CLIMIA CTK 190 Operating Manual

CLIMIA CTK 190 Operating Manual

Mobile air dehumidifier

Advertisement

Quick Links

CLIMIA
CTK 190 mobile air dehumidifier
Operating manual
Edition 2.0
english
Bedienungs-
anleitung
deutsch
Instrucciones
de operación
español
Manuel
d'utilisation
français
Manuale
d'uso
italiano
Gebruiks-
handleiding
nederlands

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CTK 190 and is the answer not in the manual?

Questions and answers

Summary of Contents for CLIMIA CTK 190

  • Page 1 CLIMIA CTK 190 mobile air dehumidifier Operating manual Edition 2.0 english Bedienungs- anleitung deutsch Instrucciones de operación español Manuel d‘utilisation français Manuale d‘uso italiano Gebruiks- handleiding nederlands...
  • Page 3: Table Of Contents

    Content 1.0 Safety information 4-10 2.0 Environmental protection and recycling 3.0 Guarantee 4.0 Intended use 5.0 Transportation and packaging 6.0 Air dehumidification 12-14 7.0 Unit description 8.0 Set-up 9.0 Electrical wiring 10.0 Electrical wiring diagram 11.0 Commissioning 18-20 12.0 Shutdown 13.0 Unit transport 14.0 Care and maintenance 22-23...
  • Page 4: Safety Information

    CLIMIA 1.0 Safety information General safety notes • The air filter must be cleaned • The unit can be used by children at intervals of no more than 2 8 years and up and by persons Carefully read the operating manual weeks.
  • Page 5 CTK 190 mobile air dehumidifier Additional safety notes when • The air-inlet grille must always • The accumulation of refrigerant be kept free of dirt and loose handling refrigerant R290 due to leakages can lead to a objects. fire and explosions in rooms which are too small due to the •...
  • Page 6 CLIMIA Safety instructions for the • The unit must be transported • Do not leave the units running operator upright. Residue from the for an extended period condensate must be drained off unsupervised. The operational safety of the units before transport. The unit must...
  • Page 7 CTK 190 mobile air dehumidifier Do not allow children to play with Never cover the air inlets and Do not stand or sit on the unit. the unit outlets. Unplug the power plug when not in Unplug the power plug before Ensure the voltage is correct use for a long period.
  • Page 8 CLIMIA Safety instructions for certified • Provide fire extinguishers The following safety checks specialist personnel Provide appropriate fire must be carried out when using extinguishers before starting combustible refrigerants: • Check the work area work. For this purpose, dry - The fill level adjusts to the size...
  • Page 9 CTK 190 mobile air dehumidifier • Repairs to closed components • Wiring • Leak detection methods Before repairing closed Lines must be checked for the The following leak detection components/housing parts, the following damage: methods are permitted for unit must be free from voltage.
  • Page 10 CLIMIA • Leak detection methods Stick to the following procedure: after filling The following leak detection 1. Drain the refrigerant - Never exceed the maximum methods are permitted for 2. Flush the system with insert fill level. The system must be...
  • Page 11: Environmental Protection And Recycling

    Make a valuable return the "certificate of warranty" The units must not be used for any contribution to reducing waste to Climia Intakt GmbH at the time other purpose. and sustaining raw materials. Only when the units are purchased and dispose of packaging at approved commissioned.
  • Page 12: Air Dehumidification

    The mechanical heat that is released by the dehumidification Using process is fed back into the room. Climia air dehumidifiers Under normal use, the • Even if windows and doors are well insulated, water and air dehumidifier uses...
  • Page 13 CTK 190 mobile air dehumidifier Water vapour condensation Temp. Water vapour content in g/m at humidity of °C 100% Because the capacity for the maximum possible volume of water vapour increases as the air is 10.2 12.8 heated, the volume of water vapour 10.4...
  • Page 14 CLIMIA Condensation heat The amount of energy from With drying operations, a heat evaporation heat and condensation cycle is created, whereby heat The energy transferred to the air heat is the same. is consumed for evaporation from the condenser consists of: and released for condensation.
  • Page 15: Unit Description

    CTK 190 mobile air dehumidifier 7.0 Unit description The units have been designed for Operating sequence temperature and the relative universal and straightforward air humidity, condensed water will The units are switched on and off dehumidification. drip into the condensate trap by the power key.
  • Page 16: Set-Up

