Summary of Contents for Frigicoll Kaysun KCCHT-03

  • Page 1 OWNER'S MANUAL CONTROL KCCHT-03 Original instructions Thank you very much for purchasing our air conditioner, Before using your air conditioner, please read this manual carefully and keep it for future reference.
  • Page 3: Table Of Contents

    CONTENTS 1. Safety precautions.................1 2. Technical data and characteristic............1 3. Overview....................2 4. Operation instruction................5 5. Error handling..................17...
  • Page 4 • This manual gives detailed description of the precautions that should be brought to your attention during operation. • In order to ensure correct service of the wired controller please read this manual carefully before using the unit. • For convenience of future reference, keep this manual after reading it.
  • Page 5: Safety Precautions

    Safety precautions WARNING • Please assign the distributor or professionals to install the device. Improper insta- llation may lead to electric shock or fire. • Do not install the unit in a place vulnerable to leakage of flammable gases. Once flammable gases are leaked and left around the wire controller, fire may occur.
  • Page 6: Overview

    3. Overview MODE FUNCTIONS (Long press 3s for can- (Long press 3s for un- celling timing) locking) Operation icon Water Level Indica- OK Key Mode area tion (reserved) Function key Setting temperature Clock Add and Reduce key Timing On/Off Water temp. 10.ON/ Cancel key Function Icon OFF Key 11.Left / Right Key...
  • Page 7 Operation icon: Indicate unit ON and OFF status; the icon displays when the unit is on and does not display when the unit is off; Mode area: Indicate the main unit operating mode; details refer to Page 7; Water temperature: 2 status can be displayed: ; Timing ON/OFF indication: Indicate the timing information;...
  • Page 8 Water temperature: Under normal status display water temperature; Under water temperature setting status displays the setting value; Under check status displays check parameter, details refer to Page 8; ON/OFF key: Turn on and turn off functions, details refer to Page 6; Right and Left key: Press these keys to check setting water temperature;...
  • Page 9: Operation Instruction

    Operation instruction Turn On and Turn Off the main unit 1) Press the On/Off key to control On and Off status of the main unit. 2) Under Off status, press the On/Off key “ ” to run the main unit, at that time the LCD of wire controller will display the operation icon “...
  • Page 10 4.2 Setting operating mode and function parameters 4.2.1 Setting operating mode and water temperature 1) Setting operating mode Press “MODE” key to choose operation mode. The setting mode will change as the fo- llowing order each time the key is pressed: Press “OK”...
  • Page 11 (Long press 3s for (Long press 3s for Fig 4.3 unlocking) cancelling timing) Water temperature setting check: To check the water temprature setting vaule, press the “ ” or “ ” key under the main page(the page displayed after the controller is powered on). 4.2.2 Setting function parameters Press “FUNCTIONS”...
  • Page 12 (Long press 3s for (Long press 3s for Fig 4.5 unlocking) cancelling timing) 2) At this time the hour of the clock will flash, which means the current setting is the hour of Timer 1 “On”, press the “▲” or “▼” to adjust, press “ ► ” key when finished, and then the minute of the clock will flash, which means the current setting is the minute of Timer 1 “On”, press the “▲”...
  • Page 13 Fig 4.8 At this time the water temperture icon will flash, it means the current setting is the water tempera- ture, press the “▲” or “▼” to adjust, press “ ► ” key when finished,the LCD will display as the following: Fig 4.9 At this time the hour of the clock will flash, it means the current setting is the hour of the Timer 2 “On”.And the follow setting method will be the same as the Timer 1.
  • Page 14 Example of Timing setting Main page Press “FUNCTIONS” key twice to enter hour setting interface of “Timer 1 On” Press the “▲” or “▼” key to set the hour number of “Timing 1 On” to be 07 Press “ ” key to enter minute setting interface of “Timer 1 On”, adjust the minute number to be 10 Press “...
  • Page 15 During any period of timing setting to press “OK” key , the timing periods which have been set will be effective (only if the “On” and “Off” of one timing period have been set, the set- ting is effective). Check timing information: to check the timing which has been set, press “ ”...
  • Page 16 5)Set clock (Long press 3s for (Long press 3s for Fig 4.11 unlocking) cancelling timing) Press the “FUNCTIONS” key 3 times to enter clock setting. The hour of the clock will flash, which means the current setting is the hour of the clock, press the “▲” or “▼” to adjust, press “...
  • Page 17 Set unit number (Long press 3s for (Long press 3s for Fig 4.12 cancelling timing) unlocking) Press the “FUNCTIONS” key 4 times to enter the unit number setting. Press “▲” or “▼” to adjust the unit number. press “ OK ”key when finished or wait for 7 seconds to confirm. During the setting process pressing the “CANCEL”...
  • Page 18 Press the “FUNCTIONS” key 5 times to force open the water pump. The water pump icon will flash. Press “ OK ”key to confirm. During the setting process pressing the “CANCEL” key to re- turn to the main interface, and log off the forced water pump mode. NOTE a.
  • Page 19 4.5 Check Check function allows the user to check all the operating parameters, error and pro- tection information of the unit. Enter method: press and hold “FUNCTIONS” key for 3 seconds to enter check inter- face, as the figure display: (Long press 3s for (Long press 3s for Fig 4.14...
  • Page 20 Table 4-1 Meanings When in standby mode, water pump mode, displays water inlet tem- perature. In cooling and heating mode, displays the operating fre- quency. When defrosting, displays dF. when anti-freezing, displays Pb. when oil returning, displays d0. When remote controling,displays d8. Running model:0-shutdown,1-Pump mode,2-Cooling,3-Heating, 4-Forced cooling, 5-Forced heating.
  • Page 21: Error Handling

    Error handling When the unit has error or protection, “ ” icon will flash. If the “error” icon is on, it means the corresponding unit has error or protection at that time. The last 3 error or pro- tection codes of the unit can be checked. The error icon will disappear if the error or pro- tection is cleared.
  • Page 23 Version:MD14U-019BW 202055190106...