter setting. CONTROL PANEL SULZER APC 1/2B USER GUIDE...
  • Page 7: Control System Description

    (semiautomatic). Don’t forget also to disconnect and to block the MCB before any maintenance actuation, avoiding taking mechanical or electrical risks (a contactor could have a shortcut, a VFD or a soft starter could present electrical current leakages, etc...). CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 8 Anyway, if the pump mode of operation selector is not in AUTO mode, the semi-auto system will not work with this pump. For safety reasons, the semi-auto system will never work with a pump which mode of operation selector was set to 0. CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 9: Operation

    Página 9 de 19 OPERATION The work of any Sulzer Pumps Wastewater Spain control panel pursues the best pump pit station operation and reliability with lowest energy and maintenance costs. Other designs aspects pursue avoid labour and equipment accidents, not allowing manual operation if the operator doesn’t keep in front of the panel, allowing the complete disconnection of the control panel from outside, etc.
  • Page 10 + / - random band said. The feature is only available to work with analogue level sensor, not buoys, and is useful for preventing the formation of crust (and the resulting odours) regrowth on the walls of the well at elevation where the first bomb usually tear. CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 11 4. Humidity module DI and where would rank synoptic selector mode (manual, automatic or off), and signalling pilots shaker states: thermal and moisture probes, motor protection circuit breaker and motor running. CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 12: Safety Factors

    For safety is done automatically reset all alarms reset brought forward in PC 242 when activating the alarm float. CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 13 "Bn pump oil leaks" also marked by floating contact general fault. IF THE PUMP IS NOT PROBE HUMIDITY, LEAVE WITHOUT CONNECTING TERMINALS FOR SUCH ITEM PICTURE. CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 14 APC box, so this should be set to alarm activated before the trigger point at which the circuit breaker is set. CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 15 In pictures APC basic finish, PC242 is programmed to control the pumps with the buoy signal to sensor failure alarm, so the semiautomatic control system only works with component failure and also against controller failure. CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 16 For APCs with soft starters, you can also use a float stop for semi-automated system that allows you to bring more hysteresis between starting and stopping the system. CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 17 (acoustic / light, picture, etc..) Indicate an alarm both as a power failure or breakdown in PC242 (for would contact their state of rest: NC). CONTROL PANEL SULZER APC 1/2B USER GUIDE...
  • Page 18: Recommended Documents For Reading

    USER GUIDES FOR DEVICES RELATED TO APC CONTROL PANELS LEVEL SENSORS MD124 / MD126 / MD127: USER AND INSTALLATION GUIDE PC242 PUMP CONTROLLER INSTALLATION GUIDE PC242 PUMP CONTROLLER USER GUIDE PC242 PUMP CONTROLLER COMLI/MODBUS REGISTER GUIDE CONTROL PANEL SULZER APC 1/2B USER GUIDE Rev.13 (2018/08/30)
  • Page 19: Declaration Conformity

    Página 19 de 19 DECLARATION CONFORMITY Sulzer Pumps Wastewater Spain, S.A. Declare under our sole responsibility that the products: C.Eléctrico APC 2B / APC 2B Control panel, with references: 84004263/84004264/84004265/84004266/84004307 84004308/84004511/84004512/84004513/84004514 84004515/84004516/84004517/84004518/84004519 84004520/84004521/84004522/84004523/84004524 To which this declaration relates are in conformity with the following standards or other normative...

This manual is also suitable for:

Abs apc 1/2b ng

Table of Contents