1. SAFETY
WARNING:
The user must read and
understand all of the product
safety information prior to using
the JEFBATCHG3.5-612
Dynamo 3.5A Battery Charger.
• The JEFBATCHG3.5-612 has been
designed for charging all 6V and 12V lead-
acid batteries including; Wet (Flooded), Gel,
MF (Maintenance-Free), CA (Calcium),
EFB (Enhanced Flooded Battery), and AGM
(Absorption Glass Mat) batteries.
• Do not use this product to charge any
products outside of it's intended use.
• Before using the charger carefully read the
battery manufacturers specification,
precautions and recommended rates
of charge. Jefferson do not assume any
liability for misuse of this charger.
• Batteries contain explosive gases. Charging
should be carried out in a well ventilated
area and cool area away from sources of
heat flames and sparks.
• Indoor use only. This charger must not be
used outside in rain or snow conditions.
• Disconnect the mains cable. Before making
or breaking the connection to the battery
terminals, remove the plug from
the power supply.
• Connect the charger carefully. Make sure
the red clamp is attached to the battery
positive terminal. The black clamp attaches
to the negative. Do not reverse the clamps
or allow them to touch each other.
Please note this is not a jump start device!
FEATURES
Suitable for charging all 6V and 12V lead-acid batteries including; Wet (Flooded), Gel,
MF (Maintenance-Free), CA (Calcium), EFB (Enhanced Flooded Battery),
and AGM (Absorption Glass Mat) batteries
Suitable for charging battery capacities from 2 to 120 Ah and maintaining all battery sizes
Stabilises internal battery chemistry for increased performance and longevity
Four external holes for easy mounting
Supplied with 1.7 meter DC, 0.5 meter battery clamp and eyelet terminal connector
quick charge leads
• Refer to the vehicle manufacturers
information. Follow these instructions fully
to make sure no damage occurs to the
vehicle or it's equipment.
• Do not cover the charger. Allow air to
circulate around the charger to prevent
over heating.
• The charger is equipped with a time-lag
fuse inside. Over-heating will trip the fuse to
prevent damage and will not reset until
sufficiently cooled.
• Do not use the charger within the vehicle.
Stand it on a level firm surface to prevent
damage to the charger or vehicle.
• Do not tamper with this product. Repairs
and maintenance must be carried out by an
authorised service agent. Do not modify
this product in any way.
• Wear approved safety goggles (not safety
glasses) and latex/nitrile gloves. Before
charging a maintenance type battery the
electrolyte (battery acid) must be filled to
the maximum marked levels. Never use tap
water. Distilled water or electrolyte
must be used.
• Never attempt to charge non-rechargeable
batteries. Only charge lead acid batteries
within the voltage and amp hour capacities
of the charger.
• Never attempt to charge a frozen battery.
• Never attempt to charge a damaged or
distorted battery.
• Keep out of the reach of children.
www.jeffersontools.com
JEFBATCHG3.5-612
User Manual
2. CHARGING MODES
Mode
Explanation
Standby
In Standby mode, the charger
is not charging or providing
any power to the battery from
the mains power supply. When
selected a GREEN LED will
illuminate indicating
NO POWER.
12V 3.5A
For charging 12V Wet Cell,
NORM
Gel Cell, Enhanced Flooded,
Maintenance-free and Calcium
batteries. When selected, a
GREEN LED
will illuminate.
12V 3.5A
For charging 12V batteries in
COLD/
cold temperatures below 10°C
AGM
(50°F) or AGM batteries. When
selected a GREEN LED will
illuminate.
12V 1A
For charging 12V Wet Cell,
NORM
Gel Cell, Enhanced Flooded,
Maintenance-free and Calcium
batteries. When selected a BLUE
LED will illuminate.
12V 1A
For charging 12V batteries
COLD/
in cold temperatures below
AGM
10°C (50°F) or AGM batteries.
When selected a BLUE LED will
illuminate. 6V, 3.5A, for charging
6V wet cell, gel cell.
12V
An advanced battery recovery
REPAIR
mode for repairing and storing,
old, idle, damaged, stratified or
sultated batteries.
v.1.1
IP54 WATER
RESISTANT

Advertisement

loading

Summary of Contents for Jefferson Professional Tools & Equipment JEFBATCHG3.5-612

  • Page 1 • Do not cover the charger. Allow air to illuminate indicating circulate around the charger to prevent NO POWER. • The JEFBATCHG3.5-612 has been over heating. designed for charging all 6V and 12V lead- • The charger is equipped with a time-lag 12V 3.5A...
  • Page 2 JEFBATCHG3.5-612 User Manual v.1.1 2. CHARGING MODES (CONTINUED) 3. SPECIFICATION The JEFBATCHG3.5-612 Dynamo 3.5A Battery Charger Input Voltage: 220-240V, 50-60Hz, 0.8A has six modes: Standby, 12V/3.5A NORM, 12V/3.5A Efficiency: About 85% COLD/AGM, 12V/1A NORM, 12V/1A COLD/AGM, 12V REPAIR and 6V, 3.5A NORM.
  • Page 3 20H @ 14.7V 9. MOUNTING The JEFBATCHG3.5-612 Dynamo 3.5A Battery Charger has four external holes for mounting. Mount the charger in the desired location using the M3 self drill screws (supplied). • Ensure there are no obstructions behind the mounting surface.
  • Page 4 3 months after the initial sale to the distributor. Contact your Jefferson dealer or sales representative with the following information: 1 Year • Model number • Jefferson Dynamo 3.5A Battery Charger (JEFBATCHG3.5-612). • Serial number (usually located on the specification plate) • Date of purchase 90 Days •...