Manual Index INSTALLATION AND OPERATION MANUAL Pressurized Lubrication System P/N: 104300 IMPORTANT! Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems reserves the right to change product without prior written notifi...
(fl ammable, caustic, etc.) unless the pump is specifi cally designed and designated to handle them. Other brand and product names are trademarks or registered trademarks of their respective holders. ®Burks is a registered trademark of Crane Pumps & Systems, Inc. 2003, 1/2006, 9/06, 3/07 Alteration Rights Reserved...
Page 3
These instructions are intended as a guide to good installation practice. A correct installation, combined with regularly scheduled maintenance will generally insure a longer and more trouble-free pump service life. The tables below are for your convenience in maintaining these records. PUMP INSTALLATION AND PERFORMANCE RECORD Pump Catalog No.__________________________ Discharge Gauge, Reading _______________ Head Feet...
Lubrication: Next install item (44) and item (6) pipe nipple shut off valve No lubrication is required for the liquid end of any BURKS combination (Figure “A” Pos. 3) on the other side. Install turbine pump. Motors are equipped with ball bearings piping to connect supply water (Figure “A”...
Page 6
Adding Boiler Compound: Motor: BOILER COMPOUND SHOULD NOT BE INTRODUCED Keep motor clean and dry. It is drip-proof when installed INTO SYSTEM ON THE SUCTION SIDE OF PUMP. Boiler horizontally and the windings are protected from excess compound often coagulates when it contacts hot water humidity, but extreme conditions should be avoided when and becomes abrasive, and will damage the race way and possible.
Page 7
LIFE-LOK® External Impeller Adjustment is a patented feature found exclusively on BURKS Turbine Pumps. It allows for precise setting of pump performance during production testing. Every BURKS Turbine Pump is factory tested for optimum performance, and the impeller position is locked in. Any further adjustment of a new pump is not required or recommended.
PARTS LIST ITEM QTY. PART NO. DESCRIPTION 104303 Base Assembly Steel 104308 Pipe Nipple .75” NPT x 6.00” Lg., Galv. 104320 Straight Elbow 45°, .75” NPT, Galv. 061956 Close Nipple 1.25” NPT, Galv. 104311 Pipe Nipple 1.00” NPT x 3.375” Lg., Galv. 105659 Ball Valve .25”...
Page 10
Limited 24 Month Warranty Crane Pumps & Systems warrants that products of our manufacture will be free of defects in material and workmanship under normal use and service for twenty-four (24) months after manufacture date, when installed and maintained in accordance with our instructions.This warranty gives you specifi c legal rights, and there may also be other rights which vary from state to state.
Page 11
IMPORTANT! WARRANTY REGISTRATION Your product is covered by the enclosed Warranty. To complete the Warranty Registration Form go to: http://www.cranepumps.com/ProductRegistration/ If you have a claim under the provision of the warranty, contact your local Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”.