    CLIMIA 8.0 Set-up For the best economic and safe use • The room being dried or of the units, the following notes dehumidified must be closed to must be followed in full: the surrounding atmosphere • The units must be set up in an •...
  • Page 17: Electrical Wiring

    CTK 190 mobile air dehumidifier 9. 0 Electrical wiring • The units are operated with NOTE CAUTION! 230V / 50Hz alternating The electrical connection to the All cable extensions must only be current units must be made at feed- used in fully unreeled or reeled points with residual current off condition.
  • Page 18: Commissioning

    CLIMIA 11.0 Commissioning Before commissioning the unit or if 2. Open the air flap on the top of NOTE local requirements dictate, the air- the unit. In room temperatures below inlet grill and air-outlet grill must 10°C and relative humidity be checked for contamination.
  • Page 19 CTK 190 mobile air dehumidifier Adjusting units/moisture Adjusting the discharge Automatic defrost system direction The unit’s dehumidification power The moisture contained in the is entirely dependent on the The dehumidified room air is room air condenses when cooling conditions inside the room, the discharged on the top of the unit.
  • Page 20 CLIMIA Emptying the condensate Continuous operation with Leakage control device container external condensate outlet The unit is equipped with a The integrated condensate The units are equipped with a leakage control device to prevent container must be emptied from special connection nozzle on the damage in the event of refrigerant time to time.
  • Page 21: Shutdown

    CTK 190 mobile air dehumidifier 12.0 Shutdown 13.0 Unit transport • Use the POWER key to switch the The units are equipped with four If residual moisture remains on unit off. foot rollers and an additional the evaporator or water remains...
  • Page 22: Care And Maintenance

    CLIMIA 14.0 Care and maintenance • Observe the regular care and Cleaning the condenser and NOTE maintenance intervals evaporator Regular care and maintenance is fundamental to a long service • In accordance with the operat- The unit housing must be opened...
  • Page 23: Troubleshooting And Customer Service

    CTK 190 mobile air dehumidifier 15.0 Troubleshooting Filter cleaning The units are manufactured using state-of-the-art production To prevent damage to the unit, it is 5. Clean the air filter with methods and tested several times equipped with an intake grill with lukewarm water or a vacuum to verify their correct function.
  • Page 24 CLIMIA The unit runs but condensate The unit is loud or condensate CAUTION! is not formed: runs out: Work on the refrigerant system and on the electrical equipment • Check the room temperature. • Check whether the unit is on a...
  • Page 25 CTK 190 mobile air dehumidifier...
  • Page 26: Unit Illustration

    CLIMIA 16.0 Unit illustration We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
  • Page 27: Spare Parts List

    CTK 190 mobile air dehumidifier 17.0 Spare parts list Designation Base plate Conveyor rollers Compressor, cpl. Vibration dampers Suction pipe High pressure distribution Centre wall Condenser (compressor) Microswitch Condensate trap Fin vaporiser Fin condenser Capillary Support plate Fan motor Fan housing...
  • Page 28: Maintenance Log

    CLIMIA ✍ 18.0 Maintenance log Unit type: ........Unit number: ........10 11 12 13 14 15 16 17 18 19 20 Unit cleaned - outside - Unit cleaned - inside - Fan blade cleaned Fan housing cleaned Condenser cleaned...
  • Page 29: Technical Data

    CTK 190 mobile air dehumidifier Technical data Series CTK 190 Operating range, temperature °C 6 to 32 Operating range, humidity % RH 40 to 100 Dehumidification capacity max. l/day At 30 °C/80 % RH l/day At 20 °C/70 % RH l/day At 15 °C/60 % RH...
  • Page 30: Ec Declaration Of Conformity

    We hereby declare that the units named below, as produced and sold by us, satisfy the relevant basic requirements of the EC directives, EC safety standards and product-specific EC standards. Intakt GmbH Name of Manufacturer: Climia - Klima- und Wärmetechnik Niemeierstraße 13 D - 32758 Detmold Name of the CE representative: Intakt GmbH Climia - Klima- und Wärmetechnik...
  • Page 31 CTK 190 mobile air dehumidifier...
  • Page 32 Intakt GmbH Climia - Klima- und Wärmetechnik Niemeierstraße 13 D - 32758 Detmold...