Download Print this page
Leb Electronics L0428R Instruction Manual

Leb Electronics L0428R Instruction Manual

Secret key system

Advertisement

Quick Links

INSTRUCTIONS MANUAL
SECRET KEY SYSTEM
SECRET KEY SYSTEM
1

Advertisement

loading

Summary of Contents for Leb Electronics L0428R

  • Page 1 INSTRUCTIONS MANUAL SECRET KEY SYSTEM SECRET KEY SYSTEM...
  • Page 2 ENGLISH SECRET KEY SYSTEM The manufacturer reserves the right to modify or improve the product without prior notice. Any inaccuracies or errors found in this manual will be corrected in the next edition. Man. Vers 25.03.2014...
  • Page 3 Secret Key System works only with Leb electronics receiver RSK4/RPSK4  It is possible to verify codes of transmitters (installation code and Tx code) only with the original L0428R programmer that was used to program transmitter. No other L0428R than the original one can do it.
  • Page 4 ENGLISH...
  • Page 5: Preliminary Operations

    Turning on the programmer To turn on the programmer, press the following key: The display will show "0428R Analyzer SECRET KEY" and programmer is ready to program Leb electronics remotes in SECRET KEY mode. To switch to programming in FIXED CODE mode, press F2. Display will show “0428R Analyzer FIXED CODE MODE”.
  • Page 6 ENGLISH Operations Attention: In order to avoid undesired signals, the operating range has been reduced to 1 m of distance. The programmer operations consist of 4 menus. SECRET KEY MODE To codify transmitters in order to store them manually into receiver of MANUAL Menu 1 a selected installation.
  • Page 7: Installation

    ENGLISH MANUAL Menu 1 - Description STORING  To codify a transmitter in order to insert it manually in the receiver of a selected installation. SECRET KEY MODE Insert unique installation code (from 1 to 4095) assigned 1 - 1 INSTALLATION Press key to the specific installation..
  • Page 8 ENGLISH REMOTE AUTO Menu 2 - Description STORING SECRET KEY MODE  To codify a transmitter in order to insert it automatically (just with a simple push on the remote) into an installation This function will be used when you must insert a new code in the receiver without a manual action on it. Insert unique installation code (from 1 to 4095) assigned 2 - 1 INSTALLATION...
  • Page 9 ENGLISH REMOTE CODE Menu 3 - Description REPLACING SECRET KEY MODE  To codify a transmitter in order to replace (and cancel) an already stored transmitter code. REPLACING BY KNOWING THE CODE OF REMOTE TO BE REPLACED Insert unique installation code (from 1 to 4095) assigned 3 - 1 INSTALLATION Press key...
  • Page 10 ENGLISH REMOTE CODE Menu 3 - Description REPLACING SECRET KEY MODE  To codify a transmitter in order to replace (and cancel) an already stored transmitter code. REPLACING BY KOWING THE POSITION IN THE RECEIVER OF REMOTE TO BE REPLACED Insert unique installation code (from 1 to 4095) assigned 3 - 1 INSTALLATION...
  • Page 11 ENGLISH SETTING Menu 4 - Description  Manual POWER OFF: To turn on or turn off the programmer, you must press  Automatic POWER OFF: After 3 minutes of non operation, programmer will switch off.  Automatic BACKLIGHT: When you press any key, the display backlight goes on for 15 seconds. ...
  • Page 12  Switch on programmer and wait for display to show “Analyzer L0428R SECRET KEY”  While the display shows “Analyzer L0428R SECRET KEY” press key of SMARTY TPW4/TPK4 transmitter to check and verify that following message is displayed: RECEIVED! INST=73...
  • Page 13 ENGLISH Operations (in Fixed Code mode) After switching on the programmer, press F2 Key to select FIXED CODE. “Analyzer 0428R FIXED CODE MODE” Attention: In order to avoid undesired signals, the operating range has been reduced to 1 m of distance. The programmer operations consist of 3 menus: FIXED CODE MODE INCREMENTAL...
  • Page 14 ENGLISH INCREMENTAL Menù 1 - Description TX CODE FIXED CODE MODE Enter a remote control code (from 1 to 1023) at your 1 - 1 CODE TX Press key choice. Installation code 854 has been selected in the example. Select the transmission standard by means of the keys  1 - 2 STANDARD 1 Press key and ...
  • Page 15 ENGLISH STATIC Menù 2 - Description TX CODE FIXED CODE MODE Enter a remote control code (from 1 to 1023) at your 1 - 1 CODE TX Press key choice. Installation code 277 has been selected in the example. Select the transmission standard by means of the keys  1 - 2 STANDARD 1 Press key and ...
  • Page 16 ENGLISH SETTING Menu 3 - Description  Manual POWER OFF: To turn on or turn off the programmer, you must press  Automatic POWER OFF: After 3 minutes of non operation, programmer will switch off.  Automatic BACKLIGHT: When you press any key, the display backlight goes on for 15 seconds. ...
  • Page 17 Switch on programmer, press F2 Key to select FIXED CODE. “Analyzer L0428R FIXED CODE MODE”  While display shows “Analyzer L0428R FIXED CODE MODE” press key of SMARTY TPW4/TPK4 or TSAW4N transmitter to check and verify that following message is displayed:...
  • Page 18 Switch on programmer, press F2 Key to select FIXED CODE. “Analyzer L0428R FIXED CODE MODE”  While display shows “Analyzer L0428R FIXED CODE MODE” press key of transmitter to be copied and verify that following message is displayed: 11 12...
  • Page 19 ENGLISH NOTES...