You will also find instructions on installing, configuration and testing. This guide is for anyone involved with the design, maintenance and purchasing of a Crisis EVC system. It is assumed that anyone using this product has the knowledge and appropriate certification from local fire and electrical authorities.
Unpacking............................10 Installation ............................11 Connection via an Crisis EVC Panel .................... 11 5.2 Connection via an Crisis Type B Outstation ................11 System Operation ..........................12 Raising the Alarm Inside the WC ....................12 6.2 Indication Outside the WC ......................12 6.3 Acknowledging the Alarm ......................
Product Overview The Crisis Assist Call WC Kit is a 2 wire system consisting of a ceiling pull cord located near to the WC, cancel plate also located near to the WC and over door indicator plate located above the door outside of the WC.
Crisis Assist Call WC Kit Installation & User Guide Design Guidelines Before designing an emergency assistance alarm the guidelines in BS8300:2009 and “Building Regulations Approved document M:2010” should be consulted first. 1000mm 800mm - 900mm 100mm Level with Toilet Front...
Crisis Assist Call WC Kit Installation & User Guide Important Safety Information This Equipment must only be installed and maintained by a suitably skilled and competent person. This Equipment is defined as Class 2 in EN60950 (Low Voltage Directive) and must be EARTHED.
Crisis Assist Call WC Kit Installation & User Guide Installation The Crisis Assist Call WC device plates mount onto a 25mm UK single gang back box. Connection via an Crisis EVC Panel The devices are wired to the terminals marked 0 and +, the devices are polarity sensitive, however there are no in or out terminals and devices can be wired in any order.
Figure 4: Crisis Assist Call WC Kit Wiring from Type B Outstation There is the facility to connect a Crisis Assist Call WC Kit to a Type B Outstation however please see below as the wiring details are different from those previously mentioned.
6.4 Resound Feature If the Crisis Assist Call alarm is not reset within 2 minutes of being acknowledged it will automatically resound causing the master station and all of the devices within the alarm circuit to flash and sound mentioned above.