Kenwood TK-8180H Service Manual page 63

Hide thumbs Also See for TK-8180H:
Table of Contents

Advertisement

TK-8180H/8182H
Item
Condition
11. Max DEV
1) Adj item : [DEV_ _]
adjust
Adjust : [✳✳✳.]
AG : 1kHz/50mV at MIC terminal
Deviation meter filter
LPF : 15kHz
HPF : OFF
2) Adj item : [D.EV_ _] →
• Narrow
[D.E.V._ _] → [D.E.V._._.]
Adjust : [✳✳✳.]
PTT : ON
• Wide
3) Adj item : [DEV_ _]
Adjust : [✳✳✳]
PTT : ON
12. MIC
[Panel test mode]
sensitivity
1) CH-Sig : 1-1
check
AG : 1kHz/5mV at MIC terminal
(Wide only)
PTT : ON
13. QT deviation 1) Adj item : [QT_ _ _]
adjust
Adjust : [✳✳✳.]
Deviation meter filter
LPF : 3kHz
HPF : OFF
2) Adj item : [Q.T_ _ _] →
• Narrow
[Q.T._._ _] → [Q.T._._._.]
Adjust : [✳✳✳.]
PTT : ON
• Wide
3) Adj item : [QT_ _ _]
Adjust : [✳✳✳]
PTT : ON
14. DQT
1) Adj item : [DQT_ _]
deviation
Adjust : [✳✳✳.]
adjust
Deviation meter filter
LPF : 3kHz
HPF : OFF
2) Adj item : [D.QT_ _] →
• Narrow
[D.Q.T._ _] → [D.Q.T._._.]
Adjust : [✳✳✳.]
PTT : ON
• Wide
3) Adj item : [DQT_ _]
Adjust : [✳✳✳]
PTT : ON
15. LTR
1) Adj item : [LTR_ _]
deviation
Adjust : [✳✳✳.]
adjust
Deviation meter filter
LPF : 3kHz
HPF : OFF
2) Adj item : [L.TR_ _] →
• Narrow
[L.T.R._ _] → [L.T.R._._.]
Adjust : [✳✳✳.]
PTT : ON
• Wide
3) Adj item : [LTR_ _]
Adjust : [✳✳✳]
PTT : ON
62
ADJUSTMENT (TK-8182H)
Measurement
Test-
Unit
Terminal
equipment
Power meter Rear
ANT
panel
Deviation
Front
Modular
meter
panel
MIC jack
Oscilloscope
AG
AF VTVM
Adjustment
Unit
Parts
Method
Front
[ ],[ ] 2.10kHz
panel
(According to the
larger +, –)
4.20kHz
(According to the
larger +, –)
Check
Front
[ ],[ ] 0.35kHz
panel
0.75kHz
0.35kHz
0.75kHz
0.75kHz
1.00kHz
Specifications/Remarks
± 0.10kHz
± 0.10kHz
2.5~3.5kHz
± 0.05kHz
± 0.10kHz
± 0.05kHz
± 0.10kHz
± 0.10kHz
± 0.10kHz