INSTALLATION
INSTRUCTIONS
The Lo Profile Deco Extractor & Humidity Range - LP / DECO 100, 120, 150
Switch off mains supply before making any electrical connections.
Installation must be supervised by a qualified electrician.
A double pole fused spur having contact separation of at least 3mm in
all pole must be used and fitted with a 3A fuse.
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory and mental capabilities or
lack of experience and knowledge if they have been given supervision
or instruction concerning the use of the appliance in a safe way and
understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
Precautions must be taken to avoid the back-flow of gases into the
room from the open flue of gas or other open-fire appliances when
mounted in outside windows or walls.
Fan must be disconnected from electrical power before any
maintenance is carried out.
Location
1. When installing fan through an external wall, an
external wall grille must be fitted at all times.
2. For best results this Extractor Fan should be fitted
as high on the wall as possible, or if preferred, on
the ceiling. Note: Pullcord models should not be
installed in a ceiling.
3. Where ducted fans are used to handle moisture-
laden air, such as a bathroom, a condensation
trap should be fitted in any vertical exhaust ducts.
Horizontal ducts should be arranged to slope
slightly away from the fan. Ducts passing through
cold voids must be suitably insulated.
4. Do not install the unit within a shower cubicle
or anywhere else where there is a risk of being
sprayed with water (Please see our range of
showerfans for these installations.).
5. If the fan is installed in a room containing a fuel
burning appliance, the installer must ensure that
the air replacement is adequate for both the fan
and the fuel burning appliance.
Wiring
1. Switch off mains supply before making electrical
connections. If in any doubt contact a qualified
electrician.
2. These units are for fixed wiring only. A flexible cord
must not be used. All wiring must be fixed securely
and the cable to the fan should be a minimum of
1mm
in section. All wiring must comply with current
2
I.E.E. Regulations or local regulations if outside the
UK.
3. A double pole fused spur having contact separation
of at least 3mm in all poles must be used and fitted
with a 3A fuse.
4. This fan is double insulated and does not require
an earth connection.
5. The fan should not be accessible to a person using
either the shower or the bath.

Advertisement

loading

Summary of Contents for Manrose LP 100

  • Page 1 INSTALLATION INSTRUCTIONS The Lo Profile Deco Extractor & Humidity Range - LP / DECO 100, 120, 150 Switch off mains supply before making any electrical connections. Installation must be supervised by a qualified electrician. A double pole fused spur having contact separation of at least 3mm in all pole must be used and fitted with a 3A fuse.
  • Page 2 INSTALLATION INSTRUCTIONS DECO fan only: Remove the screw on the 1. Cut a suitable diameter hole in the wall. If the fan bottom of the cover. Turn the cover anti is to be fixed in the ceiling ensure that the hole is clockwise to remove.
  • Page 3 Electrical Connection: Standard Model. See Diagram 1.Timer model, Diagram 2. Remove the internal cover by removing the 2 small caps and retaining Philips screws to access the terminal connections. The fan can either be operated from a separate pullcord switch fitted to the ceiling of the room or can be connected to the light switch so that the fan will start when the light is switched on.
  • Page 4 8. Electrical Connections: Electronic Humidity Model (Diagram 3) For the fan to operate as a normal time delay unit with humidity over-ride i.e. when connected with a switched live coming from the light switch into the fan, the fan will operate when the light is switched on, and switch off after about 20 seconds to 20 minutes (timer is pre-set for the minimum).

This manual is also suitable for:

Lp 120Lp 150Deco 100Deco 120Deco 150